Centrifuges centrifugational number

The so-called centrifugational number is defined as the ratio of the centrifugal acceleration to the gravitational acceleration and may reach in technical centrifuges values of up to 4000 and in ultracentrifuges values of up to 10. ... [Pg.171]

For liquid-to-liquid separation, the centrifugal number may be as high as 60,000 for certain tubular sedimentation designs. The mining industry is concerned with wear, so slurries are separated at centrifugal numbers smaller than 100. [Pg.413]

There appear to be two stages in the collapse of emulsions flocculation, in which some clustering of emulsion droplets takes place, and coalescence, in which the number of distinct droplets decreases (see Refs. 31-33). Coalescence rates very likely depend primarily on the film-film surface chemical repulsion and on the degree of irreversibility of film desorption, as discussed. However, if emulsions are centrifuged, a compressed polyhedral structure similar to that of foams results [32-34]—see Section XIV-8—and coalescence may now take on mechanisms more related to those operative in the thinning of foams. [Pg.506]

Flow injection analysis (FIA) was developed in the mid-1970s as a highly efficient technique for the automated analyses of samples. °> Unlike the centrifugal analyzer described earlier in this chapter, in which samples are simultaneously analyzed in batches of limited size, FIA allows for the rapid, sequential analysis of an unlimited number of samples. FIA is one member of a class of techniques called continuous-flow analyzers, in which samples are introduced sequentially at regular intervals into a liquid carrier stream that transports the samples to the detector. ... [Pg.649]

The separation of cells from the culture media or fermentation broth is the first step in a bioproduct recovery sequence. Whereas centrifugation is common for recombinant bacterial cells (see Centrifugal separation), the final removal of CHO cells utilizes sterile-filtration techniques. Safety concerns with respect to contamination of the product with CHO cells were addressed by confirming the absence of cells in the product, and their relative noninfectivity with respect to immune competent rodents injected with a large number of CHO cells. [Pg.45]

Other Centrifugal Collectors. Cyclones and modified centrifugal collectors are often used to remove entrained Hquids from a gas stream. Cyclones for this purpose have been described (167—169). The rotary stream dust separator (170,171), a newer dry centrifugal collector with improved collection efficiency on particles down to 1—2 pm, is considered more expensive and hence has been found less attractive than cyclones unless improved collection in the 2—10-pm particle range is a necessity. A number of inertial centrifugal force devices as well as some others termed dynamic collectors have been described in the Hterature (170). [Pg.397]

Packed red cells are prepared from whole blood. These are collected ia blood coUectioa units having integrally attached transfer packs. The red cells are sedimented by centrifugation, and the plasma and huffy coat are expressed from the bag. Further processiag of the packed red cells may be needed for a number of clinical indications. To reduce the white blood cell (WBC) contamination in a red cell product, two separation techniques are used. [Pg.520]

Beckman Elutriation Method. The Beckman elutriation method uses a chamber designed so that the centrifugal effect of the radial inward fluid flow is constant (Fig. 3). The separation chambers are made of transparent epoxy resin which faciUtates observation of the movements of the cell boundary in strobe light illumination. This enables detection of the radius at which the cells are separating. When a mixture of cells, eg, mononuclear white cells, enters the chamber, separation can be achieved by fine tuning centrifuge speed and inward fluid flow to the specific cell group. This is a laboratory method suitable for relatively small numbers of cells. Chambers are available in sizes to handle 2-3 x 10 , 1 2 x 10 , and 1 x 10 ° cells. The Beckman chambers can be appHed to collect mononuclear cells from bone marrow aspirates. [Pg.522]

Most rotating equipment includes electric motors or steam dryers that generate noise at a constant frequency. Air cooler fans are a source of noise that can be reduced by lowering the fan speed and increasing the number of blades. Pump motor noise can be reduced by including a shroud or fan cover that is accurately lined. Centrifugal compressor noise reduction can be achieved by blade design and the use of compressor pulsation noise reduction, silencers, and vibration isolation. [Pg.83]

Efforts to develop an artificial heart have resulted in a number of advancements in the assist area. The centrifugal pump for open-heart surgery, the product of such an effort, has frequently been used to support patients after heart surgery (post-cardiotomy), or as a bridge to life prior to transplant. [Pg.181]

Under these circumstances, the settling motion of the particles and the axial motion of the Hquid phase are combined to determine the settling trajectory of these particles. The trajectory of particles just reaching the bowl wall near the point of Hquid discharge defines a minimum particle size that starts from an initial radial location and is separated in the centrifuge. A radius ris chosen to divide the Hquid annulus in the bowl into two equal volumes initially containing the same number of particles. Half the particles of size i present in the suspension are separated the other half escape. This is referred to as a 50% cutoff. [Pg.398]


See other pages where Centrifuges centrifugational number is mentioned: [Pg.429]    [Pg.430]    [Pg.430]    [Pg.429]    [Pg.430]    [Pg.430]    [Pg.386]    [Pg.836]    [Pg.838]    [Pg.844]    [Pg.88]    [Pg.231]    [Pg.206]    [Pg.636]    [Pg.116]    [Pg.417]    [Pg.408]    [Pg.408]    [Pg.34]    [Pg.72]    [Pg.93]    [Pg.103]    [Pg.109]    [Pg.520]    [Pg.529]    [Pg.310]    [Pg.431]    [Pg.92]    [Pg.513]    [Pg.182]    [Pg.56]    [Pg.397]    [Pg.398]    [Pg.399]    [Pg.401]    [Pg.404]    [Pg.409]    [Pg.409]   