Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Carbon amperometric

S. Sampath and O. Lev, Inert metal-modified, composite ceramic-carbon, amperometric biosensors renewable, controlled reactive layer. Anal. Chem. 68, 2015-2021 (1996). [Pg.550]

A dual electrochemical microchip detection system, based on the coupling of conductivity and amperometric detection schemes, was developed for simultaneous measurements of both nitroaromatic and ionic explosives [34], The microsystem relied on the combination of a contactless conductivity detector with an end-column thick-film carbon amperometric detector. Such ability to monitor both redox-active nitroaromatic and ionic explosives is demonstrated in Figure 13.7, which shows typical dual-detection electropherograms for a sample mixture containing the nitroaromatic explosives trinitrobenzene (TNB) (4), TNT (5), 2,4-DNB (6), and 2-Am-4,6-DNB (7), as well as the explosive-related ammonium... [Pg.270]

Glucose oxidase Graphene oxide modified glassy carbon Amperometric glucose biosensor [80]... [Pg.44]

Heller A 1990 Electrical wiring of redox enzyme Accounts Chem. Res. 23 128-34 Wang J, Lu F, Angnes L, Liu J, Sakslund H, Chen Q, Pedrero M, Chen L and Hammerich O 1995 Remarkably selective metallized-carbon amperometric biosensors Anal. Chim. Acta 305 3-7... [Pg.143]

Bratin K, Kissinger PT. Glassy-carbon amperometric transducers as electrochemical detectors in liquid chromatography The influence of oxygen. Talanta 1982 29 365-70. [Pg.606]

Sampath S., Lev O. Inert metal-modified, composite ceramic-carbon, amperometric biosensors Renewable, controlled reactive layer. Anal. Chem. 1996a 68 2015-2021 Sampath S., Pankratov I., Gun J., Lev O. Sol-gel derived ceramic carbon-enzyme electrodes. J. Sol-Gel Sci. Technol. 1996 7 123-128... [Pg.502]

For selective estimation of phenols pollution of environment such chromatographic methods as gas chromatography with flame-ionization detector (ISO method 8165) and high performance liquid chromatography with UV-detector (EPA method 625) is recommended. For determination of phenol, cresols, chlorophenols in environmental samples application of HPLC with amperometric detector is perspective. Phenols and chlorophenols can be easy oxidized and determined with high sensitivity on carbon-glass electrode. [Pg.129]

FIGURE 3-21 Typical amperometric readout during automated flow injection assays of ethanol at an enzyme carbon-paste electrode. Peaks a through h 2 x 10 5 M to 1.6 x 10 4 M ethanol. [Pg.87]

FIGURE 3-23 Schematic of a carbon-fiber amperometric detector for capillary electrophoresis A, fused silica capillary B, eluent drop C, stainless steel plate RE, reference electrode WE, working electrode, AE, auxiliary electrode. (Reproduced with permission from reference 58.)... [Pg.89]

FIGURE 3-27 Three-dimensional chromatogram for oxidizable biological compounds at a multichannel amperometric detection system, consisting of an array of 16 carbon-paste electrodes held at different potentials. AA = ascorbic acid NE = norepinephrine DOPAC = 3,4-dihydroxyphenylacetic acid 5-HIAA = 5-hydroxyindole-3-acetic acid DA = dopamine HVA = homovanillic acid. (Reproduced with permission from reference 68.)... [Pg.94]

Other usefiil gas sensors include the potentiometric ammonia (64) or hydrogen cyanide probes (65), and amperometric carbon monoxide (66) and nitrogen dioxide (67) devices. The hydrogen cyanide probe is an example of a modem device that relies on changes in the conductivity of electropolymerized film (polyanihne) in the presence of a given gas. [Pg.191]

FIGURE 6-24 Response pattern of an amperometric sensor array for various carbohydrates. The array comprised carbon-paste electrodes doped with CoO (1), Cu20 (2), NiO (3) and Ru02 (4). (Reproduced with permission from reference 84.)... [Pg.197]

Hence the slope of the plot of log[S] against log[M] must equal Cs-The concentration [S] of unreacted mercaptan regulator may be determined by amperometric titration with silver nitrate,or the combined sulfur in the polymer may be determined radiochemically using mercaptan containing S, and the unreacted mercaptan concentration [S] calculated by difference. Transfer constants for carbon... [Pg.147]

F.-C. Gong, X.-B. Zhang, C.-C. Guo, G.-L. Shen, and R.-Q. Yu, Amperometric metronidazole sensor based on the supramolecular recognition by metallopor-phyrin incorporated in carbon paste electrode, Sensors, 3 (2004) 91-100. [Pg.368]

J. Katrlik and P. Zalesakova, Nitric oxide determination by amperometric carbon fiber microelectrode. Bioelectrochemistry 56, 73-76 (2002). [Pg.49]

V.B. Kandimalla and H.X. Ju, Binding of acetylcholinesterase to multiwall carbon nanotube-cross-linked chitosan composite for flow-injection amperometric detection of an organophosphorous insecticide. Chem. Eur. J. 12, 1074—1080 (2006). [Pg.73]

A.A. Ciucu, C. Negulescu, and R.P. Baldwin, Detection of pesticides using an amperometric biosensor based on ferophthalocyanine chemically modified carbon paste electrode and immobilized bienzymatic system. Biosens. Bioelectron. 18, 303-310 (2003). [Pg.78]


See other pages where Carbon amperometric is mentioned: [Pg.49]    [Pg.49]    [Pg.49]    [Pg.49]    [Pg.49]    [Pg.1541]    [Pg.49]    [Pg.49]    [Pg.49]    [Pg.49]    [Pg.49]    [Pg.1541]    [Pg.34]    [Pg.1940]    [Pg.103]    [Pg.103]    [Pg.57]    [Pg.121]    [Pg.127]    [Pg.172]    [Pg.173]    [Pg.180]    [Pg.135]    [Pg.136]    [Pg.407]    [Pg.267]    [Pg.95]    [Pg.221]    [Pg.670]    [Pg.360]    [Pg.68]    [Pg.195]    [Pg.495]    [Pg.30]    [Pg.56]    [Pg.59]    [Pg.60]    [Pg.149]   
See also in sourсe #XX -- [ Pg.2 , Pg.300 ]




SEARCH