Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Capillary electrophoresis requirements

Most types of electrophoresis using supporting media are simple to carry out and the apparatus can be easily constructed, although inexpensive equipment is commercially available. High-resolution techniques such as two-dimensional electrophoresis and capillary electrophoresis require more sophisticated equipment, both for separation and analysis (see later). [Pg.225]

Most of the commonly used methods of inorganic analysis of plastics, including inductively coupled plasma emission spectroscopy, atomic absorption spectroscopy, ionic chromatography, and capillary electrophoresis, require that the samples for analyses be introduced preferably as solutions with low viscosity and minimal salt content. [Pg.545]

Identification of stmctures of toxic chemicals in environmental samples requires to use modern analytical methods, such as gas chromatography (GC) with element selective detectors (NPD, FPD, AED), capillary electrophoresis (CE) for screening purposes, gas chromatography/mass-spectrometry (GC/MS), gas chromatography / Fourier transform infra red spectrometry (GC/FTIR), nucleai magnetic resonance (NMR), etc. [Pg.416]

At present moment, no generally feasible method exists for the large-scale production of optically pure products. Although for the separation of virtually every racemic mixture an analytical method is available (gas chromatography, liquid chromatography or capillary electrophoresis), this is not the case for the separation of racemic mixtures on an industrial scale. The most widely applied method for the separation of racemic mixtures is diastereomeric salt crystallization [1]. However, this usually requires many steps, making the process complicated and inducing considerable losses of valuable product. In order to avoid the problems associated with diastereomeric salt crystallization, membrane-based processes may be considered as a viable alternative. [Pg.126]

To allow all culture productiou to be coutrolled, a method for rapid analysis is required. Prior to development of an LC-MS method, the analysis was both complex and time-consuming, involving the purification of a relatively large amount of the antibody using affinity chromatography, enzymatic release, and subsequent derivatizafion of the oligosaccharides and their analysis by using capillary electrophoresis. [Pg.202]

Sulfonylureas are not directly amenable to gas chromatography (GC) because of their extremely low volatility and thermal instability. GC has been used in conjunction with diazomethane derivatization, pentafluorobenzyl bromide derivatization, and hydrolysis followed by analysis of the aryl sulfonamides. These approaches have not become widely accepted, owing to poor performance for the entire family of sulfonylureas. Capillary electrophoresis (CE) has been evaluated for water analysis and soil analysis. The low injection volumes required in CE may not yield the required sensitivity for certain applications. Enzyme immunoassay has been reported for chlorsulfuron and triasulfuron, with a limit of detection (LOD) ranging from 20 to 100 ng kg (ppt) in soil and water. [Pg.400]

Several additional instrumental techniques have also been developed for bacterial characterization. Capillary electrophoresis of bacteria, which requires little sample preparation,42 is possible because most bacteria act as colloidal particles in suspension and can be separated by their electrical charge. Capillary electrophoresis provides information that may be useful for identification. Flow cytometry also can be used to identify and separate individual cells in a mixture.11,42 Infrared spectroscopy has been used to characterize bacteria caught on transparent filters.113 Fourier-transform infrared (FTIR) spectroscopy, with linear discriminant analysis and artificial neural networks, has been adapted for identifying foodbome bacteria25,113 and pathogenic bacteria in the blood.5... [Pg.12]

Two-dimensional capillary electrophoresis of complex protein samples requires careful attention to detail. Tissues and cells should be fixed to prevent degradation. Most conventional fixatives are inappropriate because they produce covalent crosslinks, which are difficult to reverse. We find that ethanol produces decent results when the sample is homogenized with high concentrations of SDS. [Pg.360]

Identification and quantification of natural dyes need high performance analytical techniques, appropriate for the analysis of materials of complicated matrices containing a small amount of coloured substances. This requirement perfectly fits coupling of modern separation modules (usually high performance liquid chromatography in reversed phase mode, RPLC, but also capillary electrophoresis, CE) with selective detection units (mainly mass spectrometer). [Pg.365]

In analytical chemistry there is an ever-increasing demand for rapid, sensitive, low-cost, and selective detection methods. When POCL has been employed as a detection method in combination with separation techniques, it has been shown to meet many of these requirements. Since 1977, when the first application dealing with detection of fluorophores was published [60], numerous articles have appeared in the literature [6-8], However, significant problems are still encountered with derivatization reactions, as outlined earlier. Consequently, improvements in the efficiency of labeling reactions will ultimately lead to significant improvements in the detection of these analytes by the POCL reaction. A promising trend is to apply this sensitive chemistry in other techniques, e.g., in supercritical fluid chromatography [186] and capillary electrophoresis [56-59], An alter-... [Pg.166]

Many of the more established techniques have been validated through collaborative studies which becomes of greater importance as laboratories seek to become accredited via ISO, EN or related systems where the use of official or well validated methods is mandatory. New instrumental techniques are constantly being reported in the literature but it often requires many years before procedures are introduced, validated and then applied within the food industry. Recent techniques that can be included in this category are capillary electrophoresis and liquid chromatography-mass spectrometry (LC-MS). In time procedures based on these techniques will also become accepted as routine methods and are likely to be adopted by some of the official international bodies like the AOAC International, CEN, ISO, etc. [Pg.112]


See other pages where Capillary electrophoresis requirements is mentioned: [Pg.163]    [Pg.87]    [Pg.375]    [Pg.192]    [Pg.229]    [Pg.455]    [Pg.163]    [Pg.140]    [Pg.163]    [Pg.87]    [Pg.375]    [Pg.192]    [Pg.229]    [Pg.455]    [Pg.163]    [Pg.140]    [Pg.609]    [Pg.277]    [Pg.183]    [Pg.278]    [Pg.501]    [Pg.198]    [Pg.321]    [Pg.542]    [Pg.147]    [Pg.55]    [Pg.263]    [Pg.779]    [Pg.22]    [Pg.414]    [Pg.275]    [Pg.544]    [Pg.16]    [Pg.330]    [Pg.240]    [Pg.113]    [Pg.465]    [Pg.588]    [Pg.71]    [Pg.184]    [Pg.368]    [Pg.369]    [Pg.476]    [Pg.476]   
See also in sourсe #XX -- [ Pg.297 ]




SEARCH



© 2024 chempedia.info