Capillaries maximum allowed length

The maximum allowed length of a connecting capillary between the injector, column and detector is defined as ... [Pg.368]

General aspects of extra-column volumes in the HPLC instrument have been discussed in Section 2.6. Various formulas have been proposed which allow to calculate the maximum allowed capillary length with regard to band broadening an adaption after M. Martin et al. is as follows ... [Pg.70]

PEO, pDMA, and polyvinylpyrrolidone (PVP) have self-coating abilities, which allows DNA sequencing in bare fused-silica capillaries. A mixture of two molecular mass populations of PEO is possible to separate DNA sequencing fragments over 1000 bases, too, but the separation time exceeds 7 hr. pDMA and PVP are low-viscosity sieving matrices (<100 cP). They have moderate separation efficiencies and can provide maximum read lengths of about 500-600 bases. [Pg.630]

Capillary cassettes designed for CE-MS allow capillaries to exit the instrument. They generally present a UV detection window at a short distance from the inlet position. The total length of the capillary varies from 120 to 60 cm if the UV detection is by-passed. In this case, maximum field strength is available but does not allow simultaneous UV and MS detection. [Pg.276]

The instrumentation required to perform FCCE is relatively simple. The power supply can be any commercially available HVDC power source, but an ideal power supply would have dual polarity, 0-30 kV at several 100 elA, with safety interlocks and computer control capabilities. The maximum voltage needed is determined by the desired electric field strength and length of the capillary. In order to allow for some margin of error in control of the counter flow, the minimum length of capillary should be at least three to four times the physical width of the desired separation window. These margins allow for the analyte bands to be maintained within the inner half of the capillary so that they are not pushed out on either side of the capillary, with detection occurring in the center of the capillary. [Pg.738]

In 1987, Hjerten and co-workers [39] first demonstrated the possibility of performing isoelectric focusing and molecular sieving in capillary tubes. Gels are potentially useful for electrophoretic separations because they are anticonvective media they minimize solute diffusion, which contributes to zone broadening they prevent solute absorption to the capillary walls and they eliminate electro-osmosis, thus allowing maximum resolution in short column lengths. [Pg.517]

A tubular reactor setup was developed for the synthesis of the above-mentioned model copolymer for acrylic binder materials. The tuhular reactor essentially consists of capillaries with an internal diameter of 3.8 mm and a length of either 4 or 8 m, which are wound up to a coil of 15 cm diameter. The two reactor lengths allow for adjusting residence times between 5.5 and 44 min. The maximum pressure of the setup is 500 hat at 200 Typically, a premixed solution containing the... [Pg.893]


See other pages where Capillaries maximum allowed length is mentioned: [Pg.110]    [Pg.528]    [Pg.218]    [Pg.190]    [Pg.140]    [Pg.213]    [Pg.418]    [Pg.919]    [Pg.683]    [Pg.133]    [Pg.131]    [Pg.294]    [Pg.688]    [Pg.134]    [Pg.299]    [Pg.300]    [Pg.60]    [Pg.127]    [Pg.33]    [Pg.229]    [Pg.18]    [Pg.4343]    [Pg.203]    [Pg.1958]    [Pg.132]    [Pg.124]    [Pg.95]   
See also in sourсe #XX -- [ Pg.70 , Pg.368 ]

See also in sourсe #XX -- [ Pg.63 , Pg.325 ]