Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Baseline, analysis. conditions

The baseline reactor conditions in the following reactor analysis are susceptor temperature Ts = 1273 K, inlet temperature Tm = 333 K, reactor pressure p = 400 mTorr, gas velocity through the inlet manifold Vin = 100 cm/s, and the gap between inlet and susceptor L = 1 cm. Incoming gas-mixture mole fractions (e.g., from a gas-cylinder) are TEOS 0.25 and N2 (carrier gas) 0.75. You may use the files teos. gas and teos. surf for the gas-phase and surface reaction mechanisms. (Hint You may need the following initial guesses at the surface species site fractions SiG3(OH) 0.98, SiGsE 0.02, SiG(OH)2E 0.001. More details on the surface reaction mechanism and nomenclature are found in Ref. [69].)... [Pg.728]

Near baseline resolution of the two diastereoisomers of soman can be obtained on nonpolar columns under normal analysis conditions and complete resolution can be obtained on more polar columns such as poly (ethylene glycol) Chiral resolution of the four iso-... [Pg.814]

Comparative analysis directly compares two or more data sets in order to detect changes in the operating condition of mechanical or process systems. This type of analysis is limited to the direct comparison of the time-domain or frequency-domain signature generated by a machine. The method does not determine the actual dynamics of the system. Typically, the following data are used for this purpose (1) baseline data, (2) known machine condition, or (3) industrial reference data. [Pg.692]

When using this type of comparative analysis, the analyst compares the vibration energy and profile from a suspect machine to that of a machine with known operating condition. For example, the suspect machine can be compared to the baseline reference taken from a similar machine within the plant. Or, a machine profile with a known defect. [Pg.693]

This technique acquires overall or broadband vibration readings from select points on a machine-train. This data is compared to either a baseline reading taken from a new machine or to vibration severity charts to determine the relative condition of the machine. Normally an unfiltered broadband measurement that provides the total vibration energy between 10 and 10,000 Hertz is used for this type of analysis. [Pg.798]

Electrolysis of mobile phase constituents will cause a continuous detector response (background current) resulting in a chromatographic baseline level that differs from the electrical detector zero-response level. The difference, baseline- offset, is an important analysis parameter, because baseline fluctuations (noise, drift) due to fluctuations in electrolysis conditions (potential, mobile phase flow rate, temperature) are proportional to baseline offset. See Figure 2-5 for an example of the influence of flow pulsation at different baseline offset... [Pg.16]

A challenge for security vulnerability analysis is that the accurate prediction of the frequency and location of terrorist acts is not considered credible. As such, the analyst has a choice of assuming a frequency of a certain attack or assuming the attack frequency is 1, thereby focusing solely on the conditional likelihood of success of the adversary who attempts an attack. While the latter approach provides a baseline for making decisions about vulnerability, it does not fully... [Pg.107]

FIGURE 3.14 Electrochromatograms of mebeverine on Chiralcel OD-RH at screening conditions and after application of the proposed optimization 2 when a baseline resolntion is achieved at screening conditions (Rs Resolntion, AT Analysis Time). [Pg.204]

Coumarins are pharmacologically active and have been used in the treatment of a diverse range of diseases. The great diversity of coumarin structures and their wide range of polarities present special problems for their simultaneous analysis. The separation of seven closely related coumarins by CZE was studied. Optimized conditions tallied with a 200 mM boric acid—50 mM tetraborate buffer pH 8.5 and were applied to the determination of coumarins in extracts from roots and aerial parts from the plant Chrysanthemum segetum. Baseline separation of six coumarins was achieved in 10 min. [Pg.279]

Performance tests executed under at-rest (complete and with production equipment installed and operating, but without personnel within the facility) conditions will serve as baseline information, and are needed to determine simulated fully operational conditions. After this analysis certain procedures, equipment, methods, etc., are changed. [Pg.166]

Tests performed under at-rest conditions to serve as baseline information are needed to determine the degree by which the environmental parameters are affected by the process after they are repeated at dynamic conditions (simulated fully operational conditions). After this analysis, review procedures, equipment, methods, etc. and change if necessary. Performance tests executed at dynamic conditions are the only way to obtain a clean representation of the prevailing environmental conditions. [Pg.990]

The conditions of IC analysis (Table I) chosen were based on the need for separation of formate ion from common atmospheric contaminants, such as chloride ion, and other organic anions, such as acetate. The conditions were also optimized to obtain a suitable detection limit. Thus, a weak borate eluent (0.005 combined with a 500 mm anion separator column (and a 150 mm precolumn) was chosen. Conversion of the pre-column and separator column to their borate forms (from the normal carbonate form) was necessary. The process of continually passing the borate eluent through the columns until a stable baseline was obtained required several hours. [Pg.601]

A frequently discussed question is whether either system suitability testing or the analysis of QC samples are sufficient to prove ongoing system performance, or whether additional checks should be performed. The answer to this question depends very much on the conditions under which the control samples are analyzed. For example, if the system is used for trace analysis and the amounts of the control sample do not include trace-level amounts, the capability of the system to measure low amounts should be verified. In HPLC, this could be a routine check of the wavelength accuracy, the baseline noise, and the intensity of the UV lamp. System suitability checks and control sample analysis are sufficient as PQ checks if all critical system parameters are checked as part of tests and evaluations. [Pg.264]

This CE method provides an efficient approach for rapid and effective separation of serum conjugated BAs with an analysis time of 8 min. It is important to mention that each micellar solution plays an important role in the analysis use of 20 mM SDS is to modify the electro-osmotic flow, whereas solubility of glycine-conjugated BAs and the peak shape of all BAs are maintained with 20% acetonitrile and the neutral pH of the phosphate buffer. The optimum condition for baseline separation is achieved with the addition of 8 mM CD. [Pg.637]


See other pages where Baseline, analysis. conditions is mentioned: [Pg.274]    [Pg.304]    [Pg.340]    [Pg.18]    [Pg.227]    [Pg.30]    [Pg.49]    [Pg.1152]    [Pg.44]    [Pg.435]    [Pg.379]    [Pg.341]    [Pg.105]    [Pg.122]    [Pg.99]    [Pg.189]    [Pg.507]    [Pg.60]    [Pg.112]    [Pg.198]    [Pg.200]    [Pg.219]    [Pg.29]    [Pg.486]    [Pg.262]    [Pg.268]    [Pg.277]    [Pg.279]    [Pg.489]    [Pg.534]    [Pg.57]    [Pg.236]    [Pg.37]    [Pg.495]    [Pg.235]    [Pg.391]   
See also in sourсe #XX -- [ Pg.112 , Pg.113 , Pg.114 , Pg.115 ]




SEARCH



Baseline

Baseline condition

© 2024 chempedia.info