Fluctuations, baseline

Electrolysis of mobile phase constituents will cause a continuous detector response (background current) resulting in a chromatographic baseline level that differs from the electrical detector zero-response level. The difference, baseline- offset, is an important analysis parameter, because baseline fluctuations (noise, drift) due to fluctuations in electrolysis conditions (potential, mobile phase flow rate, temperature) are proportional to baseline offset. See Figure 2-5 for an example of the influence of flow pulsation at different baseline offset... [Pg.16]

Inlet and outlet check valves ensure a one-way solvent flow. Problems arise when the plunger must be pulled back to refill the chamber to ready itself for the next stroke (Fig. 9.3). The pressure drops until the plunger starts forward again. This results in pulsation, which causes variations in solvent delivery flow and, more importantly, variation in pressure to the column. The column acts as a pressure dampener, which can easily seen by watching baseline fluctuation of a system with and without a column in place. [Pg.108]

Perhaps, the simplest method for minimizing sample-induced spectral baseline fluctuations is by calculating derivative (first, second, etc.) spectra. In derivative spectra, broad baseline fluctuations have much smaller slopes and curvatures than vibrational absorption bands in the original spectra, and as a consequence, the resulting derivative spectra have diminished broader features. This effect is seen in the Fig. 4.6,... [Pg.93]

A number of innovations in FFF design have been introduced recently which have improved resolution and sensitivity and reduced the major obstacles to automation. The introduction of cross-flow recirculation has resulted in better control of system pressures, thereby reducing baseline fluctuation and improving reproducibility [6]. The incorporation of a frit inlet (FI) into the flow FFF channel has permitted the use of hydrodynamic relaxation as a replacement for stop-flow relaxation, thus eliminating pressure fluctuations associated with the latter [7]. FI also reduces sample adhesion to the membrane on the accumulation wall, thereby reducing the likelihood of baseline drift and artifacts [7]. [Pg.1729]

Figure 10.16. Baseline fluctuations from blending 0.1% TFA in water and 0.1% TFA in ACN vs. that of 0.05% TFA in water and 0.03% TFA in ACN at different wavelengths (210, 230, and 258 nm). The magnitude of baseline noise is dependent on monitoring wavelength and is caused by pump blending and the absorbance of TFA. Figure 10.16. Baseline fluctuations from blending 0.1% TFA in water and 0.1% TFA in ACN vs. that of 0.05% TFA in water and 0.03% TFA in ACN at different wavelengths (210, 230, and 258 nm). The magnitude of baseline noise is dependent on monitoring wavelength and is caused by pump blending and the absorbance of TFA.
Rg. 3.11. Peak-to-peak noise level as a basis for detection limit. The background fluctuations represent continuously recorded background signals, with the analyte measurement represented by the peak signal. A detectable analyte signal would be 12 divisions above a line dravra through the average of the baseline fluctuations. [Pg.112]

Number of phases indicates the complexity of the MUP and the degree of misalignment between SFAPs. In neurogenic diseases, polyphasic MUPs arise due to slow conduction velocity in immature nerve sprouts or slow conduction velocity in reinnervated but still atrophied muscle fibers. Variation in muscle fiber size also causes polyphasic MUPs in myopathic diseases. To prevent noisy baseline fluctuations from affecting the count of MUP phases, a valid baseline crossing must exceed a minimum absolute amplitude criterion. [Pg.410]

The interpretation of two-dimensional correlation maps can be comphcated by noise and baseline fluctuations [287a] or by perturbation-induced changes in the band frequency, FWHM, and oscillator strength [288]. Specific complications arise when applying 2DIR correlation analysis to the IRRAS of monolayers at the air-water interface [284],... [Pg.219]

In IC, fluorescence detection is rarely used as a detection method since very few ions fluoresce. Refractive index detection is a non-selective detection. Only because of its moderate sensitivity, vay poor selectivity, and sensitivity to baseline fluctuations, it is very rarely used in IC. The only advantage of refractive index detection is the ability to use comparatively concentrated eluants that allow the use of high-capacity ion exchangers. ... [Pg.578]

Electrodes in poor condition give rise to artefact pulses, baseline fluctuations and background noise. [Pg.45]

To meet the demand arising from high resolution spectroscopy, a considerable improvement has been introduced on the built-in base-line restorers and pile-up rejectors in order to avoid spectral distortions that may arise from baseline fluctuations at high counting rates and from pulse-on-pulse pile-up. [Pg.134]


See other pages where Fluctuations, baseline is mentioned: [Pg.234]    [Pg.376]    [Pg.386]    [Pg.31]    [Pg.376]    [Pg.510]    [Pg.251]    [Pg.204]    [Pg.695]    [Pg.413]    [Pg.92]    [Pg.94]    [Pg.96]    [Pg.107]    [Pg.179]    [Pg.82]    [Pg.125]    [Pg.146]    [Pg.258]    [Pg.499]    [Pg.67]    [Pg.68]    [Pg.367]    [Pg.335]    [Pg.288]    [Pg.74]    [Pg.1363]    [Pg.463]    [Pg.53]    [Pg.47]    [Pg.51]    [Pg.52]   
See also in sourсe #XX -- [ Pg.361 , Pg.386 ]




SEARCH



Baseline

Fluctuations, baseline variations

Heat baseline fluctuations