Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Anti-stokes Raman spectroscopy

COHERENT ANTI-STOKES RAMAN SPECTROSCOPY (CARS)... [Pg.260]

Our first example of aP - signal is coherent anti-Stokes Raman spectroscopy, or CARS. Fomially, tire emission signal into direction k= - k + k. has 48 Feynman diagrams that contribute. Flowever, if the... [Pg.260]

Knopp G, Pinkas I and Prior Y 2000 Two-dimensional time-delayed coherent anti-Stokes Raman spectroscopy and wavepacket dynamics of high ground-state vibrations J. Raman Spectrosc. 31 51... [Pg.280]

Oudar J-L, Smith R W and Shen Y R 1979 Polarization-sensitive coherent anti-Stokes Raman spectroscopy Appi. Rhys. Lett. 34 758-60... [Pg.1229]

Joe T and Albrecht A C 1993 Femtosecond time-resolved coherent anti-Stokes Raman spectroscopy of liquid benzene a Kubo relaxation function analysis J. Chem. Phys. 99 3244-51... [Pg.1230]

Gross L P, Trump D D, MacDonald B G and Switzer G L 1983 10-Hz coherent anti-Stokes Raman spectroscopy apparatus for turbulent combustion studies Rev. Sc/. Instrum. 54 563-71... [Pg.1232]

Coherent anti-Stokes Raman spectroscopy (CARS) [59] has also found utility in the detemiination of the internal state distributions of products of chemical reactions. This is one of several coherent Raman spectroscopies based on the... [Pg.2084]

CARS. See Coherent anti-Stokes Raman spectroscopy. [Pg.170]

An interesting variation of Raman spectroscopy is coherent anti-Stokes Raman spectroscopy (CARS) (99). If two laser beams, with angular frequencies CO and CO2 are combined in a material, and if cjj — is close to a Raman active frequency of the material, then radiation at a new frequency CJ3 = 2cJ2 — may be produced. Detection of this radiation can be used to characterize the material. Often one input frequency is fixed and the other frequency, from a tunable laser, varied until matches the Raman frequency. CARS has the capabiHty for measurements in flames, plasmas, and... [Pg.17]

Koszykowski M. L., Farrow R. L., Palmer R. E. Calculation of collisionally narrowed coherent anti-Stokes Raman spectroscopy spectra, Opt. Lett. 10, 478-80 (1985). [Pg.291]

K. Kneipp, H. Kneipp, P. Corio, S.D.M. Brown, K. Shafer, J. Motz, L.T. Perelman, E.B. Hanlon, A. Marucci, G. Dresselhaus, and M.S. Dresslhaus, Surface-enhanced and normal stokes and anti-stokes Raman spectroscopy of single-walled carbon nanotubes. Phys. Rev. Lett. 84, 3470-3473 (2000). [Pg.523]

Peyser-Capadona L, Zheng J, Gonzalez JI, Lee T-H, Patel SA, Dickson RM (2005) Nanopar-ticle-free single molecule anti-stokes Raman spectroscopy. Phys Rev Ixtt 94 058301... [Pg.331]

Early picosecond studies were carried out by Schneider et al, [63] on the parent spiro-oxazine (NOSH in Scheme 8) and similar derivatives. In a back-to-back work, they also described a complimentary CARS (coherent anti-Stokes Raman spectroscopy) investigation [69], Simply put, these authors found that the closed spiro-oxazine ring opened in 2-12 psec after laser excitation. The reaction was slower in more viscous solvents. An intermediate state formed within the excitation pulse and preceded the formation of merocyanine forms. This transient was named X in deference to the X transient named by Heiligman-Rim et al. for the spiropyran primary photoproduct [8], (See also the previous section.) The name X has since been adopted by other workers for the spiro-oxazines [26,65],... [Pg.368]

Dudovich, N., Oron, D., and Silberberg, Y. 2003. Single-pulse coherent anti-Stokes Raman spectroscopy in the fingerprint spectral region. J. Chem. Phys. 118 9208-15. [Pg.161]

Petrov, G. 1., Yakovlev, V. V., Sokolov, A., and Scully, M. O. 2005. Detection of Bacillus subti-lis spores in water by means of broadband coherent anti-Stokes Raman spectroscopy. Opt. Express 13 9537 2. [Pg.164]

Several types of time-resolved Raman spectroscopies have been reported and reviewed by Hamaguchi and co-workers and Hamaguchi and Gustafson. These include pump-probe spontaneous and time-resolved coherent Raman spectroscopy of the anti-Stokes and Stokes varieties [coherent anti-Stokes Raman spectroscopy (CARS) and coherent Stokes Raman spectroscopy (CSRS)], respectively). Here we will focus on pump-probe time-resolved spontaneous Raman spectroscopy. [Pg.881]

Capadona, L.P., J. Zheng, J.I. Gonzalez, T.-H. Lee, S.A. Patel, and R.M. Dickson. 2005. Nanoparticle-free single molecule anti-Stokes Raman spectroscopy. Phys.I Rev. Lett. 94) 058301. [Pg.165]

As I have indicated, this presentation will be divided into two parts. In the first part we will discuss the development of Coherent Anti-Stokes Raman Spectroscopy, the problems inherent in applications to combustion sources, recent developments which address operational problems, and the state-of-the-art today. This will be followed by a similar discussion involving the use of saturated laser-induced fluorescence spectroscopy as a combustion diagnostic. [Pg.19]

The inelastic processes - spontaneous Raman scattering (usually simply called Raman scattering), nonlinear Raman processes, and fluorescence - permit determination of species densities as well as temperature, and also allow one, in principle, to determine the temperature for particular species whether or not in thermal equilibrium. In Table II, we categorize these inelastic processes by the type of the information that they yield, and indicate the types of combustion sources that can be probed as well as an estimate of the status of the method. The work that we concentrate upon here is that indicated in these first two categories, viz., temperature and major species densities determined from vibrational Raman scattering data. The other methods - fluorescence and nonlinear processes such as coherent anti-Stokes Raman spectroscopy - are discussed in detail elsewhere (5). [Pg.209]

Table II Space- and Time-Resolved Measurements from Inelastic Light Scattering. All methods are suitable for nonequilibrium conditions. Here, RS refers to Raman scattering, CARS to coherent anti-Stokes Raman spectroscopy, and RIKES to Raman-induced Kerr effect. Table II Space- and Time-Resolved Measurements from Inelastic Light Scattering. All methods are suitable for nonequilibrium conditions. Here, RS refers to Raman scattering, CARS to coherent anti-Stokes Raman spectroscopy, and RIKES to Raman-induced Kerr effect.
Two techniques, which appear well suited to the diagnostic probing of practical flames with good spatial and temporal resolution, are coherent anti-Stokes Raman spectroscopy (CARS) and saturated laser fluorescence. The two techniques are complementary in regard to their measurement capabilities. CARS appears most appropriate for thermometry and major species concentration measurements, saturated laser fluorescence to trace radical concentrations. With electronic resonant enhancement (6), CARS may be potentially useful for the latter as well. Fluorescence thermometry is also possible (7, 8) but generally, is more tedious to use than CARS. In this paper, recent research investi-... [Pg.271]


See other pages where Anti-stokes Raman spectroscopy is mentioned: [Pg.244]    [Pg.237]    [Pg.318]    [Pg.431]    [Pg.4]    [Pg.151]    [Pg.34]    [Pg.244]    [Pg.24]    [Pg.237]    [Pg.3]    [Pg.288]    [Pg.19]    [Pg.20]    [Pg.231]    [Pg.272]   


SEARCH



Anti-stokes

Raman anti-Stokes

© 2024 chempedia.info