Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical methods constrained

A simple, time-honoured illustration of the operation of the Monte Carlo approach is one curious way of estimating the constant n. Imagine a circle inscribed inside a square of side a, and use a table of random numbers to determine the cartesian coordinates of many points constrained to lie anywhere at random within the square. The ratio of the number of points that lies inside the circle to the total number of points within the square na l4a = nl4. The more random points have been put in place, the more accurate will be the value thus obtained. Of course, such a procedure would make no sense, since n can be obtained to any desired accuracy by the summation of a mathematical series... i.e., analytically. But once the simulator is faced with a eomplex series of particle movements, analytical methods quickly become impracticable and simulation, with time steps included, is literally the only possible approach. That is how computer simulation began. [Pg.466]

In dibenzothiophene-S,S-dioxide the S atom is in a ring, and hence more constrained. The yield of SOz in the radiolysis is linear with the dose to about 13 Mrad after which it levels off as in p,p -ditolyI sulfone. However, the yield of S02 in this case is much lower (a factor of 25) than in the case of p,p -ditolyl sulfone (G = 0.002 compared to G = 0.05). This stability of the dibenzothiophene sulfone could be partially due to back reaction to reform the parent sulfone and partially due to more efficient energy delocalization. The expected biphenylene product was not detected due to limitations of the analytical method. Bowmer and O Donnell70 studied the volatile products in y-radiolysis of dialkyl, alkyl aryl and diaryl sulfones. Table 2 gives the radiolytic yields of S02 and of the hydrocarbon products of the alkyl or aryl radicals. The hydrocarbon products are those obtained either by H atom abstraction or by radical combination. The authors69 suggested the mechanism... [Pg.914]

Receptor models are widely used tools for apportioning concentrations of pollutants to different sources. They can be factor analytical methods (PMF, PCA, UNMIX, etc.) or chemical mass balance (CMB). On the one hand, these methods revealed to be very valuable to identify the main sources/categories of PM pollution (road traffic, secondary particles, fuel oil combustion, sea salt, etc.) but on the other hand they experienced difficulties in separating the contributions of collinear sources such as mineral dust (natural resuspension) and road dust (anthropogenic) or co-variant sources such as vehicle exhaust and road dust [34, 44, 45, 49, 55, 58, 110-113]). Significant improvements were made with the use of combination of models or constrained models such as the Multilinear Engine (ME-2). [Pg.178]

The analytical method deserves a detailed discussion for at least two major reasons. First, if used in conjunction with some constraint correction scheme," it is important in its own right as a practical method of solution of the constrained dynamics problem. Second, the method of undetermined parameters, central to the subject matter of this chapter, is an outgrowth of the analytical method hence a thorough understanding of the analytical method is an essential prerequisite for understanding the method of undetermined parameters. [Pg.81]

The (7), obtained by solving Eq. [39], are substituted into Eq. [37] to provide the displacements necessary to satisfy the constraints. Subsequently, the constrained position vectors r(tQ -I- 5f) are obtained from Eq. [38] by adding these constraint corrections to the partially constrained position vectors. The actual derivatives of order of the forces of constraint must be computed (a priori) in the analytical method, whereas in the method of undetermined parameters, the approximate derivatives of order of the forces of constraint can be computed (a posteriori) if desired, by replacing the X (fo)) by the (7). [Pg.99]

Chance et al. have also studied the EXAFS properties of the high-valent oxo-ferryl states of horseradish peroxidase, cytochrome c peroxidase, and myoglobin [144-146]. A two-atom-type constrained amplitude ratio fit and a three-atom-type consistency test were used for the analysis of the EXAFS data [144,146]. These analytical methods differ from that used by Hodgson and co-workers... [Pg.27]

Techniques have been developed within the CASSCF method to characterize the critical points on the excited-state PES. Analytic first and second derivatives mean that minima and saddle points can be located using traditional energy optimization procedures. More importantly, intersections can also be located using constrained minimization [42,43]. Of particular interest for the mechanism of a reaction is the minimum energy path (MEP), defined as the line followed by a classical particle with zero kinetic energy [44-46]. Such paths can be calculated using intrinsic reaction coordinate (IRC) techniques... [Pg.253]

Shih WC, Bechtel KL, Feld MS. Constrained regularization hybrid method for multivariate calibration. Analytical Chemistry 2007, 79, 234-239. [Pg.353]


See other pages where Analytical methods constrained is mentioned: [Pg.156]    [Pg.117]    [Pg.83]    [Pg.123]    [Pg.290]    [Pg.295]    [Pg.417]    [Pg.1]    [Pg.81]    [Pg.82]    [Pg.94]    [Pg.94]    [Pg.96]    [Pg.97]    [Pg.133]    [Pg.236]    [Pg.295]    [Pg.1652]    [Pg.543]    [Pg.950]    [Pg.289]    [Pg.164]    [Pg.35]    [Pg.354]    [Pg.353]    [Pg.22]    [Pg.68]    [Pg.283]    [Pg.20]    [Pg.20]    [Pg.85]    [Pg.43]    [Pg.408]    [Pg.408]    [Pg.23]    [Pg.340]    [Pg.296]    [Pg.50]    [Pg.493]    [Pg.28]   
See also in sourсe #XX -- [ Pg.267 ]




SEARCH



Constrained methods

© 2024 chempedia.info