Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analyte-sensitive hydrogels

The appUcability of a pH-sensitive hydrogel for sensors can be extended greatly by adding an intermediate step where an analyte is converted to pH, as for example, in the hydrogel-based Pco2 sensor where COj gas forms carbonic acid in water, resulting in a change in the pH and thus indirectly in the volume of the pH-sensitive HGs (Herber et /., 2005). [Pg.78]

Enzyme-sensitive supramolecular polymers also hold promise in analytical applications such as the screening of enzyme inhibitors. A simple visual assay based on the hydrogelation of small molecules has been developed for screening the activities of inhibitors of enzymes like acid phosphatase. A number of inhibitors for... [Pg.138]

In our previous study a novel method was developed to prepare a protein-based hydrogel, i.e., a Three-Dimensional Nanos-tructured Protein Hydrogel (3-D NPH), which is composed of protein-polymer hybrid nanoparticles (19, 20). The 3-D NPH could be easily prepared by dispensing a protein and polymer mixture on a substrate. Because the analyte proteins could penetrate into the 3-D NPH, the protein array made by 3-D NPH method has tremendously improved sensitivity in detecting protein-protein interactions compared with that of the direct protein immobilization methods (2-D). [Pg.216]

Ehnas had detailed a temperature-sensitive copolymer, which contained boronic acid units its interaction with ARS and loss of flnorescence upon exposure to a series of analytes was discnssed. " However, boronic acid containing hydrogels that had been developed for electrophoresis applications (discnssed later) were reasoned to be snit-able in the stationary phase for a similar supported system. Thus, this platform allows a dye displacement assay to be performed. " ... [Pg.1328]

The optical indicator dye need not be embedded into the silicone film itself. For instance, a usual way to monitor gases that are able to cross a siUcone thin membrcuie but require water to provide the analytical signal change, is to dissolve the indicator dye (typically a pH-sensitive one) in water or a hydrated hydrogel and separate this sensitive layer from the sample by means of the undoped silicone film. Typical... [Pg.349]


See other pages where Analyte-sensitive hydrogels is mentioned: [Pg.366]    [Pg.366]    [Pg.365]    [Pg.539]    [Pg.215]    [Pg.163]    [Pg.293]    [Pg.422]    [Pg.110]    [Pg.96]    [Pg.125]    [Pg.1310]    [Pg.107]    [Pg.192]    [Pg.215]    [Pg.80]    [Pg.389]    [Pg.1513]    [Pg.476]    [Pg.162]    [Pg.235]    [Pg.286]    [Pg.731]    [Pg.1208]    [Pg.431]    [Pg.386]    [Pg.455]    [Pg.456]    [Pg.4]   
See also in sourсe #XX -- [ Pg.366 ]




SEARCH



Hydrogels sensitivities

© 2024 chempedia.info