Sensitivity and absorption

The introduction of 2-[4-(dimethylamino)phenylazo]benzoic acid into a silica sol allows the preparation of pH-sensitive doped coatings upon glass substrates. The behavior of this system was evaluated as the function of pH changes in liquid and gas media68. Optical absorption and sensitivity against pH were monitored by Vis spectroscopy. Chemical and mechanical stability tests carried out with coatings demonstrated that they were resistant enough to be use in sensor devices for pH measurements in laboratories. [Pg.368]

The 2003 ACGIH threshold limit value-time-weighted average TLV-TWA is 2 ppm (7mg/m ) with a notation for skin absorption and sensitization. [Pg.451]

The most severe problems exist with peptide ligands, and this is particularly the case for the high-throughput screening of peptide libraries. Once an active peptide has been discovered, it will be necessary to design a suitable non-peptide analogue to avoid the problems of poor absorption and sensitivity to peptidases that confound the direct use of peptides as drugs. It will be necessary to know the conformation of the peptide lead. [Pg.86]

Table 1 The Effects of X Substituents of the Anilide Functionality on the Absorption and Sensitivity of a Series of Dual Layer Photoreceptors Using a Diaminofluorenone bisazo Pigment in the Generation Layer. (After Hashimoto, 1986)... Table 1 The Effects of X Substituents of the Anilide Functionality on the Absorption and Sensitivity of a Series of Dual Layer Photoreceptors Using a Diaminofluorenone bisazo Pigment in the Generation Layer. (After Hashimoto, 1986)...
Hydroxy terminated polybutadiene (PBU) [2] has also been used for special types of PUs elastomers where products of low water absorption and sensitivity are required. In general the mechanical strength of this class of PUs is lower than that of their polyester and polyether analogues with the advantage of giving PUs of very low glass transition temperatures and hence temperature flexibility. [Pg.12]

The major disadvantage of phenolics is low insulation resistance. Phenolics generally exhibit greater water absorption and sensitivity of the electrical properties to humid environments than epoxy resins, although only the so-called low-loss grades are used for printed wiring substrates. For these reasons, the use of phenolics in laminate fabrication has been restricted to the lower cost paper-based reinforcements. [Pg.304]

Note that in liquid phase chromatography there are no detectors that are both sensitive and universal, that is, which respond linearly to solute concentration regardless of its chemical nature. In fact, the refractometer detects all solutes but it is not very sensitive its response depends evidently on the difference in refractive indices between solvent and solute whereas absorption and UV fluorescence methods respond only to aromatics, an advantage in numerous applications. Unfortunately, their coefficient of response (in ultraviolet, absorptivity is the term used) is highly variable among individual components. [Pg.27]

The choice between X-ray fluorescence and the two other methods will be guided by the concentration levels and by the duration of the analytical procedure X-ray fluorescence is usually less sensitive than atomic absorption, but, at least for petroleum products, it requires less preparation after obtaining the calibration curve. Table 2.4 shows the detectable limits and accuracies of the three methods given above for the most commonly analyzed metals in petroleum products. For atomic absorption and plasma, the figures are given for analysis in an organic medium without mineralization. [Pg.38]

Sensitivity The sensitivity of a molecular absorption analysis is equivalent to the slope of a Beer s-law calibration curve and is determined by the product of the analyte s absorptivity and the pathlength of the sample cell. Sensitivity is improved by selecting a wavelength when absorbance is at a maximum or by increasing the pathlength. [Pg.411]

Spectral Sensitization. The intrinsic absorption, and therefore the intrinsic photographic sensitivity, of silver bromide and silver iodobromide microcrystals falls off rapidly for wavelengths greater than 500 nm (see Fig. 2). In fact, silver chloride crystals have almost no sensitivity in the visible... [Pg.448]

Aluminum is best detected quaUtatively by optical emission spectroscopy. SoHds can be vaporized direcdy in a d-c arc and solutions can be dried on a carbon electrode. Alternatively, aluminum can be detected by plasma emission spectroscopy using an inductively coupled argon plasma or a d-c plasma. Atomic absorption using an aluminum hoUow cathode lamp is also an unambiguous and sensitive quaUtative method for determining alurninum. [Pg.105]

Although the usual absorption and scattering spectroscopies caimot distinguish enantiomers, certain techniques are sensitive to optical activity in chiral molecules. These include optical rotatory dispersion (ORD), the rotation by the sample of the plane of linearly polari2ed light, used in simple polarimeters and circular dichroism (CD), the differential absorption of circularly polari2ed light. [Pg.319]

Bromo-2-pyridyla2o)-5-diethylamiQophenol (5-Br-PADAP) is a very sensitive reagent for certain metals and methods for cobalt have been developed (23). Nitroso-naphthol is an effective precipitant for cobalt(III) and is used in its gravimetric determination (24,25). Atomic absorption spectroscopy (26,27), x-ray fluorescence, polarography, and atomic emission spectroscopy are specific and sensitive methods for trace level cobalt analysis (see... [Pg.379]

Colorimetric procedures are often used to determine copper in trace amounts. Extraction of copper using diethyldithiocarbamate can be quite selective (60,62), but the method using dithhone is preferred because of its greater sensitivity and selectivity (50—52). Atomic absorption spectroscopy, atomic emission spectroscopy, x-ray fluorescence, and polargraphy are specific and sensitive methods for the deterrnination of trace level copper. [Pg.256]


See other pages where Sensitivity and absorption is mentioned: [Pg.190]    [Pg.578]    [Pg.619]    [Pg.235]    [Pg.239]    [Pg.14]    [Pg.41]    [Pg.368]    [Pg.502]    [Pg.738]    [Pg.368]    [Pg.190]    [Pg.578]    [Pg.619]    [Pg.235]    [Pg.239]    [Pg.14]    [Pg.41]    [Pg.368]    [Pg.502]    [Pg.738]    [Pg.368]    [Pg.1325]    [Pg.1793]    [Pg.2082]    [Pg.246]    [Pg.220]    [Pg.381]    [Pg.160]    [Pg.388]    [Pg.445]    [Pg.450]    [Pg.452]    [Pg.452]    [Pg.496]    [Pg.473]    [Pg.335]    [Pg.250]    [Pg.469]    [Pg.399]    [Pg.429]    [Pg.430]    [Pg.431]    [Pg.134]   