Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Weight restrictions

Conductive overlay systems are not practical propositions on vertical surfaces or surfaces where weight restrictions are important. However, they are proven cathodic protection systems, and should be considered in conjunction with other reinforced concrete cathodic protection system anodes. [Pg.189]

The advantages of conductive paints are that they are easy to apply and a concrete overlay is not required. They can be applied to complex shapes and are not a problem where weight restrictions are imposed. [Pg.191]

Fluid status - Prior to administration, assess the patient s volume (fluid) status carefully. It is imperative, especially prior to the first few doses, that there be no clinical evidence of volume overload or uncompensated heart failure, including a clear chest X-ray and weight restriction of less than or equal to 3% above the patient s minimum weight during the week prior to injection. [Pg.1978]

Clear chest X ray and weight restriction of <3% above patient s minimum weight during the week prior to injection... [Pg.15]

One of the problems in the mass spectrometric identification of unknown species is that of near-coincidence in mass between two different species. Thus CH4, NHj and O all have identical mass-numbers, and the number of overlapping species is inerted if any are isotopically substituted. Unequivocal identification requires the use of high resolution spectrometers capable of resolving to as much as one part in 10,000. On the other hand, if the reaction system is such that certmn species cannot be present, then lower resolution instruments may be suitable. In many cases a compromise must be reached. For example, mass spectrometers carried by rockets for investigations in the upper atniosphere must of necessity be light. Radio-frequency spectrometers of the kind described by Bennett satisfy the weight restriction, although the ultimate mass resolution is probably less than one in 100 with this kind of instrument. [Pg.295]

There is no single type of compressor that can be adapted to a particular application. The operating conditions, space, and weight restrictions must be reviewed before the appropriate compressor is selected. In addition, the type of driver requires selection because its selection and process conditions are interrelated. [Pg.420]

What significant hazards may exist (low bridges, weight restrictions, one-lane travel, etc.) ... [Pg.65]

Most states have adopted the federal HMTA and RCRA regulations, but some have additional restrictions. Most of the additional state restrictions pertain to routing restrictions, notification, public right-to-know laws, curfews, and size and weight restrictions. Five states have established specific routing requirements for RCRA hazardous wastes—Colorado, New Jersey, Idaho, Kansas, and Rhode Island. New Jersey is the only state that has requirements specific to the transport of CWM. [Pg.121]

Synthetic rebalancing cannot always be done, however. This is likely to be the case for rttiquid assets and those with legal covenants limiting transfer. For example, an investor may own a partnership or hold a concentrated stock position in a trust whose position cannot be swapped away. In these situations, MV optimization must be amended to include these assets with their weights restricted to the prescribed levels. The returns, risk, and correlation forecasts for the restricted assets must then be incorporated exphcitly in the analysis to take account of their interaction with other assets. The resulting constrained optimum portfolios will comprise a second-best efficient frontier but may not be too far off the unconstrained version. [Pg.763]

Are there state laws re truck size and weight restrictions Is site near a trucking gateway in order to reduce in-transit times ... [Pg.1482]

MS, however, offers a series of obvious advantages over NMR spectroscopy. They include superior resolution (if high-resolution MS detectors are employed), superior sensitivity, more facile and economical coupling to online separation techniques (LC and GC), analysis of samples in aU three states of matter (gas, liquid, and solid), no molecular weight restrictions, and finally the ability to trap selected ions in the gas phase prior to characterization, thereby allowing a second dimension of separation. For complex samples containing natural products as minor constituents, especially, structure elucidation by MS constitutes the only practical access to natural product structures. [Pg.307]

Solid-phase synthesis is a more promising method, that offers high efficiencies, nonchromatographic purifications, and an accelerated oligomer growth process. However, the method suffers from severe limitations in the analysis of resin-bound products and intermediates, in product molecular weight restrictions, and also structural defects in sequences due to incomplete reactions. [Pg.259]

Eurocode road traffic load models for weight restricted bridges... [Pg.1334]

This gradation cannot be found either in the Eurocode or in the German DIN-report 101. Ifthe codes ofprac-tice no longer offer special load patterns for weight restricted historical bridges, it would be helpful to develop different characteristic road traffic loads for them. This is because historical bridges still contribute... [Pg.1335]

Based on the limitation of the current Eurocode or DIN-report (i.e. neglecting models for weight restricted bridges), an extension of the Eurocode road traffic model should be introduced. However, the general procedure outlined in the Eurocode for the development of traffic models should continue to be used. The goal of the following presented research is the development of a -factors which can be applied to the... [Pg.1337]

The factors to be developed should deliver traffic models, which are comparable to the re-calibration classes of the DIN 1072. The number inside the class of the DIN 1072 gave the weight restriction for the lane, such as bridge class 30/30, 16/16 and 12/12. [Pg.1338]

Report suggests wider lanes, advance stop lines, cycle bypasses, speed controls and area and weight restrictions would all help to cut casualties. [Pg.93]

HPMA copolymer-doxorubicin has been widely evaluated in preclinical and clinical studies. It demonstrates marked advantages over free doxombidn control of biodistribution and accumulation via molecular weight restrictions [10,16,35,37,45], biodegradability [16-19,24,25,39,42], minimal immunogenicity [17-19, 25,38-44], subcellular localization [15-20], anticancer activity [33-36,43-46,54,55,57], enhanced permeability and retention [9,14,57,58], increased apoptosis [36], lipid peroxidation [57], DNA damage [57], and reduced nonspecific toxicity [14,33-35,43-46]. Recent cKnical trials in the UK provide proof of principle of the enhanced permeability and retention effect for solid tumors and the unique advantages of this novel drug delivery system for the treatment of ovarian cancer. [35,43-46]... [Pg.117]

With regards to photodynamic therapy using the photosensitizer mesochlorin Ce, the precKnical evaluations thus far document control of biodistribution and accumulation via molecular weight restrictions [10,11,16,33], biodegradability [14,43], subcellular locaKzation [15-19], anticancer activity [33,55,56], enhanced permeability and retention [55], and reduced nonspecific toxicity [33],... [Pg.117]

The units typically range from 5000 to 100,000 scfm and wei several tons. The size and weight restrict the location of the incinerator. The recuperative incinerator should be considered when airflow rates are several thousand scfm. [Pg.280]

Figure 3 Illustration of the restriction and interpolation operations. Full weighting restriction (left) averages the three fine-grid values to yield the coarse-grid value. Interpolation injects the values from the coarse grid, which are included in the fine grid, and averages two coarse values to generate the intermediate fine-grid value. Figure 3 Illustration of the restriction and interpolation operations. Full weighting restriction (left) averages the three fine-grid values to yield the coarse-grid value. Interpolation injects the values from the coarse grid, which are included in the fine grid, and averages two coarse values to generate the intermediate fine-grid value.

See other pages where Weight restrictions is mentioned: [Pg.720]    [Pg.540]    [Pg.76]    [Pg.48]    [Pg.142]    [Pg.138]    [Pg.351]    [Pg.532]    [Pg.1489]    [Pg.555]    [Pg.56]    [Pg.366]    [Pg.16]    [Pg.32]    [Pg.336]    [Pg.1334]    [Pg.1338]    [Pg.1339]    [Pg.3027]    [Pg.633]    [Pg.645]    [Pg.321]    [Pg.605]    [Pg.388]    [Pg.89]   


SEARCH



© 2024 chempedia.info