Wavelength Measurements

Optical Properties and Radiation Effects. Within the range of wavelengths measured (uv, visible, and near-ir radiation), Teflon PFA fluorocarbon film transmits slightly less energy than FEP film (29) (Table 6). In thin sections, the resin is colorless and transparent in thicker sections, it becomes translucent. It is highly transparent to it radiation uv absorption is low in thin sections. Weather-O-Meter tests indicate unlimited outdoor life. [Pg.376]

The first and second Planck-law constants c and C9 are respectively (3.740)(10- ) (Jm )/s and (1.4388)(10- ) m K. The term clearly a function only of the product XT, is given in Fig. 5-11 which may be visualized as the monochromatic emissive power versus wavelength measured in vacuo of a black surface at 1 K discharging in vacuo. [Pg.570]

The three normal means of presenting the spectrophotometric data are described below by far the most common procedure is to plot absorbance against wavelength (measured in nanometres). The wavelength corresponding to the absorbance maximum (or minimum transmission) is read from the plot and is used for the preparation of the calibration curve. This point is chosen... [Pg.708]

Detect 100% of photons Photon detected as a delta function Large number of pixels Time tag for each photon Measure photon wavelength Measure photon polarization No detector noise fr Up to 99% detected fr One electron for each photon fr Over 377 million pixels 0 No - framing detectors 0 No - provided by optics 0 No - provided by optics 0 Readout noise and dark current... [Pg.127]

Fig. 4. PL spectra as a function of emission peak energy (i.e., wavelength) measured at room temperature. Fig. 4. PL spectra as a function of emission peak energy (i.e., wavelength) measured at room temperature.
The absorbance of the PPV LB film at peak wavelength measured with polarized light parallel to the dipping direction is about twice large that measured with polarized light perpendicular to the dipping direction. The anisotropy of absorbance... [Pg.325]

FIGURE 6.28 The ambient light reflection as a function of the wavelength measured for a control device and structurally identical OLEDs made with two different bilayer ITO anodes. [Pg.520]

N. Okui and E. Okada. Wavelength dependence of crosstalk in dual-wavelength measurement of oxy- and deoxy-hemoglobin. Journal of Biomedical Optics, 10(l) 011015-l-011015-8, 2005. [Pg.370]

Among optical sensors, those based on fluorescence are of major interest because of their ability to use spectral and temporal information multi-wavelength measurements allow simultaneous detection of two or more analytes, and discrimination between analytes is possible by time-resolved measurements. Multiplex capabilities represent the main advantage of such sensors compared to electrochemical devices. [Pg.334]

Appendix A. Spectrophotometric and spectrofluorometric pH titrations Single-wavelength measurements... [Pg.337]

From precise wavelength measurements of the fluorescence spectrum (which may be performed e. g. by interferometric methods accurate values for the molecular constants can be obtained since the wavelength differences of subsequent lines in the fluorescence progression yield the energy separation of adjacent vibrational and rotational levels as a function of v . From these spectroscopically deduced molecular constants, the internuclear distance can be calculated A special computer programm developed by Zare ) allows the potential curve to be constructed from the measured constants and, if the observed fluorescence progression... [Pg.20]

Several investigations concerned with the identification of these lines succeeded, for instance, in the case of H2O, in elucidating the rotational spectrum in excited vibrational states 356). Through comparison of wavelengths and intensities of many lines in H2O , H2 0 and DjO isotopic effects could be studied in these excited vibrational levels 357,358) Perturbations of rotational levels by Coriolis resonance which mixes different levels could be cleared up through the assignment and wavelength measurement of some DCN and HCN laser lines 359). [Pg.73]

To begin with, we must specify the spectral window we are referring to and then use the appropriate detector telescope, radiotelescope or space-borne observatory. The next characteristic is the accuracy of the energy, frequency or wavelength measurement, followed by the accuracy of the angular measurement (resolving power), and the temporal resolution and sensitivity of the measurement. Finally, we note the direction, date and duration of the observation for each particular celestial object we choose to investigate. [Pg.27]

In Ref. 77, the (direct) bandgap of 1.8 eV was compared to the bulk value of ca. 1.3 eV bulk and the difference ascribed to size quantization. The absorption spectrum shows considerable absorption to beyond 820 nm (the maximum wavelength measured), and it is not clear whether this is due to scattering or to a lower-energy (possibly indirect) absorption. [Pg.378]

Sample ICP-MS Laser system/ Wavelength Measured isotope ratio RSD (%) Application Reference... [Pg.236]

To begin with, it is worth talking about typical data structures used for chemo-metric analysis of NIR spectra. Typically, the unprocessed spectral data are put in a design matrix where each column contains the absorbance at a given wavelength (the number of columns equals the number of wavelengths measured) and each row contains the spectrum of an individual sample (the number of rows equals the number of samples). [Pg.405]

The characteristic orange light produced by sodium in a flame is due to an intense emission called the sodium D line. This line" is actually a doublet, with wavelengths (measured in vacuum) of 589.157 88 and 589.755 37 nm. The index of refraction of air at a... [Pg.399]

The index of refraction of air varies with temperature and pressure standard air is defined as dry air at 15°C and 1 atmosphere pressure, with 0.03 percent C02. To correct wavelengths measured in air to vacuum, we add (n — l)Aair. Some values of n — 1 for standard air are6... [Pg.71]

A certain spectral line of cadmium often is used as a standard in wavelength measurements. The wavelength is 0.000064384696 cm. Express this wavelength (a) in angstroms, and (b) in nanometers. [Pg.40]

Less expensive instruments give a direct readout of absorbance and/or transmittance in analog or digital form. These instruments are suitable for single-wavelength measurements however, if a scan of absorbance vs. wavelength (Figure 5.4) is desired, some type of device to display the spectrum must be available. [Pg.149]


See other pages where Wavelength Measurements is mentioned: [Pg.14]    [Pg.20]    [Pg.436]    [Pg.570]    [Pg.76]    [Pg.1310]    [Pg.173]    [Pg.34]    [Pg.408]    [Pg.369]    [Pg.313]    [Pg.365]    [Pg.464]    [Pg.142]    [Pg.403]    [Pg.267]    [Pg.214]    [Pg.338]    [Pg.341]    [Pg.344]    [Pg.294]    [Pg.72]    [Pg.73]    [Pg.202]    [Pg.18]    [Pg.34]    [Pg.214]    [Pg.343]    [Pg.435]    [Pg.175]   
See also in sourсe #XX -- [ Pg.166 ]

See also in sourсe #XX -- [ Pg.192 ]

See also in sourсe #XX -- [ Pg.174 ]

See also in sourсe #XX -- [ Pg.168 ]




SEARCH



Absolute wavelength measurements

Absorbance, measurement wavelength

Absorption measurements excitation wavelength

Accurate Wavelength Measurements

Color measurements wavelength

Dual-wavelength measurements

Identification by Wavelength Measurement

Measurement wavelength, choice

Measurement wavelength, optimal

New Techniques of Wavelength Measurements

Peak wavelength, spectrophotometric measurements

Precision and Accuracy of Wavelength Measurements

Quantitative Measurements at Fixed Wavelength

Wavelength and Frequency Measurements

Wavelength calibration measurements

Wavelength, light, measurement

Wavelength, light, measurement accuracy

Wavelength, light, measurement technique