Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Wavelength dispersive X-rays

A widely used procedure for determining trace amounts of selenium involves separating selenium from solution by reduction to elemental selenium using tellurium (as a carrier) and hypophosphorous acid as reductant. The precipitated selenium, together with the carrier, are collected by filtration and the filtered soflds examined directly in the wavelength-dispersive x-ray fluorescence spectrometer (70). Numerous spectrophotometric and other methods have been pubHshed for the deterruination of trace amounts of selenium (71—88). [Pg.335]

Wavelength dispersive x-ray fluorescence spectrometric (xrf) methods using the titanium line at 0.2570 nm may be employed for the determination of significant levels of titanium only by carefiil matrix-matching. However, xrf methods can also be used for semiquantitative determination of titanium in a variety of products, eg, plastics. Xrf is also widely used for the determination of minor components, such as those present in the surface coating, in titanium dioxide pigments. [Pg.134]

An energy-dispersive X-ray spectrometer and at least one wavelength-dispersive X-ray spectrometer... [Pg.175]

The electron-optical performance of the EPMA system is indistinguishable from that of a conventional scanning electron microscope (SEM) thus, EPMA combines all of the imaging capabilities of a SEM with quantitative elemental analysis using both energy- and wavelength-dispersive X-ray spectrometry. ... [Pg.176]

Wavelength Dispersive (X-Ray) Spectroscopy Wavelength Dispersive X-Ray Spectroscopy... [Pg.769]

Before the development of semiconductor detectors opened the field of energy-dispersive X-ray spectroscopy in the late nineteen-sixties crystal-spectrometer arrangements were widely used to measure the intensity of emitted X-rays as a function of their wavelength. Such wavelength-dispersive X-ray spectrometers (WDXS) use the reflections of X-rays from a known crystal, which can be described by Bragg s law (see also Sect. 4.3.1.3)... [Pg.197]

FCC feedstocks contain sulfur in the form of organic-sulfur compounds such as mercaptan, sulfide, and thiophenes. Frequently, as the residue content of crude oil increases, so does the sulfur content (Table 2-5). Total sulfur in FCC feed is determined by the wavelength dispersive x-ray fluorescence spectrometry method (ASTM D-2622), The results are expressed as elemental sulfur. [Pg.58]

Examples of using reference samples for calibration can be found in several chapters of the uses Methods for Geochemical Analysis (Baedecker 1987). Solid reference sample powders are used in cahbrating the dc arc emission, energy-dispersive X-ray and instrumental neutron activation analyses described, while acid-dissolved rock reference samples are used for IGP emission analyses and fused reference samples are used for wavelength-dispersive X-ray analyses. [Pg.224]

Taggart JE Jr, Lindsay JR, Scott BA, Vivit DV, Bartel AJ, Stewart K C (1993) Analysis of geological materials by wavelength-dispersive X-ray fluorescence spectrometry. In Badecker PA, ed. U.S. Geological Survey Bulletin 1770. Methods for Geochemical Analysis, pp E1-E19. [Pg.234]

Table 8.38 Main features of wavelength-dispersive X-ray fluorescence spectrometry (WDXRF)... Table 8.38 Main features of wavelength-dispersive X-ray fluorescence spectrometry (WDXRF)...
Falcone, R., A. Renier, and M. Verita, M. (2002), Wavelength-dispersive X-ray fluorescence analysis of ancient glasses, Archaeometry 44(4), 531-542. [Pg.573]

Elemental analysis can also be performed on SEM samples using x-ray spectrometer attachments [55], The techniques are known as energy dispersive x-ray (EDX) analysis and wavelength dispersive x-ray (WDX) analysis and require installation of a detector in the sample chamber. [Pg.147]

Wavelength dispersive X-ray fluorescence spectrometric (xrf) methods, 25 60 Wavelength dispersive spectrometer (WDS), 76 488, 26 433-434 Wavelength dispersive X-ray fluorescence (WDXRF)... [Pg.1016]

This non-destructive technique is a very suitable tool for rapid in-line analysis of inorganic additives in food products (Price and Major, 1990 Anon, 1995). It can be readily used by non-skilled operators, and dry materials can be pressed into a pellet or simply poured into a sample cup. The principles of this technique related to food analysis are described by Pomeranz and Meloan (1994). A useful Internet site is http //www.xraysite.com, which includes information about different XRF instruments from various companies. Wavelength dispersive X-ray fluorescence (WD-XRF) or bench-top energy dispersive (ED-XRF) instruments are available. XRF is a comparative technique, thus a calibration curve needs to be established using food products of the same type as those to be... [Pg.129]

The wavelength-dispersive x-ray spectroscopy method (ASTM D6376) provides a rapid means of measuring metallic elements in coke and provides a guide for determining conformance to material specifications. A benefit of this method is that the sulfur content can also be used to evaluate potential formation of sulfur oxides, a source of atmospheric pollution. This test method specifically determines sodium, aluminum, silicon, sulfur, calcium, titanium, vanadium, manganese, iron, and nickel. [Pg.301]

TGA/DTA combined thermogravimetry / differential thermal analysis WDX wavelength-dispersive X-ray diffraction... [Pg.102]

Part VI Wavelength Dispersive X-ray Spectrometers , Anal. Proc.,... [Pg.79]


See other pages where Wavelength dispersive X-rays is mentioned: [Pg.324]    [Pg.285]    [Pg.58]    [Pg.75]    [Pg.194]    [Pg.761]    [Pg.28]    [Pg.302]    [Pg.196]    [Pg.213]    [Pg.1016]    [Pg.46]    [Pg.48]    [Pg.104]    [Pg.111]    [Pg.256]    [Pg.60]    [Pg.115]    [Pg.165]    [Pg.100]    [Pg.285]   


SEARCH



Energy and wavelength dispersive x-ray

WDX (Wavelength dispersive x-ray

Wavelength X-ray

Wavelength dispersion

Wavelength dispersive X-ray fluorescence WDXRF)

Wavelength dispersive X-ray spectrometry

Wavelength dispersive x-ray analysis

Wavelength dispersive x-ray spectrometer (WDS

Wavelength-dispersive

Wavelength-dispersive X-ray analysi

Wavelength-dispersive X-ray fluorescence

Wavelength-dispersive X-ray spectroscopy

Wavelength-dispersive x-ray spectrometer

X dispersive

X-ray dispersion

X-ray microanalysis wavelength dispersive

© 2024 chempedia.info