Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tuned liquid column damper

Balendra T, Wang C. M., Cheon N. F., (1995). Effectiveness of tuned liquid column dampers for vibration control of towers. Engineering Structures 17(9), 668-675. [Pg.245]

Hochrainer, M. J. (2005). Tuned liquid column damper for structural control. Acta Mechanica, 175(1-4), 57-76. doi 10.1007/s00707-004-0193-z... [Pg.176]

Hochrainer, M. J., Ziegler, F. (2006). Control of tall building vibrations by sealed tuned liquid column dampers. Structural Control and Health Monitoring, 13(6), 980-1002. doi 10.1002/stc.90... [Pg.177]

Reiterer, M., Ziegler, F. (2004). Bi-axial seismic activation of civil engineering structures equipped with tuned liquid column dampers. Journal of Seismology and Earthquake Engineering, 6(3), 45-60. [Pg.177]

Gao, H., Kwok, K. S. C., Samali, B. (1999). Characteristics of multiple tuned liquid column dampers in suppressing structural vibration. Engineering Structures, 21, 316-331. doi 10.1016/ S0141-0296(97)00183-l... [Pg.178]

Sakai, F., Takaeda, S., Tamaki, T. (1989). Tuned liquid column dampers - New type device for suppression of building vibrations. Proceedings of the International Conference on High-rise Buildings, Nanjing, (pp. 926-931). [Pg.178]

Yalla, S. K., Kareem, A., Kantor, J. C. (2001). Semi-active tuned liquid column dampers for vibration control of structures. Engineering Structures, 23, 1469-1479. doi 10.1016/SO141-0296(01)00047-5... [Pg.178]

Actively and Semi-actively Controlled Structures Under Seismic Actions Modeling and Analysis, Fig. 7 Friction semi-active device (a) and semi-active tuned liquid column damper (b)... [Pg.4]

TLDs (Tuned Liquid Damper systems) dissipate energy using a secondary mass in the form of a body of liquid introduced into the structural system and tuned in such a way to act as a dynamic vibration absorber. TLDs are particularly effective for the suppression of lateral vibrations (e.g., due to wind or pedestrial loads) and were used for vibration control of the Toda Park Bridge in Japan. Similar devices to TLDs are TSDs (Tuned Sloshing Dampers) and TLCDs (Tuned Liquid Column Dampers). [Pg.542]

Hybrid TLCD (Tuned Liquid Column Dampers)... [Pg.547]

Di Matteo A, Lo lacono F, Navarra G, Pirrotta A (2014) Direct evaluation of the equivalent linear damping for tuned liquid column damper systems in random vibration for pre-design purpose. Int J Non-Linear Mech 63 19-30... [Pg.3813]

Tuned Liquid Column Gas Damper in Structural Control ... [Pg.150]

THE VERTICALLY ACTING TUNED LIQUID COLUMN GAS DAMPER... [Pg.172]

Fu, C., Ziegler, F. (2010). Vibration prone multi-purpose buildings and towers effectively damped by tuned liquid column-gas dampers. Asian Journal of Civil Engineering, 10 ), 21-56. [Pg.176]

Ziegler, F. (2008). Special design of tuned liquid column-gas dampers for the control of spatial structural vibrations. Acta Mechanica, 201, 249-267. doi 10.1007/S00707-008-0062-2... [Pg.177]

Ziegler, F., Khalid, B. (2011). A novel base isolation system for as5mimetric buildings in seismic active zones damping supplied by tuned liquid column-gas dampers. In Belyaev, A. K., Irschik, H., Krommer, M. (Eds.), Advanced dynamics and model based control of structures and machines (pp. 225-234). Wien, Austria Springer-Verlag. doi 10.1007/978-3-7091-0797-3 26... [Pg.177]


See other pages where Tuned liquid column damper is mentioned: [Pg.150]    [Pg.151]    [Pg.151]    [Pg.178]    [Pg.334]    [Pg.3575]    [Pg.150]    [Pg.151]    [Pg.151]    [Pg.178]    [Pg.334]    [Pg.3575]    [Pg.175]    [Pg.410]    [Pg.413]    [Pg.5]   
See also in sourсe #XX -- [ Pg.150 ]




SEARCH



Liquid column

Tuned liquid damper

Tuning

© 2024 chempedia.info