Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Trauzl lead block test

Methylnitramine explodes on heating or on contact with coned sulfuric acid. Based on tests conducted in the USA during WWII, it is more powerful than TNT (144% as detd by Trauzl lead block test) (Ref 3) ... [Pg.128]

Power. About 135% of TNT in BalMort Test about 160% of TNT in Trauzl Lead Block Test Rifle Bullet Test. High order detonations Thermal Stability. 9 to 30 minutes in 82.2°... [Pg.133]

Taylor (1952), Measurement of Detonation by Dautriche (pp 24-28) and by Rapid-Photography Methods (28-32) Heat of Explosion by Calorimetric Bomb (40-2) Temperature of Explosion (43-7) Power or Strength of High Explosives by Trauzl Lead Block Test, Ballistic Mortar Test and pendulum Test (185-86)... [Pg.314]

R.L. Grant J.E. Tiffany, Detonators Initiating Efficiency by the Miniature-Cartridge Test , USBurMinesTechPaper 677, GovtPtgOff, Washington, DC (1945) (Description of the test and its comparison with Lead-Plate Test, Small Trauzl Lead Block Test, Sand Test, Esop s Test, Desensitized Dynamite Test and TNT-Iron Oxide Insensitive Powder Test)... [Pg.1104]

Card gap sensitivity 6.25cm brisance 82 (TNT = 100) Trauzl lead block test 120.4 ... [Pg.197]

W() Kirk Othmer, Vol 8(1952), pp 654-57 (Section on Testing Exolosives which includes Impact Tests, Explosion Temperature Tests, Sensitivity to Initiation, Pendulum Friction Test, Rifle Bullet Test, Sand Test, Rate of Detonation Determination, Ballistic Pendulum Test, Trauzl Lead Block Test,... [Pg.347]

KL) Anon, "Military Explosives", TM 9-1300-214/TO 11A-1-34 (1967). Chapter 5. Properties and Tests of High Explosives Sensitivity to Frictional Impact (pp 5 1 to 5-3) Sensitivity to Friction (5 3 to 5-6) Sensitivity to Frictional Impact (5-6) Sensitivity to Heat and Spark, which includes Explosion Temperature Test (5-6 to 5-9) Sensitivity to Initiation (5-9) Stability Tests, which include 75° International Test, 100° Heat Test, Vacuum Stability Test and Potassium Iodide—Starch Test (5 9 to 5-15) Brisance Tests which include Sand Test, Plate Dent Test and Fragmentation Test (5 15 to 5-18 and Fig 5 13 on p 5-19) Initiating Value (5-18 5-20) Sympathetic Detonation (5-20 to 5-21) Power which includes Heat of Explosion Test, Ballistic Pendulum Test and Trauzl Lead Block Test (5-21. to 5-24) Blast Effect (5-24 to 5-27) Cratering Effect (5-28 5 29) and Munroe-Neumann Effect (5-29 to 5 35)... [Pg.353]

Impact Sensitivity by Brucetofl No 3 Apparatus, 50% positive in brass cups with 5kg weight at 90cm drop, vs 50cm for RDX Power by Ballistic. Mortar Test, 127% TNT Power by Trauzl Lead Block Test, 129% TNT Rate of Detonation. See Detonation Velocity Rifle Bullet Test. In 7 trials conducted in Canada with charges placed in steel pipe nipples — 5 passed, 1 detonated and 1 partially detonated... [Pg.423]

Coefficient d utilisation pratique, abbr as CUP or cup (Coefficient of Practical Utilization) or Epreuve de travail specifique (Specific Work Test). It is Dautriche s modification of Trauzl Lead Block Test. See Ref 20, pp IX X Ref 4, p 472 Ref 8, p 171 Ref 10, p 66... [Pg.578]

Trauzl Lead Block Test, See under Power (or Strength)... [Pg.604]

Figure 3.21 Trauzl/lead block test. Reprinted from Meyer, R. Explosives, 1987 1987, Wiley-VCH Verlag GmbH, Weinheim, Germany. Figure 3.21 Trauzl/lead block test. Reprinted from Meyer, R. Explosives, 1987 1987, Wiley-VCH Verlag GmbH, Weinheim, Germany.
ATX is a powerful expl very sensitive to impact. It was claimed in Germany to be more powerful than RDX as judged by Trauzl Lead Block Test (Ref 2)... [Pg.189]

Note Trauzl Lead Block Test, such as described in Vol 1 (Ref 9, ppXXV XXVI) is used in foreign countries (See also Ref 14, p 5-23)... [Pg.513]

Allylpicrate is an expl about 85% as powerful as TNT as judged by the TrauzL lead block test (Ref 4)... [Pg.139]

In the Trauzl lead block test (often called simply the lead block test) 10 grams of the explosive, wrapped in tinfoil and stemmed with sand, is exploded by means of an electric detonator in a cylindrical hole in the middle of a cylindrical block of lead, and the enlargement of the cavity, measured by pouring in water from a graduate and corrected for the enlargement which is ascribable to the detonator alone, is reported. For the standard test, the blocks are cast from chemically pure lead, 200 mm. in height and 200 mm. in diameter, with a central hole made by the mold, 125 mm. deep and 25 mm. in diameter The test is... [Pg.24]

Naoum 25 reports the results of his own experiments with nitroglycerin and with other explosives in the Trauzl lead block test (sand tamping), 10-gram samples, as shown below. The Trauzl test is essentially a measure of brisance, but for explosives of similar... [Pg.210]

Propylene glycol dinitrate is a colorless liquid of characteristic aromatic odor, more volatile and less viscous than trimethylene glycol dinitrate with which it is isomeric. Its specific gravity (20°/4°) is 1.368 at 20°. It boils at 92° at 10 mm., and does not freeze at —20°. Its solubilities, gelatinizing power, and explosive properties are substantially the same as those of its isomer. Indeed, Naoum 60 reports that it gave exactly the same expansion as trimethylene glycol dinitrate in the Trauzl lead block test, namely, 540 cc. [Pg.234]

Fig. 6.15 Trauzl (lead block) test 1 sand stemming, 2 test sample, 3 lead block, V original volume of the cavity (61 cm3). Fig. 6.15 Trauzl (lead block) test 1 sand stemming, 2 test sample, 3 lead block, V original volume of the cavity (61 cm3).
Test — 114% TNT. Trauzl Lead Block Test — 115% PA or 120-125% TNT Rifle Bullet Test was detd by Me dard Cessat (Ref 7a) for charges of sp gr 1.0 — no detonations on impact of bullets with velocities below 960m/sec and incomplete detons for velocities around lOOOm/sec... [Pg.109]

In the Trauzl lead block test (often called simply the lead ... [Pg.339]


See other pages where Trauzl lead block test is mentioned: [Pg.309]    [Pg.317]    [Pg.601]    [Pg.307]    [Pg.422]    [Pg.61]    [Pg.722]    [Pg.368]    [Pg.61]    [Pg.325]    [Pg.255]    [Pg.207]    [Pg.307]    [Pg.422]    [Pg.61]    [Pg.601]    [Pg.73]    [Pg.61]   
See also in sourсe #XX -- [ Pg.73 ]




SEARCH



Block tests

Lead block test

Lead blocks

Trauzl test

© 2024 chempedia.info