Transmission network

EERC beheves that 137 utihties wih be required to open up their transmission networks. As of mid-1996, the NOPR is stih being debated. However, several states have adopted preliminary plans to open up the transmission networks of their regulated utihties by the year 2000 or shortiy thereafter. [Pg.89]

In a large power station, connected to a transmission network through a power grid, system disturbances are a common feature. Foi details see Section 17.5. [Pg.186]

To increase the impedance of the network, a series resistor or reactor is sometimes used to contain the fault level of a system within a desirable limit. This may be required to make the selection of the interrupting device easy, and from the available range, without an extra cost for a new design as well as an economical selection of the interconnecting conductors and cables. Such a situation may arise on HV >66 kV or EFIV > 132. kV transmission networks, when they are being fed by two or more power sources, which may raise the fault level of the system to an unacceptable level. The cost of the interrupting device for such a fault level may become disproportionately high, and sometimes even pose a problem in availability. [Pg.346]

Overcurrent protection is normally not provided in generator and generator transformers to save the machines from likely outages on momentary overlo.ids. In the event of overloading, the normal practice is to shed some of the loads on the transmission network. [Pg.511]

Since a switchyard is normally connected to more than one supply system, the ground fault current in a power station is contributed by the power plant as well as by the switchyard and the transmission networks. The following possibilities may arise ... [Pg.706]

Figure 24,1 A simple transmission network with series compensation... Figure 24,1 A simple transmission network with series compensation...
To neutralize atid reduce substantially the content of inductive reactance of the line. Refer to a simple transmission network with series compensation, show n in Figure 24.1,... [Pg.779]

One example of the complexity of the process was in load forecasting technology. By the 1960s and 1970s, utilities had developed processes to replicate the extensive electric power system for study purposes to include generation resources, transmission networks and individual points of load seiwice to customers. The... [Pg.1199]

With the opening of the transmission network to all resource suppliers, many marketing entities entered the game in the mid-1990s. Many of these marketers are subsidiaries of already established gas suppliers. Some have been created solely for the electric industry. Still others have been formed from the utilities themselves. All of these etitities arc competition-motivated. Facility planning and reliability issues, while important to their business, are left to other organizations. [Pg.1202]

The planning and construction of generation and transmission facilities by utilities came to a virtual halt. With no guaranteed market, no control over the use of their transmission networks, no assurance of stranded investment recovery, and no assurance of federal remedial treatment, the economic structure of utility planning and construction of generation facilities basically stopped in place. [Pg.1202]

Nonlinear programming Staged-Distillation column (12.1) < Liquid extraction column (12.2) Gas transmission network (13.4) Ammonia reactor (14.2) Alkylation reactor (14.3) CVD reactor (14.5) Refrigeration process (15.2) Extractive distillation (15.3) Operating margin (15.4) Reactor control (16.3)... [Pg.416]

After selection of the partition variable, the next step is to determine how the variable should be partitioned. It was decided to check each compressor in the branch of the transmission line associated with the partition variable, and if any compressor operated at less than 10 percent of capacity, it was assumed the compressor was not necessary in the line. (If all operate at greater than 10 percent capacity, the compressor with the smallest compression ratio was deleted.) For example, with N2 selected as the partition variable, and one of the three possible compressors in branch 2 of the gas transmission network operating at less than 10 percent of capacity, the first partition would lead to the tree shown in Figure E13.4c N2 would either be 3 or would be 0 < A2 < 2. Thus at each node in the tree, the upper or lower bound on the number of compressors in each branch of the pipeline is readjusted to be tighter. [Pg.475]

Figure E13.4d compares the optimal gas transmission network with the original network. From a nonfeasible starting configuration with 10-mile-long pipeline segments, the nonlinear optimization algorithm reduced the objective function from the first feasible state of 1.399 X 107 dollars/year to 7.289 X 106 dollars/year, a savings of close to 7 million. Of the ten possible compressor stations, only four remained in the final optimal network. Table E13.4a lists the final state of the network. Note that because the suction and discharge pressures for the pipeline segments in branch 2 are identical, compressors 4, 5, 6, and 7 do not exist in the optimal configuration, nor do 9 and 10 in branch 3. Figure E13.4d compares the optimal gas transmission network with the original network. From a nonfeasible starting configuration with 10-mile-long pipeline segments, the nonlinear optimization algorithm reduced the objective function from the first feasible state of 1.399 X 107 dollars/year to 7.289 X 106 dollars/year, a savings of close to 7 million. Of the ten possible compressor stations, only four remained in the final optimal network. Table E13.4a lists the final state of the network. Note that because the suction and discharge pressures for the pipeline segments in branch 2 are identical, compressors 4, 5, 6, and 7 do not exist in the optimal configuration, nor do 9 and 10 in branch 3.
Direct current from the power section is collected on a bus bar and connected to the power conditioning subsystem. Here, the dc power is converted to. 1-pha.se, 50 Hz alternating current that is fed inlo the utility s 66 kV transmission network. [Pg.690]

Researchers (AT T Bell Laboratories) have demonstrated that erbium-doped devices (Fig. 12) can boost signals traveling at any bit rate, transmission networks can be upgraded by simply changing the transmitters (and receivers). Virtually any video data or voice signal can be dumpled like marbles into one end of the transparent light pipes and roll out intact at the other end/ ... [Pg.1158]

Naturally, this strategy must be compatible with the multiple operating constraints of the facilities (minimum and maximum volumes, minimum and maximum reservoir pressures, minimum and maximum stored volumes, gas treatment and compression facilities saturation, etc.), of the transmission network (transportation situation) and of the supply contracts (contracted volumes and rates). [Pg.189]

The wheeling of power from wind turbines to electrolizers on strong transmission networks. [Pg.69]

Autonomous power systems (APS) comprise a solution for the electrification of applications when the access to a large transmission network is not economically viable or even impossible. Their size can range from few hundred Watts to tens or hundreds of MW. [Pg.6]

Fincham, A.E. and Goldwater, M.H. (1979). Simulation models for gas transmission networks, Trans. Inst. Measurement and Control, 1, 3-12. [Pg.31]

The type of feeder cables described in this section are those between switchboards within an oil industry site, rather than those between a utility power plant and an oil industry site. These feeders may be described as primary feeders as opposed to secondary feeders downstream in the system. Feeders from a utility power plant or a transmission network have protective relaying systems that are more sophisticated than those described herein, e.g. multi-zone distance protection, admittance relays, carrier protection schemes. [Pg.332]

Synchronous Generator - An electrical generator that runs at a constant speed and draws its excitation from a power source external or independent of the ioad or transmission network it is supplying. [Pg.421]


See other pages where Transmission network is mentioned: [Pg.128]    [Pg.426]    [Pg.426]    [Pg.1104]    [Pg.1200]    [Pg.1202]    [Pg.460]    [Pg.469]    [Pg.660]    [Pg.128]    [Pg.205]    [Pg.206]    [Pg.375]    [Pg.68]    [Pg.70]    [Pg.245]    [Pg.177]    [Pg.396]    [Pg.255]    [Pg.521]    [Pg.128]    [Pg.269]    [Pg.150]    [Pg.319]    [Pg.237]    [Pg.669]    [Pg.123]   