Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Traditional apparatus

Traditional Apparatus. The above reference need only be expanded to Include the common use of cylindrical culture vessels (1), in place of the spherical reaction flasks, for shear sensitive materials and simple boiling water type baths (2) as their heating medium. [Pg.439]

Traditional Apparatus. As indicated earlier, liquid delivery systems for controlled rate addition of monomers and initiators have tended to rely upon constant speed piston pumps (19) in which volumetric control is achieved by manual adjustment of stroke length, and monitoring is by discharge from measuring cylinders. [Pg.443]

Superior hardware to the traditional apparatus is readily available and in some cases microprocessor intelligence is being built into dedicated modules for say temperature or pumping control. Integration of such units has the potential of full automation. [Pg.452]

The traditional apparatus of statistical physics employed to construct models of physico-chemical processes is the method of calculating the partition function [17,19,26]. The alternative method of correlation functions or distribution functions [75] is more flexible. It is now the main method in the theory of the condensed state both for solid and liquid phases [76,77]. This method has also found an application for lattice systems [78,79]. A new variant of the method of correlation functions - the cluster approach was treated in the book [80]. The cluster approach provides a procedure for the self-consistent calculation of the complete set of probabilities of particle configurations on a cluster being considered. This makes it possible to take account of the local inhomogeneities of a lattice in the equilibrium and non-equilibrium states of a system of interacting particles. In this section the kinetic equations for wide atomic-molecular processes within the gas-solid systems were constructed. [Pg.370]

The study was performed with a Class 1 member in the form of tablets. Changes in pH have no effects while changes in agitation intensity for USP apparatus II and IV have shown clear influences on the tablet erosion and subsequently on its release. Finally to simulate the fasted and fed state in vivo, fasted state stimulated intestinal fluid(Fassif) and fed state simulated intestinal fluid(Fessif) media were used. None of the USP traditional apparatus show a clear relationship with the in vivo results, especially in the fed conditions. In vitro data obtained by the ADS in the fasted state were consistent with those in vivo, as well as in the fed state after a slight time adjustment allowed in the FDA notes of guidance. A Level A of IVIVC was easily established with a good correlation coefficient in the fasted and fed states, respectively. The main results are presented in Fig. 13. [Pg.2074]

On-Hne Procedures The growing trend toward automation in industry has resiilted in many studies of rapid procedures for generating size information so that feedback loops can be instituted as an integral part of a process. Many of these techniques are modifications of more traditional methods. The problems associated with on-line methods include allocation and preparation of a representative sample analysis of the sample evaluation of the results. The interface between the measuring apparatus and the process has the potential of high complexity, and consequently, high costs [Leschonsld, Paiticle Cha racterization, 1, 1 (July 1984)]. [Pg.1828]

The surface forces apparatus (Section 2.3) enables the estimation of a surface energy term, Fq (Eq. 9), providing sufficiently smooth surfaces can be produced. In recent years Chaudhury, Pocius and colleagues have made a valuable contribution to the field of adhesion by developing the technique to study energies of adhesion and of surface energies of polymers [81-85]. These SFA results provide alternatives to values based on traditional destructive tests or contact angle measurements. [Pg.340]

The analysis of flue gas provides a measure of the efficiency of the combustion process and is given in percentages by volume. Traditionally, flue gas measurements have been taken using an Orsat apparatus, although in many industrialized countries this device has long been superseded by a wide variety of very accurate, portable, and precalibrated electronic equipment. [Pg.691]

The main limitation of HEX reactors is the short residence time, typically from a few seconds to a few minutes. Indeed, the apparatuses are smaller than the traditional ones and fast flow velocities are necessary in order to maintain good level of heat-transfer coefficients. However, as described in the previous paragraph, the highlighted transfer properties of HEX reactors allow us to operate in a few minutes, whereas it takes many hours in batch or semibatch mode. [Pg.263]

Accurate mass assignment of highly resolved ion-intensity signals remains problematic. QITMS is a relatively simple and compact apparatus (benchtop) and an order of magnitude less expensive than the multistage (triple quad or tandem double-focusing) instruments traditionally used for structural determination. [Pg.394]

The preparation of imines, enamines, nitroalkenes and N-sulfonylimines proceeds via the azeotropic removal of water from the intermediate in reactions that are normally catalyzed by p-toluenesulfonic acid, titanium(IV) chloride, or montmorillonite K 10 clay. A Dean-Stark apparatus is traditionally used which requires a large excess of aromatic hydrocarbons such as benzene or toluene for azeotropic water elimination. [Pg.192]

A traditional term applied to almost any apparatus in which the process of vulcanisation is carried out. It is not normally applied to a daylight press. [Pg.71]

Find the needle valve. This is at the base of the burner. Turn it fully clockwise (inward) to stop the flow of gas completely. If your burner doesn t have a needle valve, it s a traditional Bunsen burner and the gas flow has to be regulated at the bench stopcock (Fig. 58). This can be dangerous, especially if you have to reach over your apparatus and burner to turn off the gas. Try to get a different model. [Pg.134]


See other pages where Traditional apparatus is mentioned: [Pg.152]    [Pg.35]    [Pg.152]    [Pg.35]    [Pg.118]    [Pg.480]    [Pg.1365]    [Pg.23]    [Pg.212]    [Pg.48]    [Pg.54]    [Pg.132]    [Pg.261]    [Pg.54]    [Pg.7]    [Pg.7]    [Pg.29]    [Pg.761]    [Pg.71]    [Pg.71]    [Pg.256]    [Pg.45]    [Pg.141]    [Pg.55]    [Pg.50]    [Pg.281]    [Pg.36]    [Pg.210]    [Pg.233]    [Pg.321]    [Pg.8]    [Pg.547]    [Pg.186]    [Pg.27]    [Pg.83]    [Pg.20]    [Pg.94]    [Pg.184]   
See also in sourсe #XX -- [ Pg.439 , Pg.441 ]




SEARCH



© 2024 chempedia.info