Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Three-term control action

A description of the control action of a typical industrial three term controller is given in Section 7.7.2. [Pg.570]

Unlike simple data logging systems, supervisory control systems are designed to restrict the flexibility of the operator by "supervision" of his actions. In these systems the operator can interact with the plant through the keyboard/workstation to start or stop pumps, open valves and change PID controller set points. The three-term controllers may be conventional electronic controllers, linked to the supervising system, or software algorithms programmed into a PLC. [Pg.221]

A PID controller is the controller that is used most frequently in the process industries. The controller has three terms or actions ... [Pg.457]

Proportional plus integral plus derivative action Proportional action provides a controller output proportional to the error signal. Integral action supplies a controller output which changes in the direction to reduce a constant error. Derivative action provides a controller output determined by the direction and rate of change of the deviation. When all these are combined into one controller (three-term or PID), there is an automatic control facility to correct any process changes. [Pg.279]

CCTV technology is used to analyze digital images and identify the characteristics of a fire. CCTV can provide both a control action and display the picture in a staffed control room. The latter has a particular benefit as it allows very rapid incident assessment and also reduces the need for personnel to enter the area to investigate the fire conditions. In general terms, the CCTV flame detection system is comprised of three basic components the camera/detection element, the control panel, and the display computers. [Pg.192]

PID action should be employed for systems which respond rather sluggishly. The presence of the derivative term allows a higher proportional gain to be used which will speed up the control action. Such controllers are frequently installed because of their versatility and not because analysis of the system has indicated the need for the presence of all three modes of control. [Pg.570]

The relationship involves three terms and three adjustable parameters, the controller gain, Kc, the integral time, xl3 and the derivative time, Td (hence the name). Finding the right values of these parameters for the best possible control action is called tuning. There are several techniques available for controller tuning as will be discussed later. [Pg.257]

Then the two parameters, co and Cj, are determined for the optimal condition max xg(z). This still requires a search technique to obtain the values of Cq and Cl, but it was found that these computations were much simpler than the completely rigorous optimization. Actually, further terms in dx /dr and J Xqdx gave better results than the linear function, and are based on standard three-mode process controller actions however, we will not pursue this further here. [Pg.384]

A three point control configuration based on a proportional-integral controller with dynamic estimation of unknown disturbances was implemented in a Petlyuk column. The proposed controller comprises three feedback terms proportional, integral and quadratic actions. The first two terms act in a similar manner as the classical PI control law, while the quadratic term (double integral action) accounts for the dynamic estimation of unknown disturbances. Comparison with the classical PI control law was carried out to analyze the performance of the proposed controller in face to unknown feed disturbances and set point changes. The results show that the closed-loop response of the Petlyuk column is significantly improved with the proposed controller. [Pg.515]

In the reactor core there are 90 control members of the control and protection system. Each control member includes 3 absorber assemblies. The absorber assemblies are located in the central tubes of 270 fuel assemblies. The absorber assemblies consist of 16 absorber elements placed in the circle at regular intervals. The absorber material is vibro-packed powder of boron carbide (B4C). By using a special cross-bar, the absorber assemblies in three adjacent fuel assemblies are united in the control member of the CPS. Each control member of the CPS can be moved inside the reactor by an individual drive, which is independent in terms of the control action. The travel distance of the CPS control member is 2600 mm. [Pg.305]

By monitoring the validation status of the applied analytical procedure, for example, with control charts, reliable information on the long-term behavior of the procedure can be obtained and trends can be detected very early. Transferring in this way data to information to knowledge, the analytical system (or the production process) can be adjusted before problems such as OOS results occur (action instead of reaction). In analogy to equipment qualification, a continuous system is proposed design, operational, and performance validation (three Vs). [Pg.112]

There is no general true answer. However, your efforts will be of no avail if you cannot convince the staff. Other quickly established actions, which are free or cheap, are the date and signature regulation, the date regulation for chemicals, the control charts and the protection of electronic data. Certification or accreditation are long-term goals with a time frame of one to three years. [Pg.320]


See other pages where Three-term control action is mentioned: [Pg.327]    [Pg.382]    [Pg.234]    [Pg.29]    [Pg.174]    [Pg.53]    [Pg.563]    [Pg.123]    [Pg.157]    [Pg.27]    [Pg.308]    [Pg.136]    [Pg.271]    [Pg.29]    [Pg.902]    [Pg.569]    [Pg.431]    [Pg.370]    [Pg.425]    [Pg.421]    [Pg.15]    [Pg.222]    [Pg.123]    [Pg.2992]    [Pg.635]    [Pg.236]    [Pg.112]    [Pg.186]    [Pg.165]    [Pg.221]    [Pg.126]    [Pg.185]    [Pg.23]    [Pg.288]    [Pg.902]    [Pg.279]    [Pg.78]   
See also in sourсe #XX -- [ Pg.89 ]




SEARCH



Control action

Three term controller

© 2024 chempedia.info