Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

The Radiation Source

The principles of gamma-ray radiography are the same as X-ray radiography except that a radioisotope is used as the radiation source rather than an X-ray tube. [Pg.181]

Equations 1 and 2 shows that the distance b between the radiation source and the object has big influence on the X-ray image [8]. Therefore you have to find a compromise between a small geometrical unsharpness and a sufficient high magnification to archive an optimal... [Pg.544]

The GAMMASCAN 1500 HR is a combined system for two-dimensional (2D-CT) and three-dimensional (3D-CT) computed tomography, as well as digital radiography (DR). The system is equipped with two separate detector systems for the fan-beam and cone-beam CT. The sire of the objects is limited to a height of four meters, maximum diameters of 1.5 meters and a weight of up to 15 tons. The turntable which carries the test samples can be moved along and across the beam direction ( X- and Y- direction). The radiation source and the detector systems can be moved in Z- direction, both, simultaneously and independently. [Pg.584]

Turbidimetry and nephelometry are two related techniques in which an incident source of radiation is elastically scattered by a suspension of colloidal particles. In turbidimetry, the detector is placed in line with the radiation source, and the... [Pg.441]

For pipelines in service in chemical plants, it is not usually convenient to place a radiation source inside the pipe and position it to irradiate each welded joint. The radioisotope source container maybe placed on the outer surface of the pipe. The radiation beams then pass through two pipe wall thicknesses to expose films placed diametrically opposite the radiation source, also on the outside of the pipe wall. Other methods, such as magnetic particle inspection of welds in steel pipe, or ultrasonic inspection of welds in pipes of all materials, supplement x-rays in many critical appHcations. The ultrasonic tests can often detect the thin, laminar discontinuities parallel to the pipe surface or the incomplete fusion discontinuities along the weld... [Pg.129]

Ra.dia.tlon Shielding. Like lead, bismuth absorbs radiation. Therefore, bismuth ahoys are widely used in the medical industry during radiation therapy. The ahoy is molded to the shape of various organs that are to be shielded. Then the molds are placed between the radiation source and the patient to protect the patient s vital organs from radiation exposure. [Pg.125]

The effect of radiation-source temperature on the low-temperature absorptivity of a number of additional materials is presented in Fig. 5-12. It will be noted that polished aluminum (cui ve 15) and anodized (surface-oxidized) aluminum (cui ve 13), representative of metals and nonmetals respectively, respond oppositely to a change in the temperature of the radiation source. The absorptance of surfaces for solar... [Pg.572]

The total absorptance shows a decrease with increase in temperature of the radiation source similar to the decrease in emittance with increase in the specimen temperature. [Pg.573]

It is assumed that the target surface faces toward the radiation source so that it receives the maximum incident flux. The rate of combustion depends on the release. For a pool fire of a fuel with a boiling point above the ambient temperature (Tg), the combustion rate can be estimated by the empirical relation ... [Pg.60]

Both factors depend on the respective partial vapor pressures of water and carbon dioxide and upon the distance to the radiation source. The partial vapor pressure of carbon dioxide in the atmosphere is fairly constant (30 Pa), but the partial vapor pressure of water varies with atmospheric relative humidity. Duiser (1989) published graphs plotting absorption factors (a) against the product of partial vapor pressure and distance to flame (Px) for flame temperatures ranging from 800 to 1800 K. [Pg.63]

It follows that the more powerful the radiation source, the greater will be the sensitivity of the technique. [Pg.783]

Radiation exposure can be reduced by placing the radiation source or the potential target behind a shield that captures the radiation. During exposure to X rays for dental imaging, the patient wears a lead-lined pad, because X rays are absorbed more effectively by lead than by any other material. A lead shield a few millimeters thick is sufficient to stop X rays. [Pg.1601]

Fig. 3.19 Schematic illustration of the measurement geometry for Mossbauer spectrometers. In transmission geometry, the absorber (sample) is between the nuclear source of 14.4 keV y-rays (normally Co/Rh) and the detector. The peaks are negative features and the absorber should be thin with respect to absorption of the y-rays to minimize nonlinear effects. In emission (backscatter) Mossbauer spectroscopy, the radiation source and detector are on the same side of the sample. The peaks are positive features, corresponding to recoilless emission of 14.4 keV y-rays and conversion X-rays and electrons. For both measurement geometries Mossbauer spectra are counts per channel as a function of the Doppler velocity (normally in units of mm s relative to the mid-point of the spectrum of a-Fe in the case of Fe Mossbauer spectroscopy). MIMOS II operates in backscattering geometry circle), but the internal reference channel works in transmission mode... Fig. 3.19 Schematic illustration of the measurement geometry for Mossbauer spectrometers. In transmission geometry, the absorber (sample) is between the nuclear source of 14.4 keV y-rays (normally Co/Rh) and the detector. The peaks are negative features and the absorber should be thin with respect to absorption of the y-rays to minimize nonlinear effects. In emission (backscatter) Mossbauer spectroscopy, the radiation source and detector are on the same side of the sample. The peaks are positive features, corresponding to recoilless emission of 14.4 keV y-rays and conversion X-rays and electrons. For both measurement geometries Mossbauer spectra are counts per channel as a function of the Doppler velocity (normally in units of mm s relative to the mid-point of the spectrum of a-Fe in the case of Fe Mossbauer spectroscopy). MIMOS II operates in backscattering geometry circle), but the internal reference channel works in transmission mode...
Both fixed and variable wavelength uv/visible detectors are available. The variable types use a deuterium and/or a tungsten filament lamp as the radiation source and can operate between about 190-700 nm. They will have a number of absorbance ranges (ranges are given... [Pg.53]

It is clear from this discussion that the dose requirement and unit cost will be lower if the material has a higher molar mass M and the reaction has a high G value. Thus, the best candidates will be a polymeric material and a chain reaction. Quite often, a free-radical irradiation is used. The radiation source of choice is usually a 60Co - y facility, although electron beam irradiation is also used. Since most radiation-chemical reactions used in industry can also be brought about by other conventional means such as thermal, or photochemical processes, the processing cost must be below 10irradiation cost one has to include the cost of operation, maintenance, and the like. (Danno, 1960). [Pg.366]

A thermopile sensor generates an output voltage that depends on the temperature difference between its hot and cold contacts. For infrared temperature measurement, the hot contacts are normally thermally insulated and placed on a thin membrane, whereas the cold contacts are thermally connected to the metal housing. Infrared radiation, which is absorbed by the hot contacts of the thermopile, causes a temperature difference between hot and cold contacts. The resulting output voltage is a measure for the temperature difference between radiation source and cold contacts of the thermopile sensor. It is therefore necessary to measure also the temperature of the cold contacts by an additional ambient temperature sensor in order to determine the temperature of the radiation source. [Pg.74]


See other pages where The Radiation Source is mentioned: [Pg.442]    [Pg.442]    [Pg.191]    [Pg.195]    [Pg.403]    [Pg.221]    [Pg.308]    [Pg.743]    [Pg.391]    [Pg.1028]    [Pg.1033]    [Pg.21]    [Pg.286]    [Pg.509]    [Pg.788]    [Pg.791]    [Pg.33]    [Pg.861]    [Pg.515]    [Pg.264]    [Pg.391]    [Pg.19]    [Pg.313]    [Pg.279]    [Pg.271]    [Pg.31]    [Pg.278]    [Pg.252]    [Pg.60]    [Pg.65]    [Pg.108]    [Pg.29]    [Pg.425]    [Pg.74]   


SEARCH



Energy Balances for Volume Zones—The Radiation Source Term

Radiation sources

THE SOURCES

The Source of Radiation

The Sun as Radiation Source

© 2024 chempedia.info