Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Test cell preparation

Phase 2. Test Cell Preparation. Test cell preparation involved raising berms for experimental and control cells, one each, at the Erie Pier CDF. Berms were constructed using dredged material that is already in the CDF. The test cells were anticipated to provide a minimum containment volume of 382 m (500yd ) each with approximate dimensions of 2-m (6-ft) depth by 27 m (90 ft) by 7 m (24ft), based on the amount dredged. [Pg.673]

Supercapacitor Test Cell Preparation (Design and Structure).276... [Pg.275]

SUPERCAPACITOR TEST CELL PREPARATION (DESIGN AND STRUCTURE)... [Pg.276]

Peter and Wang [266] invented a channel flow cell for rapid growth of CdTe films they showed that 2 p,m Aims can be deposited in less than 20 min, as opposed to the 2-3 h normally required in the conventional stirred single batch cells. The as-deposited films were structurally more disordered than the conventional ones, but after annealing and type conversion they became suitable for fabrication of efficient solar cells. A test cell with an AMI.5 efficiency approaching 6% was fabricated using a film prepared in the channel cell. [Pg.139]

Initial experiments showed that [0s(ri6-bip)Cl(en)]+ (26) was not cytotoxic towards cancer cells (105), but a later reassessment of the cytotoxic activity of this compound showed that it indeed was active at micromolar concentrations (IC50 values of 7.6 (A2780) and 10 pM (A549)) (112). A possible explanation for the initial lack of activity may be the partial decomposition of the complex in stock test solutions prepared in DMSO, as was evidenced in subsequent studies (112). The cytotoxicity data are now more in line with the chemical properties of the complex, i.e. observed hydrolysis rate and guanine binding. [Pg.54]

A new desiccant formulation was prepared from a mixture of submicron-sized silica gel and molecular sieves to achieve the best combination of large water capacity, rapid moisture adsorption and easy regenerability. The formulation also tolerates the presence of VOCs and smokes. Commercial NaX and silica gel were crushed and mixed in the proportion of 1 2 and wash coated on a monolith for testing. The same test cell shown in Fig. 12.7-2 was used. The airflow to the saturator was adjusted to obtain the desired humidity in the feed air. Humidity sensors located at the flow cell inlet and outlet, were used to... [Pg.378]

Before further testing and to confirm that the compounds are cytotoxic rather than merely interfering with the Alamar blue indicator dye, they are re-bioassayed using two other indicator dyes. Calcein-AM is a fluorescent dye that measures changes in cell mem brane permeability, an indicator for one of the penultimate steps of cell death, uci e e measures the amount of adenosine triphosphate (ATP) synthesis in a chemilurmne assay. For some compounds, cell death was also confirmed by microscopic exami Papanicolaou-stained cell preparations.11... [Pg.155]

Recent work [64] by Kiljunen and Kanerva has been directed towards the search for novel sources of (R)-oxynitrilases which may transform bulky aryl aldehydes. For this purpose whole cell preparations (called meal) from apple seeds and cherry, apricot and plum pips were tested for their (R)-cyanohydrin activity. In this study a comparison of almond and apple meal showed that they possess similar properties for the formation of the (R)-stereogenic centre. However, in certain cases higher enantioselectivity was observed using the apple meal preparation. Additionally, apple meal (R)-Hnl has also been applied to transform ketones into their corresponding cyanohydrins [65] thus creating a wider repertoire of substrates for this latest of (R)-Hnls. Thus it has only recently been shown that apple meal (R)-oxynitrilase is now an additional member of the (R)-Hnl family. [Pg.41]

There are certain specimen preparations that create problems for some of the sandwich methods. Frozen or fresh cell preparations may have inherent avidin-binding properties, as some fixed preparations can have. While this should not preclude the use of these methods, one should be aware of the potential limitations and have alternate methodologies available for confirmatory testing. [Pg.188]

Before analyzing the samples, set the flnorescence amplifier gain on linear-scale detection and test an nnstained sample of the cell preparation to determine the... [Pg.302]

Systematic investigations were carried out for the preparation of cellulose acetate of D.S. 2,65 and other mixed esters which included cellulose acetate-propionate, cellulose acetate-butyrate, cellulose acetate-benzoate and cellulose acetate-methacrylate. The experimental conditions were optimised for maximum yield of the ester. Flat osmotic membranes were developed from these esters and characterised for their osmotic and transport properties. The nmmbra-nes were evaluated in a reverse osmosis laboratory test-cell using 5OOO ppm sodium chloride solution at 40 bars pressure. Table 1 presents the typical performance data of these membranes. [Pg.294]

In vitro In glassware, tests with isolated tissue or with cell preparations. [Pg.130]

Most studies of biocatalysis in ionic liquids have been concerned with the use of isolated enzymes. It should not be overlooked, however, that the first report on biocatalysis and ionic liquids involved a whole-cell preparation Rhodococcus R312 in a biphasic [BMIm][PF(s]-water system [7]. It was shown, using a nitrile hydrolysis test reaction, that the microorganism maintained its activity better in ionic liquid than in a biphasic toluene-water system. [Pg.236]

Preparation of test specimens from solid samples invariably requires a portion of the sample to be cut out, for example, from the middle of the original roll or sheet of material. Freshly cut edges are notoriously high emissions sources and failure to adequately seal these and exclude them from the test is a major potential source of error. (Another advantage of emission test cells versus conventional chambers is that they automatically exclude any potential edge effects in most cases.) Similarly, surface emissions testing requires the rear surface of the material (the surface that will not be exposed once the product is installed in a building) to be sealed and excluded from the test. This is always a consideration for emission test chambers but can be an issue for both cells and chambers in the case of porous or permeable materials. [Pg.140]

Recording Absorptiometers. At least two types are available. In the first unit there are two test sample cells and one standard reference cell. Successive samples are metered alternately into the two test cells. While the cell containing one sample is being read and recorded, the other cell is being automatically rinsed in preparation for arrival of the succeeding sample. [Pg.337]

Cells were prepared from healthy, confluent Vero and Hep2 cell cultures that were maintained by passage every 3-4 days. One day prior to the test cells were released from the cultures using standard techniques and suspended in a growth medium and dispensed into wells of a microtiter plate and placed in a 5% C02 incubator at 37 2° C. An aliquot (100 pi) of each test substance was introduced into a well (in triplicate) with 100 pi of PBS as a control. Every 24 hrs the wells were examined under high power of an inverted microscope to check for any cytopathic effect (CPE). [Pg.15]

AKP-30 supports were prepared as described in chapter 4. After firing the supports were machined to the required dimensions and polished until a shiny surface was obtained. For low temperature measurements, up to 300°C, the supports were used without any further sealing. The membranes were sealed with Kalrez or PTFE O-rings in a K250 testing cell. For the... [Pg.91]

Prepare blanks by transferring 2.00 mL of Sample Preparation, Procedure 2, into separate 20- x 150-mm glass test tubes. Prepare Reagent Blanks by transferring 2.00 mL of water into a series of five separate 20- x 150-mm glass test tubes. Add 4.0 mL of Color/Stop Solution to all blank tubes and mix. Next add 4.0 mL of Substrate Solution, and mix. Determine the absorbance of each solution at 415 nm in a 1-cm path-length cell with a suitable spectrophotometer, using water to zero the instrument. [Pg.922]


See other pages where Test cell preparation is mentioned: [Pg.421]    [Pg.317]    [Pg.421]    [Pg.317]    [Pg.1376]    [Pg.303]    [Pg.249]    [Pg.521]    [Pg.110]    [Pg.27]    [Pg.1]    [Pg.308]    [Pg.312]    [Pg.107]    [Pg.395]    [Pg.282]    [Pg.258]    [Pg.100]    [Pg.100]    [Pg.113]    [Pg.233]    [Pg.148]    [Pg.65]    [Pg.319]    [Pg.22]    [Pg.343]    [Pg.826]    [Pg.172]    [Pg.175]    [Pg.400]    [Pg.173]    [Pg.101]    [Pg.460]    [Pg.461]   
See also in sourсe #XX -- [ Pg.673 ]




SEARCH



Cell preparation

Test preparation

Testing test cells

Testing, cell

© 2024 chempedia.info