Temperature measurement double-differential

Pressure-Compensated Temperature Multicomponent Compositions Computed from Temperature and Pressure Measurements Double-Differential Temperature Average Temperature Composition Estimators... [Pg.560]

If the measured ripple current is confirmed to be within the rating, we can then take the case temperature measurement as the basis for applying the normal 10°C doubling rule, even if the heat is coming from adjacent sources. Again, that is only because the case to core temperature differential is actually within the capacitor s design expectations. [Pg.106]

The first historical calorimeters of this type were manually-operated (see Figure 6). Person, in 1849 decided to cancel die temperature difference Ts - TV which he could measure by means of a double-bulb differential thermometer. For this puipose, he made use of a second, external, water bath, at a higher or lower temperature, in which he could partly immerse the water thermostat surrounding the system. He adjusted the depth of immersion by means of the crank visible in the drawing. He called his set-up a cancelled heat-loss calorimeter [21]. This is the first known active adiabatic calorimeter. [Pg.32]

The sensitivity of a thermocouple is related to the voltage generated. The voltage is greater for a larger temperature differential it is 5.269 mV for a Type J thermocouple measuring a temperature of 100 and approximately double that at 200 °C. To increase the sensitivity, thermocouples may be connected in series and this series connection is referred to as a thermopile. [Pg.184]

A differential conductance measurement of the double-island device at Uquid He temperatures is shown in Figure 5.49a. In this case, due to Coulomb blockade the conductance is suppressed in the region of Vds = 0. The Coulomb charging energy was calculated from the size of the diamonds, and had a value 20 meV, which was in good agreement with that obtained from the simulation of the conductivity expected for such a described device. The basic model for this simulation and the conductance plot are shown in Figure 5.49b and c. [Pg.431]

The process flow for the fabrication of the microfluidic system includes a single or double metallization layer, a polymer layer for the fluidic system, and a glass sealing cap. There have been some efforts during fabrication to minimize the thermal-dissipation loss. The temperature difference between the two points where the sensors are located is measured with a differential current amplifier, and the flow rate is calibrated. At low flow rates, the temperature difference is a linear function of the flow rate as in Fig. 6. Measurements without heat insulation decrease the sensitivity of the flow sensor and increase the lower limit of flow rate detection. The distance between the heater and the sensors is optimized for the maximum differential temperature. [Pg.1162]

Differential thermal analysis measurements indicated double TgS for solutions with lower polymer concentrations beyond the depicted cusp in Fig. 12.10 [59]. Creep recovery measurements on this system showed that the solvent molecules in the solutions have higher mobilities than the polymer chain segments. A lower temperature and greater crowding is therefore necessary to force the solvent molecules from an equilibrium response. Therefore, it was... [Pg.191]

The fluid static pressures were measured with calibrated Bourdon tube gages, and the differential pressures were measured with mercury-filled, double-legged glass manometers. These pressure measuring instruments were located on a single panel and their indications were recorded photographically. The fluid and wall temperatures were measured with copper-constantan thermocouples and recorded on multipoint temperature recorders. [Pg.381]


See other pages where Temperature measurement double-differential is mentioned: [Pg.235]    [Pg.741]    [Pg.91]    [Pg.650]    [Pg.339]    [Pg.91]    [Pg.472]    [Pg.562]    [Pg.222]    [Pg.225]    [Pg.235]    [Pg.557]    [Pg.230]    [Pg.100]    [Pg.553]    [Pg.150]    [Pg.128]    [Pg.91]    [Pg.161]    [Pg.57]    [Pg.123]    [Pg.803]    [Pg.43]    [Pg.226]    [Pg.213]    [Pg.296]    [Pg.1299]    [Pg.81]    [Pg.280]    [Pg.278]    [Pg.337]    [Pg.299]    [Pg.299]    [Pg.744]    [Pg.768]    [Pg.135]    [Pg.64]    [Pg.381]    [Pg.248]    [Pg.330]    [Pg.383]   
See also in sourсe #XX -- [ Pg.240 ]