Taper gauges

Tools most commonly used for alignment procedures are dial indicators, adjustable parallels, taper gauges, feeler gauges, small-hole gauges, and outside micrometer calipers. [Pg.915]

The extended jaws of a vernier caliper gauge are used to measure the bore or inside diameter of mbes in the same way. The bore of small diameter and capillary tubes can easily be measured with a taper gauge (Fig. 2.2). [Pg.7]

FIG. 2.2. (Down) Tapered gauge for measuring tlie bore of small diameter and capillary tubes. Tliis gauge will give accurate readings when inserted in tubing witli straight cut ends. [Pg.8]

Taper gauges are used to check the male and female features of tapered workpieces. A taper ring gauge is used to check the male work-piece feature, i.e. a shaft while a taper plug gauge is used to check the female workpiece feature, i.e. a hole - Fig. 5.15. [Pg.78]

A taper gauge is used to check the correctness of the angle of taper of the workpiece and also to check the diameter at some point on the taper, usually the large diameter of a female feature and the small diameter of a male feature. [Pg.78]

T - Taper S - Shoulder G - Gauge A-All Areas/Rows M - Middle Row H - Heel Row... [Pg.810]

The location of the primary dull characteristic is described in the fourth space. There are six choices cone, nose, taper, shoulder, gauge, and all areas. Figure 4-167 shows four possible fixed cutter bit profiles with the different areas labeled. It is recognized that there are profiles for which the exact boundaries between areas are debatable and for which certain areas may not even exist. Notice that in the bottom profile there is no taper area shown. However, using Figure 4-167 as a guide, it should be possible to clearly define the different areas on most profiles. [Pg.811]

Water issues from the nozzle of a horizontal hose-pipe. The hose has an internal diameter of 60 mm and the nozzle tapers to an exit diameter of 20 mm. If the gauge pressure at the connection between the nozzle and the pipe is 200 kPa, what is the flow rate The density of water is 1000 kg/m3. [Pg.15]

The actuation chamber is made from stainless steel. It houses the canister within its adapter sleeve during dosing. A smooth surface provides a face seal between canister valve stem tip and sample injection passage. The close tolerance between the external wall of the adapter and the internal wall of the actuation chamber induces a partial vacuum which creates a controlled pumping action causing sample methanol to flush the injection passage after each dose. A replaceable 16 gauge needle fits onto a standard luer tapered tip. [Pg.192]

Straight Pipe Threads These are confined to light-weight couplings in sizes 2 in and smaller (Fig. 10-132). Manufacturers of threaded pipe ship it with such couplings installed on one end of each pipe. The joint obtained is inferior to that obtained with taper threads. The code limits the joint shown in Fig. 10-129 to 1.0 MPa (150 Ibftin ) gauge maximum, nontoxic fluids. [Pg.81]

Each of the above was manufd in variant forms. These variants incorporate a number of changes from the basic, including case taper differences, size of primer, wall thickness, type of flechette and tracer. In addition the basic forms (and probably some of the variants too) were produced in proof and dummy loadings The potential of multi-flechette loadings was realized early, and AAI tried, in 1957, a multi-flechette cartridge based on a 12 gauge shotgun... [Pg.429]

The stainless steel stripper column stood about 82 ft. (25 m) tall, which included a column skirt base of about 15 ft. (4.6 m) tall. The stripper collapsed in the lower 9-ft. diameter (2.7 m) section just below the conical transition section that tapered down to connect with the upper 5A ft. (1.7 m) diameter section. The vessel was designed to operate about 5 psig (34.5 kPa gauge) and was mechanically rated for about 25 psig (173 kPa gauge). [Pg.62]

When health care providers decide to supervise withdrawal from psychiatric drugs, they must pay careful attention to the feelings or emotions of their patients or clients. Not only do patients deserve this respect and concern, their emotional reactions are the best gauge of how well the tapering process is going. Drug withdrawal requires a patient-centered approach. [Pg.411]

The PBT/PBA copoly(ester ester) was injection molded into dogbone tensile specimens. The cross-section in the tapered area of the specimen is 4 mm x 10 mm. ITie gauge length is 50 mm. [Pg.118]

We employed the Cahn RG electrobalance in the glass vacuum bottle manufactured by Cahn. Three 40/35 standard taper connections are attached to the bottom of the bottle. One outer one is for the counterweights, the other we used for the sample of chromia, which was contained in a gold cup hung from a Nichrome wire attached to the beam of the balance. A 30-liter ion pump and a discharge gauge were connected to the center connection. [Pg.19]


See other pages where Taper gauges is mentioned: [Pg.335]    [Pg.22]    [Pg.78]    [Pg.79]    [Pg.73]    [Pg.47]    [Pg.335]    [Pg.22]    [Pg.78]    [Pg.79]    [Pg.73]    [Pg.47]    [Pg.454]    [Pg.344]    [Pg.953]    [Pg.21]    [Pg.312]    [Pg.224]    [Pg.312]    [Pg.179]    [Pg.222]    [Pg.117]    [Pg.19]    [Pg.20]    [Pg.828]    [Pg.318]    [Pg.551]    [Pg.80]    [Pg.244]    [Pg.629]    [Pg.542]    [Pg.184]    [Pg.144]    [Pg.422]    [Pg.201]    [Pg.20]   
See also in sourсe #XX -- [ Pg.78 ]