Internal floating roof good venting maximizes tank capacity... [Pg.312]

For liquid raw materia hias= ttlifiS OOI oil VgC(l uisidsitk)fitorage tank capacities and ask operators when a tank was last filled. Monitor the tank levels and the... [Pg.365]

For tanks with a capacity of 20,000 barrels or more, the requirements for the vacuum condition are very close to the theoretically computed value of 2 cubic feet of air per hour per square foot of total shell and roof area. For tanks with a capacity of less than 20.000 barrels, the requirements for the vacuum condition have been based on 1 cubic foot of free air per hour for each barrel of tank capacity. This is substantially equivalent to a mean rate of vapor-space-temperature change of 1(X)F per hour. [Pg.470]

Tank Capacities, Horizontal Cylindrical-Contents of Tanks with Flat Ends When Filled to Various Depths... [Pg.609]

Additional information regarding applicator-boom width, spray-tank capacity, and the wheelbase of any vehicle-mounted soil sampling equipment used during the study is also required to ensure that the field plot design accommodates size restrictions of field equipment. [Pg.853]

In particular results on tank capacity are a typical output of simulations on the plant engineering level. It could be argued that these results may be obtained without simulation as well and this is true as long as the stochastic impact on supply and demand is within certain boundaries. As soon as the facility needs to be able to handle stochastic supply and demand with significant variations static calculations reach their limits. These limitations become even more critical if a multi-product process is analyzed as quite often is the case. [Pg.29]

Storage tank Tank capacity, type, and storage pressure... [Pg.608]

From a shop-fabricated tank manufacturer s perspective, a diked AST generally refers to a steel tank within a factory-fabricated steel box, or dike. An example of a diked AST is the STl F911 standard, providing an open-topped steel rectangular dike and floor as support and secondary containment of a UL 142 steel tank. The dike will contain 110 percent of the tank capacity as rainwater may already have collected in the dike, the additional 10 percent acts as freeboard should a catastrophic failure dump a full tank s contents into a dike. Many fabricators offer steel dikes with rain shields to prevent precipitation from collecting. [Pg.143]

Figure 9 Kawagoe 3 4 Ultra Supercritical, Double Reheat Power Generation System fired with LNG from the Middle East and Indonesia. The largest gas power plant in the world with a rated power of 4.7 GW electric - having a LNG storage tank capacity of 120 000 m3 (Courtesy Kawagoe plant, Japan 2002)... Figure 9 Kawagoe 3 4 Ultra Supercritical, Double Reheat Power Generation System fired with LNG from the Middle East and Indonesia. The largest gas power plant in the world with a rated power of 4.7 GW electric - having a LNG storage tank capacity of 120 000 m3 (Courtesy Kawagoe plant, Japan 2002)...
Method. The developed chromatoplates are transferred to a plate rack and placed inside a sealed tank (capacity, 4 gallons) containing 6 g of ammonium bicarbonate in the bottom. The tank is placed in an oven and heated to 110-1 SO °C for 2-12 h (depending on the nature of the compounds and of the adsorbent). The tank is then removed from the oven and cooled to room temperature for plate removal and evaluation. Most spots have similar fluorescence spectra (excitation, 370-390 nm emission, 450-475 nm). For the best sensitivity, silica gel, alumina, Florisil or Kieselguhr should be used (after washing to remove as much of the inorganic impurities as possible). [Pg.183]

A storage tank for product nitric acid is a necessity on this plant. The tank should have the capacity to store one week of full acid production to allow for continued supply in the event of unscheduled shutdowns in the adjacent ammonium nitrate plant. This requires a minimum tank capacity of 1500 m3. However, it is recommended to increase the tank capacity so that an inventory of 450 m3 of product acid is always available within the tank for outside sales. This extra volume is equivalent to 20 standard road-tanker loads. The tank must be constructed of stainless steel type 304L ( nitric acid grade ), the specification of this material is given in Appendix D. The design data required for this unit are specified below. [Pg.216]


See other pages where Tanks capacity is mentioned: [Pg.52]    [Pg.455]    [Pg.308]    [Pg.312]    [Pg.726]    [Pg.210]    [Pg.125]    [Pg.264]    [Pg.512]    [Pg.170]    [Pg.297]    [Pg.466]    [Pg.470]    [Pg.481]    [Pg.481]    [Pg.643]    [Pg.359]    [Pg.297]    [Pg.466]    [Pg.470]    [Pg.470]    [Pg.481]    [Pg.481]    [Pg.281]    [Pg.281]    [Pg.335]    [Pg.285]    [Pg.22]    [Pg.35]    [Pg.336]    [Pg.16]    [Pg.308]    [Pg.312]    [Pg.12]   