Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Systems for determination

FIG. 21-63a Use of CAPE software system for determining carton, shipping case, and pallet load dimensions and patterns for defined conditions. Shipping cases must fit within the pallet dimensions. (Couttesy of CAFE Systems, Inc., Flano, TX, 800-229-3434.)... [Pg.1985]

Failure of Individual Control Valve - The following individual control valve failures should be included in the analysis of control systems for determination of pressure rehef requirements ... [Pg.132]

M. H. Liu, S. Kapila, K. S. Nam and A. A. Elseewi, Tandem supera itical fluid extr action and liquid cliromatogr aphy system for determination of chlorinated phenols in solid matrices , 7. Chromatogr. 639 151-157 (1993). [Pg.149]

Zebiihr et al. (29) developed an automated system for determining PAHs, PCBs and PCDD/Fs by using an aminopropyl silica column coupled to a porous graphitic carbon column. This method gives five fractions, i.e. aliphatic and monoaromatic hydrocarbons, polycyclic aromatic hydrocarbons, PCBs with two or more ortho-chlorines, mono-ort/io PCBs, and non-ortho PCBs and PCDD/Fs. This method employed five switching valves and was successfully used with extracts of sediments, biological samples and electrostatic filter precipitates. [Pg.343]

Elicks BB, Hosker Jr RP, Meyers TP, Womack JD. 1991. Dry deposition inferential measurement techniques. I. Design and tests of a prototype meteorological and chemical system for determining dry deposition. Atmos Environ 25A 2345-2359. [Pg.43]

Larsson and Degens [171] devised an automated system for determining carbohydrates in biological samples using partition chromatography for the separation and the orcinol colorimetric method for the final analysis. Later versions of this kind of autoanalyser, using tetrazolium blue or a Cu1 complex of bicinchoninate for the final measurement, have been reported [172]. [Pg.399]

Nevertheless, where it is difficult for a computer to learn expert system rules, the traditional expert system still has a place. A typical recent example of the use of expert systems is provided by the work of Dobrzanski and Madejski62 who have developed a prototype system for determining metal coating that provides an optimum combination of appearance, abrasion resistance, color, and other factors. A less scientific, but still intriguing, example of the use of these systems is HuskEval, an expert system for evaluating the quality of Siberian Huskies.63... [Pg.385]

Manes J, Font G, Pico Y. 1993. Evaluation of a solid-phase extraction system for determining pesticide residues in milk. J Chromatog 642 195-204. [Pg.271]

Moss, J. E., HR.5605, A Bill to Create a Comprehensive Federal System for Determining the Ownership of and Amount of Compensation to be Paid for Inventions Made by Employed Persons, Introduced into U.S. House of Representatives, 94th Congress, First Session, March 26, 1975. [Pg.33]

Neal RA, Croft SL. An in-vitro system for determining the activity of compounds against the intracellular amastigote form of Leishmania donovani. J Antimicrob Chemother 1984 14 463. [Pg.110]

FIGURE 3.9 Circulating water photoreactor system for determination of photomicro-biocidal activity under water flow conditions, a, reinforced membrane used in the study b, water jacket, continuous flow, infrared filter c, light source d, air pump e, bacterial air filter f, 3-way tap/pressure release g, 2-way taps h, frit for aeration J, peristaltic pump k, reservoir 1, ground glass Joints for ease of cleaning and sterilization (Bonnett et ai, 2006). [Pg.139]

Dasgupta, P. K., and V. K. Gupta, Membrane-Based Flow Injection System for Determination of SulfuKlV) in Atmospheric Water, Environ. Sci, Technol., 20, 524-526 (1986). [Pg.640]

Figure 6.1 Coordinate systems for determining scattering by an arbitrary particle in the Rayleigh-Gans approximation. [Pg.160]

ASTM E668 Standard Practice for Application of Thermoluminiscence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices... [Pg.265]

As we have already mentioned, to constmct the matrix H it suffices to find particular solutions of system (42). The system for determination of the function 0o reads as... [Pg.293]

FI) preconcentration system for determination of trace gold in ore samples was studied by simplex... [Pg.118]

E. I. Vereda Alonso, L. P. Gil, M. T. Siles Cordero, A. Garcia de Torres and J. M. Cano Pavon, Automatic on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry, J. Anal. At. Spectrom., 16, 2001, 293-295. [Pg.156]

A. Aouarram, M. D. Galindo-Riano, M. Garcia-Vargas, M. Stitou and F. El YoLisli, A permeation liquid membrane system for determination of nickel in seawater, Talanta, H, 2007, 165-170. [Pg.158]

Components of a biosensor system for determining the identity and concentration of biomolecule A. A is stoichiometrically converted to B by a specific enzyme in the reaction center. The concentration of B is measured by the sensor. [Pg.48]


See other pages where Systems for determination is mentioned: [Pg.107]    [Pg.123]    [Pg.732]    [Pg.386]    [Pg.378]    [Pg.8]    [Pg.453]    [Pg.499]    [Pg.306]    [Pg.1090]    [Pg.69]    [Pg.69]    [Pg.323]    [Pg.151]    [Pg.19]    [Pg.605]    [Pg.646]    [Pg.653]    [Pg.658]    [Pg.484]    [Pg.605]    [Pg.646]    [Pg.653]    [Pg.658]    [Pg.121]    [Pg.150]    [Pg.154]    [Pg.296]    [Pg.304]   


SEARCH



Advanced microelectrode systems for pH determination

Analytical Determination of ARR Residuals for Switched LTI Systems

Determination of the Required Reliability for Safety Instrumented Systems

Determine Pump Downtime for a System

System for the determination of phenoxyalkane carboxylic acids in water

System for the determination of phenylurea and herbicidal carbamates in water

© 2024 chempedia.info