Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Switches positive mode

Key switch positions. Mode switch interlocks for pulse, square wave, and manual and automatic operation. [Pg.52]

After all four positive scans are completed (typically within 3 s), the polarity is switched and the fifth scan event records a negative-ion full-scan MS. If the expected protonated molecule is not detected in the positive mode, the second, third and fourth scan events are skipped and the fifth (negative-ion-mode) scan event is triggered. Similar to the positive-ion mode, if the expected [M-H]- ion is detected in the full-scan MS, IT data-dependent MS/MS (sixth), FT accurate MS (seventh), and FT MS/MS (eighth) scan events are acquired. Clearly demonstrated here is the ability of the LTQ-FT to handle multiple experiments on a chromatographic time scale. One might question the need for such an elaborate data-dependent scheme when apparently all that is needed is an accurate mass determination followed by a data-dependent accurate mass MS/MS spectmm. Apart from the fact that using the... [Pg.199]

TABLE 5.3. Accurate Mass Measurements for a set of 30 Pharmaceutical Compounds Collected in Positive Ion Mode (Experimental Error in ppm Shown in Column 4), Negative Ion Mode (Experimental Error in ppm Shown in Column 5), and with Pos/Neg Switching (Data Shown in Columns 6 and 7, Respectively) Using a Lock Mass (LM) for Each Polarity, Reserpine, m/z = 609 for Positive Mode and Hippuric Acid, m/z 178 for Negative Mode... [Pg.205]

Combination of assembled microcell [134] or Au chip electrode [132] with a positive-intrinsic-negative (PIN) photodiode detector lead to advancement in the miniaturization of ECL instrumentation for DNA quantification. Though, noise level and sensitivity of sihcon PIN diode are less sensitive than a PMT [134]. A highly sensitive DNA biosensor, fabricated by self-assembling the ECL probe of thiolated hairpin DNA tagged with ruthenium complex on the surface of a gold electrode works on a switch-off mode and ECL intensity decreases with an increase of the concentration of target DNA, and a detection limit of 9 x 10 M... [Pg.134]

In the context of safety applications, there are two generic types of limit switch, known as positive mode and negative mode switches. These are shown in Figure 13.4, which illustrates the switch s plunger being moved by a rotating cam. The positive mode switch is safer than the negative mode... [Pg.204]

Which Mode Switch position causes the following conditions ... [Pg.470]

Which one of the following combinations of mode switch position, power, and transient rod drive positions permits firing of the transient rod ... [Pg.470]

Table 6.1 shows that all the devices mentioned allow electron ionization and chemical ionization in positive mode (Cl in positive mode is often optional). The internal ionization ion trap offers the double advantage of allowing the use of liquid reagents and rapid switching from one ionization mode to another. This clearly makes the internal ionization ion trap the perfect device for structural elucidation that requires easy access to both ionization modes. However, this analyzer is the only one that does not operate in negative chemical ionization for the reasons covered in Chapter 4. [Pg.109]

Under the manual detector positioning mode, only the safety limit switches are active in protecting the mechanical system. [Pg.274]

As one can notice, the boost-mode converter has the same parts as the forward-mode converter, but they have been rearranged. This new arrangement causes the converter to operate in a completely different fashion than the forward-mode converter. This time, when the power switch is turned on, a current loop is created that only includes the inductor, the power switch, and the input voltage source. The diode is reverse-biased during this period. The inductor s current waveform (Figure 3-4) is also a positive linear ramp and is described by... [Pg.24]

With P-donors a variety of different structures are formed. Two complexes (359a,b) with a five-coordinate square pyramidal geometry and one S-donor in the apical position are reported.934,933 In a related complex (360) the nickel center reveals a distorted square planar geometry, because one xanthate ligand switched to a monodentate coordination mode. 6 By reaction of [NiL2] complexes with Ph2P(CH2)2P(Ph)(CH2)2PPh2, compound (362) is formed, which consists of a five-coordinate cation and a hexacoordinate anion. 7... [Pg.333]

The M-A transfer switch has five positions that alter the mode of operation. The indication is provided by the deviation meter. [Pg.157]

AUTO. This is the normal position of the M-A transfer switch. It places the controller in the automatic mode of operation. Also, the deviation meter indicates any deviation between controlled variable and setpoint. [Pg.157]

The manual-automatic transfer switch is a five position switch that alters the mode of operation. [Pg.161]

One of the specificities of ToF-SIMS is the possibility to switch easily from positive to negative ion mode by reversing the extraction potential. The mass calibration of spectra is internal, using low mass ions (H+, H2+, H3+, C+, CH+, CH2+ and CH3+ ion peaks in... [Pg.434]


See other pages where Switches positive mode is mentioned: [Pg.82]    [Pg.239]    [Pg.24]    [Pg.358]    [Pg.76]    [Pg.214]    [Pg.27]    [Pg.249]    [Pg.265]    [Pg.510]    [Pg.566]    [Pg.23]    [Pg.719]    [Pg.207]    [Pg.492]    [Pg.81]    [Pg.86]    [Pg.450]    [Pg.66]    [Pg.308]    [Pg.66]    [Pg.308]    [Pg.115]    [Pg.389]    [Pg.349]    [Pg.130]    [Pg.44]    [Pg.169]    [Pg.276]    [Pg.740]    [Pg.58]    [Pg.20]    [Pg.112]   
See also in sourсe #XX -- [ Pg.204 , Pg.205 , Pg.207 , Pg.208 ]




SEARCH



Position Switching

Positive-negative polarity switching mode

© 2024 chempedia.info