Switches negative mode

TABLE 5.3. Accurate Mass Measurements for a set of 30 Pharmaceutical Compounds Collected in Positive Ion Mode (Experimental Error in ppm Shown in Column 4), Negative Ion Mode (Experimental Error in ppm Shown in Column 5), and with Pos/Neg Switching (Data Shown in Columns 6 and 7, Respectively) Using a Lock Mass (LM) for Each Polarity, Reserpine, m/z = 609 for Positive Mode and Hippuric Acid, m/z 178 for Negative Mode... [Pg.205]

A hot phosphate-buffered water extraction system (buffer, water at 90 °C or soxh-let with methanol) followed by subsequent Cjg-SPE coupled on-line to ESI-LC-MS was used for the analysis of monoHnuron, metabenzthiazuron, linuron and nebur-one in naturally aged agricultural soil. [546]. The comparison of ESI and APCI-LC-MS for the determination of diflubenzuron in fmits, proved that APCI was more efficient than ESI. The appHcation of positive-negative mode switching MS al-... [Pg.818]

Combination of assembled microcell [134] or Au chip electrode [132] with a positive-intrinsic-negative (PIN) photodiode detector lead to advancement in the miniaturization of ECL instrumentation for DNA quantification. Though, noise level and sensitivity of sihcon PIN diode are less sensitive than a PMT [134]. A highly sensitive DNA biosensor, fabricated by self-assembling the ECL probe of thiolated hairpin DNA tagged with ruthenium complex on the surface of a gold electrode works on a switch-off mode and ECL intensity decreases with an increase of the concentration of target DNA, and a detection limit of 9 x 10 M... [Pg.134]

In the context of safety applications, there are two generic types of limit switch, known as positive mode and negative mode switches. These are shown in Figure 13.4, which illustrates the switch s plunger being moved by a rotating cam. The positive mode switch is safer than the negative mode... [Pg.204]

Fig. 13.7 Positive and negative mode limit switches used in guard interlocking. Fig. 13.7 Positive and negative mode limit switches used in guard interlocking.
Compared to their internal ionization homologues, external ionization ion traps present the advantage of being less subject to contamination of the system by nonvolatile pollutants that mainly adsorb onto ion volume and ion extraction system. In terms of ionization, the external ionization ion trap does not allow switching from El to Cl in a few seconds but allows electron attachment if one wishes to work in negative mode. [Pg.63]

One of the specificities of ToF-SIMS is the possibility to switch easily from positive to negative ion mode by reversing the extraction potential. The mass calibration of spectra is internal, using low mass ions (H+, H2+, H3+, C+, CH+, CH2+ and CH3+ ion peaks in... [Pg.434]


See other pages where Switches negative mode is mentioned: [Pg.719]    [Pg.719]    [Pg.82]    [Pg.239]    [Pg.19]    [Pg.358]    [Pg.76]    [Pg.214]    [Pg.146]    [Pg.790]    [Pg.249]    [Pg.163]    [Pg.19]    [Pg.508]    [Pg.510]    [Pg.517]    [Pg.223]    [Pg.567]    [Pg.205]    [Pg.207]    [Pg.1467]    [Pg.487]    [Pg.66]    [Pg.308]    [Pg.66]    [Pg.308]    [Pg.740]    [Pg.189]    [Pg.1250]    [Pg.285]    [Pg.418]    [Pg.238]    [Pg.417]    [Pg.426]    [Pg.427]    [Pg.19]    [Pg.72]    [Pg.50]    [Pg.280]    [Pg.1250]    [Pg.361]    [Pg.137]    [Pg.666]    [Pg.678]   