Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sulfor oxides

Sulfor oxidizing bacteria oxidize sulfide and sulfite to sulfate. The decrease of oxygen [94,95] as well as the alteration of pH [96] can be used as indicators of these reactions. With a Thiobacillus thioparus-containing sensor, a detected limit of 4 pmol/1 sulfite is reached [94]. The detection limit of a sensor with Thiobacillus thiooxydans for sulfide is 0.02 mmol/1 only [95]. [Pg.103]

Schuck, E. A., and G. J. Doyle. Photooxidation of Hydrocarbons in Mixtures Containing Oxides of Nitrogen and Sulfor Dioxide. Report No. 29. San Marino, Calif. Air Pollution Foundation, 1959. 126 pp. [Pg.122]

Fire Hazards - Flash Point (deg. F) 252 OC Flammable limits in Air (%) Not pertinent Fire Extinguishing Agents Water Fire Extinguishing Agents Not To Be Used Not pertinent fecial Hazards of Combustion Products Toxic fumes include oxides of phosphorous, sulfor and hydrogen chloride Behavior in Fire Containers may nqtture Ignition Temperature (deg. F) 338 Electrical Hazard No data Burning Rate No data. [Pg.40]

Metabolic oxidation reactions may occur to the side chains of sulfor-containing residues, similar to that observed for in vitro chemical instability. Methionine can be oxidized to the sulfoxide, whereas metabolic oxidation of cysteine residues forms a disulfide. Metabolic reductive cleavage of disulfide bridges in proteins may occur, yielding free sulfhydryl groups. [Pg.223]

FIra extremely flemmable. keep away from open flame and sparks, no smoking avoid contoct with oxidants, sulforic acid and nitric add. powder. AFFF, foam, caibon dioxide, (halons). [Pg.509]

Covalent oxides react with water to give oxyacids these oxides are known as ACID anhydrides, as typified by sulfor trioxide, SO3,... [Pg.443]

The liquid from the centrifuge flows into a clarifier from which settled particles are returned to the crystallizer, and clarified liquor (containing 0.7 to 1.0% sulforic acid) is returned to the absorber/oxidizer circuit The flow rate of the return stream is approximately 500 gpm. A small amount of the dilute acid is continuously purged from the system to prevent build-up of chlorides that could cause corrosion of stainless steel equipment. A chloride limit of 200 ppm has been specifred for the plant Hie catalyst, iron sulfate, is not a major... [Pg.587]

Hazardous Decomp. Prods. CO, COj, corrosive/toxic oxides of sulfor HMIS Health 1, Flammability 1, Reactivity 0... [Pg.802]


See other pages where Sulfor oxides is mentioned: [Pg.122]    [Pg.340]    [Pg.340]    [Pg.193]    [Pg.360]    [Pg.276]    [Pg.317]    [Pg.1227]    [Pg.1630]    [Pg.1854]    [Pg.2479]   
See also in sourсe #XX -- [ Pg.454 , Pg.455 ]




SEARCH



Sulfor

© 2024 chempedia.info