Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Storage symbols

At both sites imbalances of the processed intermediate chemicals occur when all plants produce at full capacity. Unbalanced intermediate chemicals are indicated by a coloured storage symbol when inter-site transports are possible. Correspondingly coloured arrows between both sites indicate the direction of the product flow. Table 4-4 guantifies these imbalances and provides an overview on the chemicals associated storage capacities. [Pg.154]

Abstract automata are machines with internal states, an input tape, and sometimes an auxiliary information storage stack. Automata read symbols from the tape, making transitions from one state to another, while performing other operations on the tape and stack. The simplest example of such an idealized machine is the finite automaton ... [Pg.292]

Lines in vacuum service, 135—141 Line symbols, 17, 23 Numbering, 23 Lined centrifugal pumps, 171 Liquid-solid particle, separators, 228 Baffle type specifications, 248 Baffle type, 247, 248 Centrifugal, 256, 259-261 Chcvron-vanc, 248, 235 Comparison chart, 230 Cyclone, 259 Specification form, 268 Vane, 259 Wire mesh, 246 York-vane, 248 Low pressure storage... [Pg.628]

Figure 5.3-17. Flow-sheet of a batch process unit symbols E = heat exchanger, P = pump, R = reactor, T = storage tank, V = vessel controllers FC = flow controller, LC = level controller 0 stream number. Figure 5.3-17. Flow-sheet of a batch process unit symbols E = heat exchanger, P = pump, R = reactor, T = storage tank, V = vessel controllers FC = flow controller, LC = level controller 0 stream number.
As defined in Chapter Two, program schemes have basis function letters, predicate letters and constants, with "meanings" assigned by interpretations. These symbols plus the variables or storage locations are combined to form two basic kinds of instructions or statements, assignments and tests two special instructions,... [Pg.252]

Fig. 16.6 Reproducibility of the picture forming methods. Fruits from the same sample were analysed twice (before and after storage) and blind coded. The quality-interpretation in the form of a vitality index correlated significantly and well between the two analyses (R2 = 0.72 filled symbols = organic open symbols = conventional same symbol form = same village). Fig. 16.6 Reproducibility of the picture forming methods. Fruits from the same sample were analysed twice (before and after storage) and blind coded. The quality-interpretation in the form of a vitality index correlated significantly and well between the two analyses (R2 = 0.72 filled symbols = organic open symbols = conventional same symbol form = same village).
Figure 5.32 Plot of the storage and loss moduli for a PVA gel (symbols). The data has been curve fitted using two log normal distributions (see Section 4.4.5)... Figure 5.32 Plot of the storage and loss moduli for a PVA gel (symbols). The data has been curve fitted using two log normal distributions (see Section 4.4.5)...
Eigure 4.2. The E dependence of the storage G (solid symbols) and loss G" (open symbols) moduli of a mono-disperse silicon oil-in-water emulsion stabilized with SDS, with radius a = 0.53 jam, for three volume fractions from top to bottom (j> = 77%, 60%, and 57%. The frequency is 1 rad/s the lines are visual guides. (Adapted from [10].)... [Pg.130]

Rgure 4.4. The plateau storage modulus (small solid symbols) and the minimum of the loss modulus G (small open symbols) as a function of the effective oil volume fraction. a = 0.25 um (circles), a = 0.37 j,m (triangles), a = 0.53 um (squares), and a = 0.74 qm (diamonds). The large circles are the measured values for the osmotic pressure. All data are normalized by yint/a (Adapted from [10].)... [Pg.131]

Figure 12. G-BB storage stability—percent mass on backup section vs. time data points, average of two determinations (0,%) acetone, (A, A) trichloroethylene, ( J ) toluene open symbols, ambient temperature closed symbols, refrigerated... Figure 12. G-BB storage stability—percent mass on backup section vs. time data points, average of two determinations (0,%) acetone, (A, A) trichloroethylene, ( J ) toluene open symbols, ambient temperature closed symbols, refrigerated...
Storage stability was evaluated by storing photosensitive lithographic printing plates at 38°C and 80% relative humidity for 1 week and then evaluating development properties. These results are provided in Table 1, where the symbol A indicates excellent storage stability, and where storage stability deteriorates in order of the symbols B,... [Pg.596]

Figure 6.3 Fire division symbols for use on explosive buildings and stacks. Reprinted from DRDO s Storage and Transport of Explosives Committee (STEC) Pamphlet No.6, 1995 (As Amended). Figure 6.3 Fire division symbols for use on explosive buildings and stacks. Reprinted from DRDO s Storage and Transport of Explosives Committee (STEC) Pamphlet No.6, 1995 (As Amended).
Fig. 7 Storage (G ) and loss modulus (G") of phase-mixed TPVs plotted as a function of strain amplitude. Closed symbols represent the first run and open symbols the second measurement after relaxation and frequency sweep. PD2 TPV prepared by phase mixing... Fig. 7 Storage (G ) and loss modulus (G") of phase-mixed TPVs plotted as a function of strain amplitude. Closed symbols represent the first run and open symbols the second measurement after relaxation and frequency sweep. PD2 TPV prepared by phase mixing...
Fiq. 10 a, b. Effect of the comonomer volume fraction vH on (a) the relative height and (b) the relative storage modulus decrement of the low-temperature dispersion of 2-hydroxyethyl methacrylate (symbols as in Fig. 8)... [Pg.144]

We note that fzerotryl is a MATLAB function m file that is stored in its folder with the extension. m as fzerotryl.m. Our program code is annotated with comments following the % symbol. Anything that follows after a % symbol on a line of code is not executed in MATLAB. More on MATLAB files, their storage, creation, etc. is given in Section 1.2.5. Specific built-in MATLAB functions and their use, such as fzero in the code below, should always be scrutinized by our students for their input/output syntax etc. using the built-in help MATLAB command help fzero for example. [Pg.27]

Here s what those numbers and letters surrounded by the chasing-arrows symbol on the bottom of plastic bottles and other food storage containers mean. (If you can t find a number, call the manufacturer directly. On packaged food products, there is usually a toll-free question/comment number listed.) ... [Pg.105]

Fig. 2.68 Permittivity and loss tangent for Storage, loss modulus and loss tangent for ( )PDMI, (o) PDEI, (V) PDPI, (A) PDBI. The variation of tan S at lower temperatures for PDPI and PDBI is also shown at the bottom. Symbols are the same as those of the main figure. (From ref. [238])... Fig. 2.68 Permittivity and loss tangent for Storage, loss modulus and loss tangent for ( )PDMI, (o) PDEI, (V) PDPI, (A) PDBI. The variation of tan S at lower temperatures for PDPI and PDBI is also shown at the bottom. Symbols are the same as those of the main figure. (From ref. [238])...

See other pages where Storage symbols is mentioned: [Pg.175]    [Pg.163]    [Pg.398]    [Pg.527]    [Pg.569]    [Pg.9]    [Pg.387]    [Pg.326]    [Pg.432]    [Pg.42]    [Pg.66]    [Pg.72]    [Pg.80]    [Pg.80]    [Pg.112]    [Pg.178]    [Pg.292]    [Pg.183]    [Pg.184]    [Pg.114]    [Pg.261]    [Pg.12]    [Pg.220]    [Pg.11]    [Pg.170]    [Pg.202]    [Pg.290]    [Pg.1366]    [Pg.150]    [Pg.163]    [Pg.539]   
See also in sourсe #XX -- [ Pg.175 ]




SEARCH



© 2024 chempedia.info