Steady-state absorption technique

Phosphorescence, Fluorescence and Steady-state Absorption Techniques... [Pg.429]

Steady-State Spectral Convolution. The steady state absorption and emission spectra of dilute dye samples can be measured using standard spectroscopic techniques. Once the extinction coefficient, e( ), and the normalized luminescence spectrum, f(v), are known for a particular dye, the self—absorption probability r over a pathlength L in the sample containing the dye at a concentration C is given by... [Pg.339]

The detection limits in the table correspond generally to the concentration of an element required to give a net signal equal to three times the standard deviation of the noise (background) in accordance with lUPAC recommendations. Detection limits can be confusing when steady-state techniques such as flame atomic emission or absorption, and plasma atomic emission or fluorescence, which... [Pg.717]

The first intermediate to be generated from a conjugated system by electron transfer is the radical-cation by oxidation or the radical-anion by reduction. Spectroscopic techniques have been extensively employed to demonstrate the existance of these often short-lived intermediates. The life-times of these intermediates are longer in aprotic solvents and in the absence of nucleophiles and electrophiles. Electron spin resonance spectroscopy is useful for characterization of the free electron distribution in the radical-ion [53]. The electrochemical cell is placed within the resonance cavity of an esr spectrometer. This cell must be thin in order to decrease the loss of power due to absorption by the solvent and electrolyte. A steady state concentration of the radical-ion species is generated by application of a suitable working electrode potential so that this unpaired electron species can be characterised. The properties of radical-ions derived from different classes of conjugated substrates are discussed in appropriate chapters. [Pg.21]

The opportunistic measurement techniques generally used are absorption and Rn disequilibrium (Asher and Wanninkhofi 1998). First, there is an estimate of a long-term ( 1,000 years) global gas transfer coefficient of = 6 x 10 m/s, developed by assuming steady state between pre-1950 radioactive decay in the oceans and absorption from the atmosphere (Broecker and Peng, 1982). In addition, nuclear testing since 1950 has increased concentration in the atmosphere. Thanks... [Pg.247]

To study the excited state one may use transient absorption or time-resolved fluorescence techniques. In both cases, DNA poses many problems. Its steady-state spectra are situated in the near ultraviolet spectral region which is not easily accessible by standard spectroscopic methods. Moreover, DNA and its constituents are characterised by extremely low fluorescence quantum yields (<10 4) which renders fluorescence studies particularly difficult. Based on steady-state measurements, it was estimated that the excited state lifetimes of the monomeric constituents are very short, about a picosecond [1]. Indeed, such an ultrafast deactivation of their excited states may reduce their reactivity something which has been referred to as a "natural protection against photodamage. To what extent the situation is the same for the polymeric DNA molecule is not clear, but longer excited state lifetimes on the nanosecond time scale, possibly of excimer like origin, have been reported [2-4],... [Pg.471]

Time-resolved Photoacoustic Spectroscopy. In photoacoustic spectroscopy (PAS) the heat evolved by the absorption of light in the sample is transformed into sound waves which are detected by a microphone. In steady-state spectroscopy the light is continuous, but it is also possible to use a pulsed laser and to observe the change in the intensity of the sound signal with time. In this respect time-resolved PAS is somewhat similar to thermal lensing, but both techniques have different limitations and advantages. [Pg.252]

There have been very few studies on the kinetics of micellization in block copolymer solutions. Micellization in aqueous surfactant systems close to equilibrium occurs on a time-scale far below one second. Experimental results obtained by fast reaction techniques, such as temperature jumps or pressure jumps or steady-state methods such as ultrasonic absorption, NMR and ESR, show that at least... [Pg.197]

An interesting development in molecular rotational relaxation has been the microwave double-resonance method176-178. The technique permits the exploration of the fine detail of the processes which occur in collisions of polyatomic molecules, and results for a number of symmetric tops have been reported. For example, Oka has described experiments on NH3 in which inversion doublets for selected J values were pumped by high microwave power. Pumping disturbs the population of the inversion doublet, and also that of other doublets which are populated from the original pair by collision processes. By absorption measurements of other inversion doublets with steady state irradiation, Oka has shown that in NH3/NH3 collisions, transitions which are allowed by the electric dipole selection rules (A/ = 0, 1, + - —) are preferred. Oka s analysis indicates that relaxation is most favourable in collision with molecules having similar J values, which are termed rotational resonances (R-R transfer). For example the process... [Pg.235]


See other pages where Steady-state absorption technique is mentioned: [Pg.195]    [Pg.220]    [Pg.113]    [Pg.164]    [Pg.865]    [Pg.865]    [Pg.211]    [Pg.339]    [Pg.136]    [Pg.865]    [Pg.388]    [Pg.1207]    [Pg.2]    [Pg.198]    [Pg.264]    [Pg.1375]    [Pg.230]    [Pg.378]    [Pg.87]    [Pg.95]    [Pg.168]    [Pg.151]    [Pg.124]    [Pg.164]    [Pg.72]    [Pg.50]    [Pg.59]    [Pg.196]    [Pg.55]    [Pg.532]    [Pg.430]    [Pg.63]    [Pg.111]    [Pg.490]    [Pg.123]    [Pg.361]    [Pg.120]    [Pg.212]   