Solenoid valves characteristics

The injector, when used directly, was not suitable for ACC at high frequencies as it produced very large droplets. To reduce droplet size, a swirl-based atomizer with 300 pm exit diameter [29] was fitted at the fuel jet exit. In this close-coupled configuration, the automotive fuel injector was used as a high-frequency solenoid valve for the fuel line. This new combination actuator improved the overall atomization characteristics while maintaining good frequency... [Pg.335]

Trapezoidal characteristics, e.g. of an output for solenoid valves may result in two different Ex i-specifications for a single pair of terminals ... [Pg.391]

Fig. 15.24a. A portion of the gas from the atmosphere or an industrial chimney is sucked by a pump and passed through a filter with a pore size ensuring retention of unwanted particles —this is the sampling step, which may include the measurement of the moisture in the collected gas. In the measuring stage, the sample is passed through a solenoid valve, a pressure gauge and the IR analyser, which measures the absorption of both analytes at their characteristic wavelengths. The data generated and the sample pressure are acquired by recorders and/or a computer which allows the determination of the atmospheric concentration of both analytes. The solenoid valve allows the arrival of CO and CO2 standards at the detector to run the pertinent calibrations. Fig. 15.24a. A portion of the gas from the atmosphere or an industrial chimney is sucked by a pump and passed through a filter with a pore size ensuring retention of unwanted particles —this is the sampling step, which may include the measurement of the moisture in the collected gas. In the measuring stage, the sample is passed through a solenoid valve, a pressure gauge and the IR analyser, which measures the absorption of both analytes at their characteristic wavelengths. The data generated and the sample pressure are acquired by recorders and/or a computer which allows the determination of the atmospheric concentration of both analytes. The solenoid valve allows the arrival of CO and CO2 standards at the detector to run the pertinent calibrations.
This conhguration is called intermeshed . It has superior characteristics. If, however, events of encompassing impacts like hres are included in the analysis, the separated conhguration might prove superior. It permits a more efficient spatial segregation of the redundant chains (switch-solenoid-valve-shut-off valve) and would thus reduce the probability of a hre to affect the redundancies at the same time. [Pg.371]

If one of the solenoid valves has the mechanical failure, TCU will not find the failure. At this time, the failure operation of transmission will be determined according to the solenoid valve with failure. The characteristic of different solenoid valve failure is listed in Table 6.1.2. [Pg.123]

There are several different devices for determination of dust explosion characteristics. All devices include a vessel which may be op>en or closed, an ignition source which may be an electrical spark or electrically heated wire coil and a supply of air for dispersion of the dust. The simplest apparatus is known as the vertical tube apparatus and is shown schematically in Figure 15.4. The sample dust is placed in the dispersion cup. Delivery of dispersion air to the cup is via a solenoid valve. Ignition may be either by electrical spark across electrodes or by heated coil. The vertical tube apparatus is used for the classification test and for determination of minimum dust concentration for explosion, minimum energy for ignition and in a modified form for minimum oxygen for combustion. [Pg.380]

The technical specification of each cylinder depends on the duty and characteristics of each unit, since the precise operation and timing of the movement of the cylinders are very important for safe and automatic operations. Any deviation or delay could stop the operation or damage the irradiated sample inside the system. Therefore, some of these cylinders are operated at different air pressures (two and four bars) or special adapters control their movements. Valves with flow rates of 400 1/min are used to operate the cylinders while the movement of samples inside the system requires solenoid valves, with flow rates ranging between 1300-3400 1/min. The operation time of each valve is controlled by software. Most of the pneumatic devices and valves are arranged and installed inside two cabinets (Figure If). [Pg.124]

There are plenty of alternatives available for pressure equalization, but the challenge is to come up with the least costly alternative that will do the job adequately and safely. A particular valve may have some characteristics that you need, but may be missing other necessary characteristics. For instance, it is easy to find electronic/solenoid systems for handling pressure and flow, but then the component must also work with hydrogen and oxygen and potassium hydroxide. The possibilities begin to narrow and the prices rise sharply. [Pg.204]

Control modules are the lowest grouping of equipment eapahle of carrying out basic control. For example, solenoids and limit switches combined can form 01J70n valve control modules, and transmitters and valves can be combined into PID control modules. The main characteristics of the control modules is a) the direct connection to the process, and b) these modules cannot execute any procedural elements. [Pg.507]

This operating characteristic of solenoid acmators is important. For example, a normally closed valve that uses a solenoid actuation can only be open when the solenoid is energized. As soon as the electrical energy is removed from the solenoid s coil, the valve returns to the closed position. The reverse is true of a normally open valve. The main valve remains open, except when the solenoid is energized. [Pg.199]


See other pages where Solenoid valves characteristics is mentioned: [Pg.67]    [Pg.423]    [Pg.220]    [Pg.524]    [Pg.1294]    [Pg.285]    [Pg.214]    [Pg.324]    [Pg.184]    [Pg.778]    [Pg.1155]   