Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Small component normalization factor

Polyurethane wheels may be small components in a piece of machinery or a large part of drive wheels on items such as forklifts or rod mills. Speed is the normal limiting factor in the use of polyurethane wheels. This is a result of heat buildup. Special polyurethanes find an application as spare motor car wheels. [Pg.270]

The equipment for continuous distillation can only separate one stage in the equilibrium diagram. Countercurrent distillation, also called rectification, has found widespread application with normal pressure and coarse vacuum distillation when complex mixtures or components with small relative volatility factor are to be separated. The fundamentals are discussed above (2.1.3.3.2) the technical side will be dealt with here [41-45]. [Pg.90]

These functions satisfy the normalization condition (20). It should be noted that the ratio of the scale factors in (48) and (49) is - (1 — e /c )/ I + Cmc/c ) 0iZl2n. Thus, Qnit r) is several orders of magnitude smaller than Pn ( ) for Z = 1. For this reason, P K and QnK are referred to as the large and small components of the radial Dirac wave function, respectively. [Pg.127]

In this form the 2pi/2 does appear better behaved. The large component adds in another power of r in the lowest order, and yields the correct power dependence for a nonrela-tivistic 2p function. The problem of the singularity persists in the lowest order for the small component, but here the normalization factor Mq vanishes in the nonrelativistic limit, and so the small component also tends towards the correct behavior. As discussed in chapter 4, this is not true at r = 0, where the singularity persists. [Pg.110]

Let H and L be two characteristic lengths associated with the channel height and the lateral dimensions of the flow domain, respectively. To obtain a uniformly valid approximation for the flow equations, in the limit of small channel thickness, the ratio of characteristic height to lateral dimensions is defined as e = (H/L) 0. Coordinate scale factors h, as well as dynamic variables are represented by a power series in e. It is expected that the scale factor h-, in the direction normal to the layer, is 0(e) while hi and /12, are 0(L). It is also anticipated that the leading terms in the expansion of h, are independent of the coordinate x. Similai ly, the physical velocity components, vi and V2, ai e 0(11), whei e U is a characteristic layer wise velocity, while V3, the component perpendicular to the layer, is 0(eU). Therefore we have... [Pg.178]

Typical NP conditions involve mixtures of n-hexane or -heptane with alcohols (EtOH and 2-propanol). In many cases, the addition of small amounts (<0.1%) of acid and/or base is necessary to improve peak efficiency and selectivity. Usually, the concentration of alcohols tunes the retention and selectivity the highest values are reached when the mobile phase consists mainly of the nonpolar component (i.e., n-hexane). Consequently, optimization in NP mode simply consists of finding the ratio n-hexane/alcohol that gives an adequate separation with the shortest possible analysis time [30]. Normally, 20% EtOH gives a reasonable retention factor for most analytes on vancomycin and TE CSPs, while 40% is more appropriate for ristocetin A-based CSPs. Ethanol normally gives the best efficiency and resolution with reasonable backpressures. Other combinations of organic solvents (ACN, dioxane, methyl tert-butyl ether) have successfully been used in the separation of chiral sulfoxides on five differenf glycopepfide CSPs, namely, ristocetin A, teicoplanin, TAG, vancomycin, and VAG CSPs [46]. [Pg.133]

Detector sensitivity is one of the most important properties of the detector. The problem is to distinguish between the actual component and artifact caused by the pressure fluctuation, bubble, compositional fluctuation, etc. If the peaks are fairly large, one has no problem in distinguishing them however, the smaller the peaks, the more important that the baseline be smooth, free of noise and drift. Baseline noise is the short time variation of the baseline from a straight line. Noise is normally measured "peak-to-peak" i.e., the distance from the top of one such small peak to the bottom of the next. Noise is the factor which limits detector sensitivity. In trace analysis, the operator must be able to distinguish between noise spikes and component peaks. For qualitative purposes, signal/noise ratio is limited by 3. For quantitative purposes, signal/noise ratio should be at least 10. This ensures correct quantification of the trace amounts with less than 2% variance. The baseline should deviate as little as possible from a horizontal line. It is usually measured for a specified time, e.g., 1/2 hour or one hour and called drift. Drift usually associated to the detector heat-up in the first hour after power-on. [Pg.11]

The actual power loss in a dielectric in an AC field is proportional to the loss factor, i.e. the product of permittivity and power factor, so that to achieve the minimum loss both of these parameters must be small. Power loss is also proportional to frequency so that at high frequencies, for example in telecommunications applications, it may be especially necessary to use low permittivity and low loss materials. For making capacitors, a high permittivity is desirable because then the physical size of the component for a given capacitance can be as small as possible. A high loss is not normally wanted in a capacitor so that the ideal dielectric would have a high permittivity and a low power factor. A high loss factor may be desirable... [Pg.271]

Absorption and fluorescence spectra of aromatic hydrocarbons are not greatly affected by change of solvent, except for small solvent shifts. At low temperatures the vibrational structure of the bands sharpens up, and some peculiar solvent effects have been noted. When frozen in solution of normal paraffins coronene shows doubling of some of its vibrational bands, and the separation of the components varies with the number of carbon atoms in the solvent molecule chain. The most probable cause is some size-relationship factor between solvent and solute molecules (7). [Pg.29]

In the case of purity analysis or the measurement of major components, the traceability steps and associated uncertainties illustrated in Fig. 3 can be expected. In these cases, a small uncertainty is normally required and a variety of factors can contribute significantly to it, including mass, volume, and other physical as well as chemical effects. Thus in these cases, both Ur and Uc may be significant. [Pg.90]


See other pages where Small component normalization factor is mentioned: [Pg.18]    [Pg.298]    [Pg.441]    [Pg.109]    [Pg.124]    [Pg.1335]    [Pg.860]    [Pg.196]    [Pg.628]    [Pg.555]    [Pg.35]    [Pg.1512]    [Pg.196]    [Pg.8]    [Pg.101]    [Pg.36]    [Pg.199]    [Pg.146]    [Pg.309]    [Pg.243]    [Pg.167]    [Pg.123]    [Pg.124]    [Pg.295]    [Pg.274]    [Pg.219]    [Pg.642]    [Pg.371]    [Pg.228]    [Pg.590]    [Pg.152]    [Pg.63]    [Pg.197]    [Pg.173]    [Pg.99]    [Pg.68]    [Pg.813]    [Pg.339]    [Pg.597]    [Pg.28]   
See also in sourсe #XX -- [ Pg.109 ]




SEARCH



Component factor

Factor normalized

Factor normalizing

Normal component

Normalization factor

© 2024 chempedia.info