Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensor configuration

A Nemstian response of 59 mV per decade change in concentration is commonly observed (at 25°C). Relation to the partial pressure carbon dioxide is accomplished by the use of Henry s law. A catheter sensor configuration has been developed for in-vivo monitoring of blood carbon dioxide (61). [Pg.189]

A sensor configuration employing these cones is shown in Figure 15 Fluorescence from the luminescent spots is excited from behind the platform using an appropriate source (LED s in this case), is subsequently emitted via total internal reflection through the sensor chip and is detected by a CMOS camera, which is positioned behind the chip. For the purposes of intensity comparisons, luminescent spots are also deposited directly onto the planar surface of the chip and excited along with those deposited on the cones. [Pg.207]

For leak detection, the sensor must be sensitive and fast enough to provide early leak detection so that action can be taken before the explosive limit in air is reached. Utilizing a fiber-optic sensor configuration could provide the best chance of meeting fast response and inexpensive and reliable goals. [Pg.366]

Fig. 20a.2. Optical sensor configurations (a) intrinsic sensors, (b) mediator assistant chemical sensor, and (c) chemical sensor-based biosensor. Fig. 20a.2. Optical sensor configurations (a) intrinsic sensors, (b) mediator assistant chemical sensor, and (c) chemical sensor-based biosensor.
Figure 5. SPR sensor based on ATR method and angular modulations (upper) and corresponding reflectivity calculated for two different refractive indices of sample (lower). Sensor configuration SF14 glass prism, 50 nm thick gold layer, sample, wavelength - 682 nm. Figure 5. SPR sensor based on ATR method and angular modulations (upper) and corresponding reflectivity calculated for two different refractive indices of sample (lower). Sensor configuration SF14 glass prism, 50 nm thick gold layer, sample, wavelength - 682 nm.
Figure 3.21 Alternative PAT sensor configuration/deployment in bypass loop configuration. Note that the field of view is here equal to the full stream cross section. Various combinations of the principles illustrated in Figures 3.20 and 3.21 offers convenient process technology flexibility to deal with just about any conceivable scenario otherwise threatened by the traditional fatal IDE/IEE issues illustrated in this chapter. Figure 3.21 Alternative PAT sensor configuration/deployment in bypass loop configuration. Note that the field of view is here equal to the full stream cross section. Various combinations of the principles illustrated in Figures 3.20 and 3.21 offers convenient process technology flexibility to deal with just about any conceivable scenario otherwise threatened by the traditional fatal IDE/IEE issues illustrated in this chapter.
We further addressed the use of the nucleic acids as biopolymers for the formation of supramolecular structures that enable the electronic or electrochemical detection of DNA. Specifically, we discussed the use of aptamer/low-molecular-weight molecules or aptamer/protein supramolecular complexes for the electrical analysis of the guest substrates in these complexes. Also, nucleic acid-NPs hybrid systems hold a great promise as sensing matrices for the electrical detection of DNA in composite three-dimensional assemblies. While sensitive and selective electrochemical sensors for DNA were fabricated, the integration of these sensor configurations in array formats (DNA chips) for the multiplexed analysis of many DNAs can also be envisaged. [Pg.372]

The mechanisms of detection and the functions of the conductor layer and of the semiconductor are the same in a C-I-S diode sensor as they are in a C-S diode sensor. The only difference between these two structures is the presence of the purposefully inserted interfacial layer (I-layer) between the conductor and the semiconductor in the C-I-S devices. In general, this I-layer is employed in the C-I-S sensor configuration for one of two reasons (1) either it is used to block chemical reactions between the conductor and the semiconductor or (2) it is used to augment or reduce the role of the interface in establishing the double layer or controlling transport. [Pg.181]

Another problem is waste generation. Since, after detection, the solution has a pH of 11.5-13, it cannot, depending on the application, be sent back to the bath where the process occurs at a lower pH. This means that the waste quantity created by the system must be kept as low as possible and that one should miniaturise the sensor configuration as much as is practicable. According to a limited survey realised with the users of hydrogen peroxide, a waste volume of 11/h is considered as acceptable. Finally, a dilution factor should be taken into account, which depends on the volumes of both liquid flows mixed in the injection area of the FIA system. [Pg.154]

The instrumentation consisted of the hand-held potentiostat interfaced with a CH8 multiplexer (PalmSens) (Fig. 29.3) that allow different sensor configuration ... [Pg.700]

Fig. 40.1. Sensor configuration (45 x 4.0 mm). (1) Substrate, (2) platinum paste layer, (3) insulator and (4) working area (7.5 mm2). Fig. 40.1. Sensor configuration (45 x 4.0 mm). (1) Substrate, (2) platinum paste layer, (3) insulator and (4) working area (7.5 mm2).
Table 1 Near-IR chromoionophores applied in bulk optodes. The absorption maxima, the type of matrix employed, the sensor configuration, the optical properties measured, the analyte and year of publication are listed... [Pg.10]

Several complexities must be addressed in order to fully understand the mode(s) of binding and the effects of the linker and dye on the stability of the duplex. The fact that the greatest stability was observed with an alkyl chain linker may be somewhat problematic in a dirty sample, as might be encountered in the analysis of crudely prepared real-world samples. In such cases, the alkyl chain could provide sites at which proteins and lipids might adsorb. Quantum yields are sufficient such that polyethylene glycol tethers could be used in real-world sensor configurations. [Pg.247]

Ionic strength influences are well known with respect to the rate and energetics of nucleic acid hybridization [17]. Charge and ionic radius are both important in terms of stabilizing the structure of the duplex as well as stabilizing the stem portion of the molecular beacon [17]. The stem structure stability was increased when a divalent cation was incorporated into the hybridization buffer solution [17]. It was reported that cations were best at stabilizing the duplex formed upon hybridization in the order Ca2+ > Mg2+ K+ > Na+. The ultimate detection limit of the sensor configuration was calculated to be 1.1 nM [17]. [Pg.253]

Fig. 6 a General waveguide sensor configuration b typical sensorgram... [Pg.284]

Figure 7 Three-dimensional ECVT sensor configuration and electrical potential distribution (Warsito and Fan, 2005) (see Plate 10 in Color Plate Section at the end of this book). Figure 7 Three-dimensional ECVT sensor configuration and electrical potential distribution (Warsito and Fan, 2005) (see Plate 10 in Color Plate Section at the end of this book).

See other pages where Sensor configuration is mentioned: [Pg.1313]    [Pg.374]    [Pg.210]    [Pg.213]    [Pg.365]    [Pg.512]    [Pg.260]    [Pg.326]    [Pg.328]    [Pg.137]    [Pg.137]    [Pg.139]    [Pg.141]    [Pg.68]    [Pg.135]    [Pg.311]    [Pg.17]    [Pg.144]    [Pg.182]    [Pg.145]    [Pg.116]    [Pg.9]    [Pg.13]    [Pg.251]    [Pg.254]    [Pg.260]    [Pg.274]    [Pg.354]    [Pg.357]    [Pg.584]    [Pg.62]   
See also in sourсe #XX -- [ Pg.26 , Pg.27 ]




SEARCH



Sensors Sensor configuration

© 2024 chempedia.info