Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Semi nozzle

Thermal Relief Semi Nozzle Full Nozzle Snap Acting Proportional High Performance Metal Seated Sort Seated Steam Valve Liquid Valve Gas Valve conventional Valve Balanced Bellow... [Pg.34]

In case of a semi-nozzle design, the body flange is in contact with the mating flange and the fluid is in permanent contact with the valve body. [Pg.107]

Castings have cavities in which particles can be FIGURE 5.20 trapped (see above). Full and semi-nozzle design... [Pg.107]

Conversely, the semi-nozzle design consists of a seating ring fitted into the body bowl. The top of the nozzle forms the seat of the valve. The advantage... [Pg.108]

The operating principle is similar to that of API valves with the exception that the blowdown ring and resulting adjustable huddling chamber are usually semi-nozzle design (Figure 5.47). [Pg.136]

Both full and semi-nozzles, bodies for seminozzle valves, bodies with integral nozzles, primary pressure-containing components of pilot-operated main valve... [Pg.275]

Make a preliminary mechanical design for the vertical thermosyphon reboiler for which the thermal design was done as Example 12.9 in Chapter 12. The inlet liquid nozzle and the steam connections will be 50 mm inside diameter. Flat plate end closures will be used on both headers. The reboiler will be hung from four bracket supports, positioned 0.5 m down from the top tube plate. The shell and tubes will be of semi-killed carbon steel. [Pg.890]

The experiments were carried out on a semi-industrial fluidized bed reactor, illustrated in Figure 9.6, which shows four different sensor positions (A, B, C and D). Screw fittings were used to mount the sensors in order to secure optimal sensor pickup efficiency. Sensor location A is mounted onto an orifice plate on the main supply line of liquid urea to the reactor nozzles, following Esbensen et al. [5]. The sensors B, C and D are located on the wall of reactor chambers 1, 2 and 4, respectively. [Pg.286]

The formula for semi-ideal gas flow through a nozzle is commonly used to obtain the flow capacity of a safety valve14 -... [Pg.192]

Fig. 17.11 Extinction behavior of strained, opposed-flow, premixed, methane-air flames. The left-hand panel shows the dependence of the maximum temperature at the symmetry plane as a function of the semi-infinite strain-rate parameter a, for five different mixture stoichiometries. The right-hand panel compares measured extinction strain rates [238] with predictions for both the semi-infinite and finite-gap model formulations. The nozzle separation distance is 7 mm (i.e., 3.5 mm from nozzle to symmetry plane). Fig. 17.11 Extinction behavior of strained, opposed-flow, premixed, methane-air flames. The left-hand panel shows the dependence of the maximum temperature at the symmetry plane as a function of the semi-infinite strain-rate parameter a, for five different mixture stoichiometries. The right-hand panel compares measured extinction strain rates [238] with predictions for both the semi-infinite and finite-gap model formulations. The nozzle separation distance is 7 mm (i.e., 3.5 mm from nozzle to symmetry plane).
CHARDONNET, H. (1839-1924). A native of France, he has been called the lather of rayon because of his successful research in producing what was then called artificial silk from nitrocellulose. He was able in extrude fine threads of this semi-synthetic material through a spinnetetle-like nozzle, and Ihe textile product was made on a commercial scale in several European countries. He was awarded Ihe Perkin medal for his work... [Pg.321]

The main valve is basically a simple valve body design with a free-moving piston on a nozzle (semi or full). The main valve represents the capacity of the valve and is designed to flow the required rated flow. The pilot represents the quality of the valve and makes sure the valve works conectly. A pilot is usually the same for all sizes and pressures for a certain range of pilot-operated valves and is relatively small. The pilot is the intelligence of the valve and is where the set pressure is adjusted. [Pg.125]

Modulating pilot valves shall be exclusively used for two-phase flow conditions. All pilot-operated valves shall be equipped with on-site test connections and equipped with a supply filter with minimum 60 pm element. Pilot-operated valves can be of semi- or full nozzle design. [Pg.274]

Nozzle Type Full [ ] Semi [ ] 19. Scat (Nozzle) Disk ... [Pg.307]

Figure 7.6 Semi-quantitative analysis of an organic two-component coating on a metal surface. The classifier grades the results into within specification (light grey), warning (white), mixing ratio/coverage outside specification (dark grey) and surface defects on the metal carrier (black). A significant isolated problem, B localised constant problem, C acceptable localised random flaws, E start of massive failure, F localised application of primarily one component only due to spray nozzle obstruction. Figure 7.6 Semi-quantitative analysis of an organic two-component coating on a metal surface. The classifier grades the results into within specification (light grey), warning (white), mixing ratio/coverage outside specification (dark grey) and surface defects on the metal carrier (black). A significant isolated problem, B localised constant problem, C acceptable localised random flaws, E start of massive failure, F localised application of primarily one component only due to spray nozzle obstruction.
Scheme 2. Affinity chromatography bioreactor (ACBR) for the semi-continuous recovery of plant-produced proteins. Media is drawn up through the intake nozzle (D) during culture, through a pre-filter (B) that removes particulates, and then to a protein-collection column (C) using a peristaltic pump. After protein binding, the media is returned to the growth chamber. Humidified air is supplied to the culture through a sterile pre-filter (A) [62]... Scheme 2. Affinity chromatography bioreactor (ACBR) for the semi-continuous recovery of plant-produced proteins. Media is drawn up through the intake nozzle (D) during culture, through a pre-filter (B) that removes particulates, and then to a protein-collection column (C) using a peristaltic pump. After protein binding, the media is returned to the growth chamber. Humidified air is supplied to the culture through a sterile pre-filter (A) [62]...
To determine the dominant frequency of excitation, the near-field acoustic spectrum was obtained using a microphone. Typical near-field acoustic spectra for an excited jet and a natural jet are shown and compared in Fig. 29.5. When multiple peaks were observed in the spectrum, the peak with the highest spectral amplitude was denoted as the excitation frequency. By systematically varying the dimensions of the cavity, flow excitation occurred over a wide range of frequencies (4-40 kHz). Table 29.2 summarizes the normalized data. Initial tests were performed with semi-annular cavities to eliminate possible pressure mismatching associated with flow ejection effect in fully annular cavities. The semi-annular cavities in this case were flush mounted at the nozzle exit (x = L) to simplify the acoustic analysis. [Pg.501]

Several other types of hand-held vacuum samplers have been used to collect dust from residential surfaces. One of these, the Baltimore Repair and Maintenance Study Cyclone Sampler (BRMCS) (Farfel et al 1994), has been evaluated against the HVFS. The BRMCS uses the same cyclone and catch bottle assembly as the HVS3, but a different nozzle and vacuum source. The vacuumed dust is sucked into the cyclone via a semi-rigid Tygon hose (2.54-cm o.d.) that is notched on the sampling end to simulate a nozzle. Suction is provided by a small, hand-held vacuum device (Royal Hand Vac , Model 553, 2 A). The collection efficiency for the BRMCS was determined to be 44.1 % n =6, s = 3.8) for plush uylou carpet, 61.1 % (n = 6, = 6.7) for level loop carpeting, 71.8-87.8 % n =6, s = 3.5) for upholstery and 84.7 % n = 3, s = 2.3) for wood surfaces (USEPA, 1996b). [Pg.101]

There are many different spray guns available and the type used does not seem to be critical , but the small type known as an artist s air brush is suitable for small components, and standard paint spray guns for larger components. The operator should standardise on one type of gun and nozzle for the sake of consistency. Where a large number of similar components are to be sprayed it is desirable to set up a semi-automatic or automatic system to ensure uniformity. [Pg.194]

When the. gases strike the first baffle-plate after having left -the nozzle 62, they 60 are in a semi-dispersed state, that is, they have followed to some extent the lines of the nozzle, although there is probably still a column of concentrated gas directly behind the bullet. The eflect of stiiking the 85 first baffie-jdate is that most of the gas is... [Pg.90]


See other pages where Semi nozzle is mentioned: [Pg.52]    [Pg.109]    [Pg.109]    [Pg.52]    [Pg.109]    [Pg.109]    [Pg.266]    [Pg.504]    [Pg.450]    [Pg.372]    [Pg.916]    [Pg.1049]    [Pg.326]    [Pg.337]    [Pg.525]    [Pg.290]    [Pg.286]    [Pg.474]    [Pg.459]    [Pg.468]    [Pg.704]    [Pg.53]    [Pg.309]    [Pg.67]    [Pg.622]    [Pg.504]    [Pg.380]    [Pg.458]    [Pg.1735]    [Pg.313]   
See also in sourсe #XX -- [ Pg.41 , Pg.95 , Pg.96 ]




SEARCH



Nozzle

Nozzle, nozzles

© 2024 chempedia.info