Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scan shift

From these curves, it can be inferred that the peak potential of the cathodic scan shifts toward more cathodic values as K increases (Keq decreases), since the electrochemical reaction becomes more difficult. Another feature of the voltammograms is that they shift toward more negative potentials when increases, the more so the larger K, since //2 V( /o/f/j also increases. [Pg.403]

Reading requires the eye(s) to focus, not moving, on a particular aspect of the field to be read. The eye is seldom motionless, and usually is involved in rapid scanning shifts called saccades. Visual efficiency is a composite of a number of factors once attention has been focused these include legibility, print size, use of color, length of word or sentence, spacing, type style, level of illumination and visual acuity. [Pg.19]

HORIZONTAL SCAN SHIFT REGISTER AND SWITCHING DRIVER... [Pg.463]

Does the vendor require that during scan-shift all the outputs have no switching, all ouq>uts are three-state outputs. [Pg.212]

Bi-directionals are also treated as three-state nets by TC. Hence, the insertion of disabling logic would occur for bi-directionals unless the -no disable option is used. Bidirectional ports, by default, are always configured in the output mode during test. There are options available with the set scan configuration command to specify the direction of the bi-directional ports during scan shift. [Pg.220]

The default test protocol inferred by TC has four phases Scan Shift, Parallel Measure, Parallel Capture, and Scan-Out Strobe. Each test pattern has all these phases. The length of the scan shift phase is equal to the length of the longest scan chain in the design. The remaining three phases are of one cycle with the test clock being pulsed in only during scan shift and the parallel capture cycle. Shown below are the values of the bi-directionals in the different phases ... [Pg.222]

Clock skew in the scan path could result in a scan pull-through or a diverging scan chain. In other words, during the scan shift phase, due to clock skew the same scan bit can be loaded into two successive scan cells. [Pg.224]

Eveiy test pattern consists of the following phases scan-shift, parallel measure, parallel capture, and scan-out strobe. You can add initialization vectors at the start of the test program using the read init protocol command. Shown below is the default protocol inferred by TC for a design after scan-insertion. [Pg.230]

After formatting the vectors generated from ATPG, you observe that in the patterns, TC does not strobe the scan-out during scan-shift in some patterns, for one scan cell. Shown below is a segment of the formatted Verilog vectors which shows that the scan-out strobe is missing at time 3955. [Pg.235]

In the default test protocol inferred by TC, the last scan cell in the scan chain is strobed in the scan-out strobe cycle after the parallel capture cycle. If this is not the case, the next scan-shift cycle will overwrite the captured response in the last scan cell before it is strobed. Hence in the last cycle of the scan shift there is no expected response, that is an X. [Pg.242]

Selectivity Selectivity in voltammetry is determined by the difference between half-wave potentials or peak potentials, with minimum differences of+0.2-0.3 V required for a linear potential scan, and +0.04-0.05 V for differential pulse voltammetry. Selectivity can be improved by adjusting solution conditions. As we have seen, the presence of a complexing ligand can substantially shift the potential at which an analyte is oxidized or reduced. Other solution parameters, such as pH, also can be used to improve selectivity. [Pg.531]

Figure 2.11. Proton-Proton shift correlations of a-pinene (1) [purity 99 %, CDCls, 5 % v/v, 25 °C, 500 MHz, 8 scans, 256 experiments], (a) HH COSY (b) HH TOCSY (c) selective one-dimensional HH TOCSY, soft pulse irradiation at Sh = 5.20 (signal not shown), compared with the NMR spectrum on top deviations of chemical shifts from those in other experiments (Fig. 2.14, 2.16) arise from solvent effects... Figure 2.11. Proton-Proton shift correlations of a-pinene (1) [purity 99 %, CDCls, 5 % v/v, 25 °C, 500 MHz, 8 scans, 256 experiments], (a) HH COSY (b) HH TOCSY (c) selective one-dimensional HH TOCSY, soft pulse irradiation at Sh = 5.20 (signal not shown), compared with the NMR spectrum on top deviations of chemical shifts from those in other experiments (Fig. 2.14, 2.16) arise from solvent effects...
Figure 2.15. HC HSQC experiment (contour plot) of a-pinene [ CDCI3, 5 % v/v, 25 °C, 125 MHz for C, 500 MHz for h, 4 scans, 256 experiments]. This experiment gives the same information as Fig. 2.14 within 8 minutes instead of two hours required for the CH-COSY in Fig. 2.14 due to higher sensitivity because of proton detection and stronger magnetic field. Deviations of proton shifts from those in Fig. 2.14 arise from the change of the solvent. The methylene protons collapsing in Fig. 2.14 at Sh = 2.19 (200 MHz) display in this experiment an AB system with = 2.17 and Sg = 2.21 (500 MHz)... Figure 2.15. HC HSQC experiment (contour plot) of a-pinene [ CDCI3, 5 % v/v, 25 °C, 125 MHz for C, 500 MHz for h, 4 scans, 256 experiments]. This experiment gives the same information as Fig. 2.14 within 8 minutes instead of two hours required for the CH-COSY in Fig. 2.14 due to higher sensitivity because of proton detection and stronger magnetic field. Deviations of proton shifts from those in Fig. 2.14 arise from the change of the solvent. The methylene protons collapsing in Fig. 2.14 at Sh = 2.19 (200 MHz) display in this experiment an AB system with = 2.17 and Sg = 2.21 (500 MHz)...
Another class of anifacts occurs when scanning vertical or undercut features. As the tip approaches a vertical surface, the side wall may encounter the feature before the end of the tip does. The resulting imj e will appear to contain a discontinuous shift. Changing the angle of the tip with respect to the sample s surface can minimize the problem. Side wall imj ing also occurs in STM, but less frequently since an STM tip has a higher aspect ratio than that of an SFM tip. [Pg.97]

The infrared ellipsometer is a combination of a Fourier-transform spectrometer (FTS) with a photometric ellipsometer. One of the two polarizers (the analyzer) is moved step by step in four or more azimuths, because the spectrum must be constant during the scan of the FTS. From these spectra, the tanf and cosd spectra are calculated. In this instance only A is determined in the range 0-180°, with severely reduced accuracy in the neighborhood of 0° and 180°. This problem can be overcome by using a retarder (compensator) with a phase shift of approximately 90° for a second measurement -cosd and sind are thereby measured independently with the full A information [4.315]. [Pg.269]

Tamayo, J. and Garcia, R., Relationship between phase shift and energy dissipation in tapping-mode scanning force microscopy. Appl Phys. Lett., 73(20), 2926-2928 (1998). Gotsmann, B., Seidel, C., Anezykowski, B. and Fuchs, H., Conservative and dissipative tip-sample interaction forces probed with dynamic AFM. Phys. Rev. B Condens. Matter, 60, 11051-11061 (1999). [Pg.217]

Tire deprotonation of thiazolium salts (see Section II) under argon at room temperature allowed the characterization of nonfused DTDAF of types 52 and 53 by cyclic voltammetry. Their very good donor properties were confirmed by two quasi-reversible peaks of equal intensity (93CC601). It is noteworthy that upon a second scan the first oxidation peak was shifted from -0.03 to -0.04 V. Upon further scans the voltam-mogram remains unchanged. Tliis interesting feature has been observed previously with TTF analogs. It was demonstrated that the neutral form... [Pg.158]

Data collected during these process variable scans indicate that more C02 than expected was being formed (Figure 4). Selectivity to C02 reached a maximum of 5-10% at about 90-95% conversion. At higher conversions, the C02 level is reduced by reverse shift and subsequent methanation of CO or by direct methanation of C02. This selectivity to C02 can be eliminated by cofeeding small amounts of C02 (3-5%). Since multiple C02 absorbers are required in the commercial SNG plant, one or more could be relocated downstream of the methanation step. This could offer some economic advantages since C02 absorption would now occur at higher concentration and pressure and at lower total gas flow. [Pg.165]

Irreversible and Quasi-Reversible Systems For irreversible processes (those with sluggish electron exchange), the individual peaks are reduced in size and widely separated (Figure 2-5, curve A). Totally irreversible systems are characterized by a shift of the peak potential with the scan rate ... [Pg.32]

The chemical shifts are obtained from the spectra of the T1 measurements in relation to the signal for the methyl carbon (20.6 ppm). The T1 measurements were performed using the inversion recovery (IR) method (180 deg. (12.7 us)-tau — 90 deg. (6.1 us)) with MAS 2200 scans were collected and the pulse delay time was veryshort, + 10 sec. [Pg.8]

O charge shifting during exposure for tip/tilt correction or to reduce systematic errors (e.g., nod and shuffle, drift scanning),... [Pg.148]


See other pages where Scan shift is mentioned: [Pg.87]    [Pg.87]    [Pg.220]    [Pg.222]    [Pg.240]    [Pg.538]    [Pg.91]    [Pg.87]    [Pg.87]    [Pg.220]    [Pg.222]    [Pg.240]    [Pg.538]    [Pg.91]    [Pg.1206]    [Pg.280]    [Pg.316]    [Pg.146]    [Pg.281]    [Pg.245]    [Pg.280]    [Pg.149]    [Pg.1015]    [Pg.159]    [Pg.511]    [Pg.712]    [Pg.225]    [Pg.367]    [Pg.384]    [Pg.35]    [Pg.66]    [Pg.135]    [Pg.294]    [Pg.20]   
See also in sourсe #XX -- [ Pg.222 ]




SEARCH



© 2024 chempedia.info