Sampling methods solids

Description of Method. Fluoxetine, whose structure is shown in Figure 12.31a, is another name for the antidepressant drug Prozac. The determination of fluoxetine and its metabolite norfluoxetine. Figure 12.31 b, in serum is an important part of monitoring its therapeutic use. The analysis is complicated by the complex matrix of serum samples. A solid-phase extraction followed by an HPLC analysis using a fluorescence detector provides the necessary selectivity and detection limits. [Pg.588]

Samples will form iTudtiple phases. The laboratory secondary sampling methods must recognize the presence of vapor, liquid, and solid phases. Improper secondaiy sampling methods will result in distorted measurements. These limitations must be clearly communicated to the laboratoiy. [Pg.2559]

Coimnonly used methods for tlie measurement of pestieides in water samples involve. Solid Phase Exttaetion (SPE) followed by Gas Chromatography or High Performanee Liquid Cliromatography (HPLC) analysis. SPE is a multiple step proeedure and, thus, time eonsuming. [Pg.11]

Another method devised for direct sampling of solids involves direct insertion of the sample into the plasma. In this procedure the sample is delivered through the central tube of the torch. The sample may be premixed with graphite powder. [Pg.629]

For on-bead analysis vibrational spectroscopy (IR-spectroscopy) can be employed attenuated total reflection is a method allowing fast and nondestructive on-bead analysis of small samples (single bead analysis) without significant sample preparation. Solid phase NMR is the method of choice if complex structural analysis is intended on the support. Spatially resolved analysis on the resin is possible with microscopic techniques. [Pg.383]

Applications The potential of a variety of direct solid sampling methods for in-polymer additive analysis by GC has been reviewed and critically evaluated, in particular, static and dynamic headspace, solid-phase microextraction and thermal desorption [33]. It has been reported that many more products were identified after SPME-GC-MS than after DHS-GC-MS [35], Off-line use of an amino SPE cartridge for sample cleanup and enrichment, followed by TLC, has allowed detection of 11 synthetic colours in beverage products at sub-ppm level [36], SFE-TLC was also used for the analysis of a vitamin oil mixture [16]. [Pg.433]

In the Wickbold method, solid samples are vaporised in an oxygen stream and fed into an oxyhydrogen flame, which bums in a cooled quartz tube. The combustion products are condensed here, or are captured in an absorption solution as gaseous materials. Although combustion in a Wickbold apparatus is a quick and effective method for destroying organic material of all types, incomplete destruction may occur [19]. In special digestion vessels, known as cold-plasma ashers (CPA),... [Pg.593]

Table 8.34 Requirements of an ideal direct solid sampling method for elemental analysis... Table 8.34 Requirements of an ideal direct solid sampling method for elemental analysis...
Different analytical procedures have been developed for direct atomic spectrometry of solids applicable to inorganic and organic materials in the form of powders, granulate, fibres, foils or sheets. For sample introduction without prior dissolution, a sample can also be suspended in a suitable solvent. Slurry techniques have not been used in relation to polymer/additive analysis. The required amount of sample taken for analysis typically ranges from 0.1 to 10 mg for analyte concentrations in the ppm and ppb range. In direct solid sampling method development, the mass of sample to be used is determined by the sensitivity of the available analytical lines. Physical methods are direct and relative instrumental methods, subjected to matrix-dependent physical and nonspectral interferences. Standard reference samples may be used to compensate for systematic errors. The minimum difficulties cause INAA, SNMS, XRF (for thin samples), TXRF and PIXE. [Pg.626]

New sampling methods are also required for the monitoring of solid samples. The Environmental Specimen Bank (ESB) of Germany has developed devices for sampling suspended particulate matter and sediments. In both purposes, sampling and freezing are carried out in the field. For example, Fig. 15 shows the device used in sediment monitoring [48]. [Pg.405]

Solid samples or solid extracts can be mixed and ground with potassium bromide (KBr),pressed to form a transparent pellet, and a spectrum obtained from the pellet (see C in Figure 14.3). There are gas cells for obtaining spectra of gases and many other methods for obtaining spectra from liquid and solid samples that are not as frequently used as these [13-17],... [Pg.303]

Infrared spectrometry is one of the few analytical techniques that can measure both dissolved and undissolved solids. Thus there are some unique and interesting solid sampling methods. [Pg.225]

Figure 10. Classical adiabatic free energy curve (solid line) forthe Fe /Fe electron transfer at the water/Pt(lll) interface calculated using the Anderson-Newns Hamiltonian and the molecular dynamics umbrella sampling method. Also shown by the dashed line is the parabolic fit of the data. (Reprinted from Ref. 14.)... Figure 10. Classical adiabatic free energy curve (solid line) forthe Fe /Fe electron transfer at the water/Pt(lll) interface calculated using the Anderson-Newns Hamiltonian and the molecular dynamics umbrella sampling method. Also shown by the dashed line is the parabolic fit of the data. (Reprinted from Ref. 14.)...
The earliest applications for quantitative analysis of liquid samples and solid preparations entailed sample dissolution in an appropriate solvent. A number of moisture determinations in APIs and pharmaceutical preparations based on both reflectance and transmission measurements have been reported. Their results are comparable to those of the KF method. The high sensitivity provided by the NIR technique has fostered its use in the determination of moisture in freeze-dried pharmaceuticals. ° The noninvasive nature of NIR has been exploited in determination of moisture in sealed glass vials. " " ... [Pg.480]

Other innovations include PLE, MAE (see Section 1.3.1), and solid-phase microextraction (SPME). SPME is a sampling method applied to GC, HPLC, and CE. It is based on adsorbent- or adsorbent-type fibers and lends itself well to miniaturization. ... [Pg.10]

Removal of metals by immobilized ligands frequently involves a choice of two techniques, a batch method or column chromatography. The batch method can be faster when samples are taken from the supernatant for replicate analyses. This method also can establish when equilibrium (or stasis) has been established. One flaw is that the sample of solid may not be... [Pg.140]


See other pages where Sampling methods solids is mentioned: [Pg.18]    [Pg.418]    [Pg.306]    [Pg.1759]    [Pg.267]    [Pg.254]    [Pg.931]    [Pg.394]    [Pg.422]    [Pg.929]    [Pg.124]    [Pg.617]    [Pg.625]    [Pg.626]    [Pg.637]    [Pg.278]    [Pg.183]    [Pg.257]    [Pg.689]    [Pg.177]    [Pg.28]    [Pg.4]    [Pg.166]    [Pg.339]    [Pg.426]    [Pg.187]    [Pg.31]    [Pg.313]    [Pg.100]    [Pg.296]    [Pg.304]    [Pg.305]    [Pg.306]    [Pg.306]    [Pg.223]   
See also in sourсe #XX -- [ Pg.41 ]