Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Resolvent technique operator

In order to become acquainted with the resolvent technique, and the use of projection operators, we re-examine the problem treated in 1.1. In doing so, we employ the cyclic crystal, which lends itself well to modelling a noninteracting (or unperturbed) substrate (Davison and Styslicka 1996). [Pg.28]

Clearly, the incorporation of the cut and stick tailoring feature of projection operators into the resolvent-technique formulation, makes it a particularly adaptable modelling tool. Moreover, it enables the atomic structure of the geometric space to be reflected in the so-called site representation of the GF. [Pg.34]

However, these formal expressions are of no great help until we know how to operate with the exponential operator, which is very complicated because it involves the full iV-body problem with the interactions between the particles. In order to circumvent this difficulty, we shall use a resolvant technique 89 we define a resolvant operator (L — 2)-1, function of the complex variable z, and write ... [Pg.167]

Chapter 6 deals with fluorescence techniques, with the aim of helping the reader to understand the operating principles of the instrumental set-up he or she utilizes, now or in the future. The section devoted to the sophisticated time-resolved techniques will allow readers to know what they can expect from these techniques, even if they do not yet utilize them. Dialogue with experts in the field, in the course of a collaboration for instance, will be made easier. [Pg.394]

The gas chromatograph (GC) resembles the MS in providing both qualitative and quantitative EGA but is significantly slower in operation. The interval between analyses is normally controlled by the retention time of the last component to be eluted from the column such delay may permit the occurrence of secondary reactions between primary products [162]. Several systems and their applications have been described [144,163— 167] sample withdrawal can be achieved [164] without the necessity for performing the reaction in an atmosphere of carrier gas. By suitable choice of separation column or combination of columns [162], it is possible to resolve species which are difficult to measure in a small low-resolution MS, e.g. H20, NH3, CH4, N2 and CO. Wiedemann [168] has made a critical comparison of results obtained by MS and GC techniques and adjudged the quality of data as being about equal. [Pg.22]

The wavefunction corrections can be obtained similarly through a resolvent operator technique which will be discussed below. The n-th wavefunction correction for the i-th state of the perturbed system can be written in the same marmer as it is customary when developing some scalar perturbation theory scheme by means of a linear combination of the unperturbed state wavefunctions, excluding the i-th unperturbed state. That is ... [Pg.245]

The historical development and elementary operating principles of lasers are briefly summarized. An overview of the characteristics and capabilities of various lasers is provided. Selected applications of lasers to spectroscopic and dynamical problems in chemistry, as well as the role of lasers as effectors of chemical reactivity, are discussed. Studies from these laboratories concerning time-resolved resonance Raman spectroscopy of electronically excited states of metal polypyridine complexes are presented, exemplifying applications of modern laser techniques to problems in inorganic chemistry. [Pg.454]

The m/z values of peptide ions are mathematically derived from the sine wave profile by the performance of a fast Fourier transform operation. Thus, the detection of ions by FTICR is distinct from results from other MS approaches because the peptide ions are detected by their oscillation near the detection plate rather than by collision with a detector. Consequently, masses are resolved only by cyclotron frequency and not in space (sector instruments) or time (TOF analyzers). The magnetic field strength measured in Tesla correlates with the performance properties of FTICR. The instruments are very powerful and provide exquisitely high mass accuracy, mass resolution, and sensitivity—desirable properties in the analysis of complex protein mixtures. FTICR instruments are especially compatible with ESI29 but may also be used with MALDI as an ionization source.30 FTICR requires sophisticated expertise. Nevertheless, this technique is increasingly employed successfully in proteomics studies. [Pg.383]

Optimization is the use of specific methods to determine the most cost-effective and efficient solution to a problem or design for a process. This technique is one of the major quantitative tools in industrial decision making. A wide variety of problems in the design, construction, operation, and analysis of chemical plants (as well as many other industrial processes) can be resolved by optimization. In this chapter we examine the basic characteristics of optimization problems and their solution techniques and describe some typical benefits and applications in the chemical and petroleum industries. [Pg.4]


See other pages where Resolvent technique operator is mentioned: [Pg.167]    [Pg.171]    [Pg.163]    [Pg.20]    [Pg.174]    [Pg.4771]    [Pg.195]    [Pg.108]    [Pg.77]    [Pg.941]    [Pg.332]    [Pg.351]    [Pg.2487]    [Pg.642]    [Pg.459]    [Pg.241]    [Pg.126]    [Pg.217]    [Pg.174]    [Pg.183]    [Pg.58]    [Pg.39]    [Pg.162]    [Pg.9]    [Pg.54]    [Pg.224]    [Pg.410]    [Pg.13]    [Pg.263]    [Pg.327]    [Pg.224]    [Pg.36]    [Pg.14]    [Pg.69]    [Pg.1250]    [Pg.264]    [Pg.179]    [Pg.108]    [Pg.240]    [Pg.399]   
See also in sourсe #XX -- [ Pg.26 ]




SEARCH



Operant techniques

Operator resolving

Resolvant operator

Resolvent operator

Resolvent technique

Resolvent technique projection operators

© 2024 chempedia.info