Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Reproducibility volume measurement

It is seen that in order to measure retention volumes with a precision of 0.1%, the temperature control must be +/- 0.04°C. This level of temperature control on a thermostat bath is not difficult to achieve but it is extremely difficult, if not impossible, to return to a specific temperature to within +/- 0.04°C after prior change. To achieve a precision of retention volume measurement of 1%, the temperature control must be +/- 0.4°C. This is far more practical as most column oven temperature can be set to a given temperature to within +/-0.25°C. Although the data was obtained for three specific solutes, the results can be taken as reasonably representative for all solutes and phase systems. In most practical analyses, the precision limits of retention volume measurement will be about 1% but this will not include the reproducibility of the flow rate given by the pump. As... [Pg.261]

If the total salt content of a solution is high or if only small amounts of sample are available the injection technique may be used. If a piston burette is used for the injection, individual errors cannot be avoided, and reproducibility becomes somewhat poorer than with continuous aspiration. Also, the uncertainty of the volume measurement with small injection volumes becomes noticeable in the reproducibility. In Table 4 the data and statistical values of a simultaneous copper and nickel determination are shown. [Pg.228]

These can be used for both macro and micro volume measurements. The calibration marks on the syringes may not be very accurate, but the reproducibility can be excellent if an automatic deliverer is used, such as a spring-load device that... [Pg.33]

When the model is used to determine the catalyst activity relative to a particular converter using a consistent set of operational data, the aim is reached simply by letting the program find the catalyst aging factors which reproduce the measured catalyst temperatures as accurately as possible. With this method, the numerical integration procedure recycles until, with a suitable integration step, the actual volume of each catalyst bed is reached and the outlet temperature of each bed is equal to the measured value. [Pg.248]

A gas chromatograph with a flame ionization or other detector and a column containing a supported polar liquid phase is used. A reproducible volume of sample is injected. Quantitative results are obtained firom the measured area of the recorded benzene peak by using a ctor obtained firom the analysis of a blend of known benzene content. [Pg.705]

Neumann has adapted the pendant drop experiment (see Section II-7) to measure the surface pressure of insoluble monolayers [70]. By varying the droplet volume with a motor-driven syringe, they measure the surface pressure as a function of area in both expansion and compression. In tests with octadecanol monolayers, they found excellent agreement between axisymmetric drop shape analysis and a conventional film balance. Unlike the Wilhelmy plate and film balance, the pendant drop experiment can be readily adapted to studies in a pressure cell [70]. In studies of the rate dependence of the molecular area at collapse, Neumann and co-workers found more consistent and reproducible results with the actual area at collapse rather than that determined by conventional extrapolation to zero surface pressure [71]. The collapse pressure and shape of the pressure-area isotherm change with the compression rate [72]. [Pg.114]

The concept of equilibrium is central in thermodynamics, for associated with the condition of internal eqmlibrium is the concept of. state. A system has an identifiable, reproducible state when 1 its propei ties, such as temperature T, pressure P, and molar volume are fixed. The concepts oi state a.ndpropeity are again coupled. One can equally well say that the properties of a system are fixed by its state. Although the properties T, P, and V may be detected with measuring instruments, the existence of the primitive thermodynamic properties (see Postulates I and 3 following) is recognized much more indirectly. The number of properties for wdiich values must be specified in order to fix the state of a system depends on the nature of the system and is ultimately determined from experience. [Pg.513]


See other pages where Reproducibility volume measurement is mentioned: [Pg.373]    [Pg.384]    [Pg.241]    [Pg.108]    [Pg.60]    [Pg.260]    [Pg.194]    [Pg.94]    [Pg.108]    [Pg.591]    [Pg.67]    [Pg.126]    [Pg.38]    [Pg.464]    [Pg.95]    [Pg.126]    [Pg.76]    [Pg.92]    [Pg.253]    [Pg.27]    [Pg.951]    [Pg.195]    [Pg.215]    [Pg.5]    [Pg.71]    [Pg.210]    [Pg.379]    [Pg.91]    [Pg.652]    [Pg.1044]    [Pg.56]    [Pg.4]    [Pg.191]    [Pg.529]    [Pg.290]    [Pg.33]    [Pg.458]    [Pg.153]    [Pg.203]    [Pg.546]    [Pg.474]    [Pg.196]    [Pg.1639]   
See also in sourсe #XX -- [ Pg.652 ]




SEARCH



Measure, volume

Measurement reproducibility

Reproducibility

Reproducible

Volume measurable

Volume measurement

Volume reproducibility

© 2024 chempedia.info