Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Purity multiple tests

As discussed in previous sections, many of the currently available studies on 2-hexanone used a single dose level of the test compound, the purity of the test compound was not stated in some studies or in some cases, the purity was stated to be as low as 70%. Therefore little or no dose-response information is available in the existing database. In addition, studies using 2-hexanone of low purity introduce the complications associated with exposures to multiple substances and the potential for chemical interactions. As a result, the available data are limited in their usefulness and must be interpreted with caution. [Pg.48]

Sterilizers and SIP systems in the facility are supplied with steam which upon condensation meets WFI quality requirements (testing steam condensate for microbial content is not fruitful). The steam can be produced directly from the water of sufficient purity to meet the input requirements of the steam generator. Steam generators are phase transition technologies that operate like a still, so it is no more necessary to provide these devices with WFI feed water than it would be to double distill WFI. (Production from WFI is certainly possible, but that is both expensive and an unnecessary precaution.) Modest quantities of steam can be produced from the first effect of a multiple effect WFI still, however, with a resultant loss of WFI output [18]. [Pg.116]

If the system has a spectral detector, spectral evaluation such as peak purity and compound identity should be part of the test. Additional tests should be developed if there are other software functions used in routine analysis, but they are not part of the sample or standard analysis test. If the system is used over a wide concentration range with multiple calibration points, the tests should be run over many concentrations to verify correct function of the calibration curve. [Pg.49]

As the drug discovery process proceeds from early lead discovery through lead optimization and toward candidate selection, the level of purity required of each compound increases. Late-stage compounds may be tested in multiple assays, many of which may involve animal models and may be labor-intensive. Even the best solid phase combinatorial synthesis methods cannot assure that... [Pg.21]

A common test of purity is a pmr spectrum. In a successful test, one structure explains the numbers, multiplicities, relative areas, and chemical shifts of all observed resonances except solvent peaks. To pass the test, all signals predicted for the structure are present and correct in the foregoing respects. [Pg.164]

It has recently been demonstrated, that RP-HPLC coupled with a 96-well plate auto-injector can be utilized for the simultaneous determination of log D, log P and pKa of drug molecules. This method is associated with the following advantages low sample requirement, accommodation of low solubility compounds, less restriction on compound purity, higher throughput, precise data and multiple results in one assay. However, the range in log Poet of the test compounds in the dataset was limited from —1.7 to 4.4. [Pg.198]

Reference material sets which are certified by the International Confederation for Thermal Analysis and Calorimetry (ICTAC) are available through the US National Institute of Standards and Testing (NIST), and are listed in Appendix 2.2. High-purity metals and organic compounds including polymers have been certified. If the standard reference material must be dispensed with a syringe into the sample vessel (for example cyclohexane), care must be taken to ensure that only one droplet is formed in the sample vessel. Multiple transition peaks will be observed if there is more than one droplet present. The transition temperatures listed in Appendix 2.2 are the statistical mean values of measurements made in a number of laboratories and institutes. The ICTAC reference materials are certified for temperature calibration only and not for enthalpy calibration. The reference temperatures in Appendix 2.1 should be used if very accurate calibration of the instrument is required. In order to determine the heat capacity Cp ) of a sample, sapphire (a-alumina, AI2 O3) is used as a standard reference material. The Cp of... [Pg.29]


See other pages where Purity multiple tests is mentioned: [Pg.2]    [Pg.592]    [Pg.212]    [Pg.479]    [Pg.586]    [Pg.224]    [Pg.276]    [Pg.313]    [Pg.283]    [Pg.668]    [Pg.276]    [Pg.409]    [Pg.187]    [Pg.76]    [Pg.32]    [Pg.1331]    [Pg.181]    [Pg.586]    [Pg.810]    [Pg.3642]    [Pg.20]    [Pg.114]    [Pg.487]    [Pg.239]    [Pg.250]    [Pg.198]    [Pg.503]    [Pg.151]    [Pg.25]    [Pg.49]    [Pg.19]    [Pg.177]    [Pg.667]    [Pg.436]    [Pg.194]    [Pg.258]    [Pg.169]    [Pg.25]    [Pg.677]    [Pg.2291]    [Pg.512]    [Pg.32]    [Pg.361]   
See also in sourсe #XX -- [ Pg.163 ]




SEARCH



Multiple testing

Multiple testing multiplicity

Purity tests

© 2024 chempedia.info