Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Probe high resolution

Inc.) wiA a RkP57S probe and a RkP576a probe. High resolution SEM (model S-S20, Hitachi) was used to detem e die size of TiC>2 nanoparticles. [Pg.116]

Several types of Eddy current probes were used with the SQUID system and the commercial system as well. High inductance wire wound probes with a ferritie eore and low induetance planar thick frhn coils were applied. The wire wound probe is the commonly used probe for high resolution conventional testing. The low inductance planar cod is more suited to be apphed in combination with the SQUID system. It is well adapted for surfaee defects and shallow defects. [Pg.301]

Spectroscopic Probes of Cavitation Conditions. Determination of the temperatures reached ia a cavitating bubble has remained a difficult experimental problem. As a spectroscopic probe of the cavitation event, MBSL provides a solution. High resolution MBSL spectra from sUicone oU under Ar have been reported and analy2ed (7). The observed emission comes from excited state has been modeled with synthetic spectra as a... [Pg.260]

One final technical improvement in soHd-state nmr is the use of combined rotational and multiple pulse spectroscopy (CRAMPS) (2), a technique which also requires a special probe and permits the acquisition of high resolution H and X nucleus nmr from soHds. The combination of these methods permits adapting most of the 1-D and 2-D experiments previously described for Hquids to the soHd phase. [Pg.409]

Although x-rays probe inner rather than valence electrons, in light elements the chemical state of the emitting atom may affect inner-shell energies enough to be detected at high resolution. Thus the K d lines of sulfur at 0.537 nm shift by 0.3 pm between the oxidation states and. ... [Pg.320]

Future development of SAM-based analytical technology requires expansion of the size and shape selectivity of template stmctures, as well as introduction of advanced chemical and optical gating mechanisms. An important contribution of SAMs is in miniaturization of analytical instmmentation. This use may in turn have considerable importance in the biomedical analytical area, where miniature analytical probes will be introduced into the body and target-specific organs or even cell clusters. Advances in high resolution spatial patterning of SAMs open the way for such technologies (268,352). [Pg.545]

The three-dimensional, digital nature of SFM and STM data makes the instruments excellent high-resolution profilometers. Like traditional stylus or optical profilometers, scanning probe microscopes provide reliable height information. However, traditional profilometers scan in one dimension only and cannot match SPM s height and lateral resolution. [Pg.92]

The uniqueness and desirability of EELS is realized when it is combined with the power of a TEM or STEM to form an Analytical Electron Microscope (AEM). This combination allows the analyst to perform spatially resolved nondestructive analysis with high-resolution imaging (< 3 A). Thus, not oiJy can the analyst observe the microstructure of interest (see the TEM article) but, by virtue of the focusing ability of the incident beam in the electron microscope, he or she can simultaneously analyze a specific region of interest. Lateral spatial resolutions of regions as small as 10 A in diameter are achievable with appropriate specimens and probe-forming optics in the electron microscope. [Pg.136]

In this chapter, three methods for measuring the frequencies of the vibrations of chemical bonds between atoms in solids are discussed. Two of them, Fourier Transform Infrared Spectroscopy, FTIR, and Raman Spectroscopy, use infrared (IR) radiation as the probe. The third, High-Resolution Electron Enetgy-Loss Spectroscopy, HREELS, uses electron impact. The fourth technique. Nuclear Magnetic Resonance, NMR, is physically unrelated to the other three, involving transitions between different spin states of the atomic nucleus instead of bond vibrational states, but is included here because it provides somewhat similar information on the local bonding arrangement around an atom. [Pg.413]

Concluding this section, two interesting variants of the STM should be addressed. The spin-polarized STM (SPSTM), which works with a ferromagnetic tip, can be used to probe surface magnetism with high resolution [5.47, 5.48]. Other modifications of the STM involve electromagnetic radiation, whereby two basic concepts can... [Pg.289]


See other pages where Probe high resolution is mentioned: [Pg.125]    [Pg.3277]    [Pg.103]    [Pg.88]    [Pg.417]    [Pg.125]    [Pg.3277]    [Pg.103]    [Pg.88]    [Pg.417]    [Pg.303]    [Pg.365]    [Pg.708]    [Pg.711]    [Pg.264]    [Pg.307]    [Pg.938]    [Pg.1243]    [Pg.1474]    [Pg.1474]    [Pg.1625]    [Pg.1630]    [Pg.1630]    [Pg.1715]    [Pg.3000]    [Pg.3000]    [Pg.214]    [Pg.131]    [Pg.321]    [Pg.257]    [Pg.277]    [Pg.73]    [Pg.212]    [Pg.176]    [Pg.1]    [Pg.46]    [Pg.51]    [Pg.128]    [Pg.76]    [Pg.3]    [Pg.54]    [Pg.14]    [Pg.7]    [Pg.22]    [Pg.554]   


SEARCH



High-resolution electric field probe

Probing Supported Metal Catalysts by NMR without Utilizing High-Resolution Techniques

© 2024 chempedia.info