Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pressure and flow consistency

One goal of a bulk delivery system is to provide constant pressure to a CMP polisher, so that the peristaltic metering pump in the polisher can provide constant slurry flow to the polisher platen. While many schemes have been devised to minimize the fluctuations in pressure, there are many [Pg.66]


Initial shock-wave overpressure can be determined from a one-dimensional technique. It consists of using conservation equations for discontinuities through the shock and isentropic flow equations through the rarefaction waves, then matching pressure and flow velocity at the contact surface. This procedure is outlined in Liepmatm and Roshko (1967) for the case of a bursting membrane contained in a shock tube. From this analysis, the initial overpressure at the shock front can be calculated with Eq. (6.3.22). This pressure is not only coupled to the pressure in the sphere, but is also related to the speed of sound and the ratio of specific heats. [Pg.189]

The simulated FBAC consists of an acrylic main reactor (0.5m-H x 0.5m-W x l.Om-L), an air distributor system, particles feeding system including a feed hopper, a discharging sampler, a bag filter for capture of the elutriated fine particles and, pressure and flow rate measurement systems (Fig. 1). The air distributor system has ten air headers. An individual air header is connected with 5 air nozzles and can regulate the airflow rate. The opening ratio of the distributor is 2.1% and each nozzle has four holes for uniform air supply. To measure the pressure fluctuation at an individual air header, high frequency pressure transmitters were mounted at the approach and the exit headers of the FBAC. [Pg.510]

These components guarantee consistency of pressures and flows at any reaction condition independent of the level of conversion. [Pg.410]

The tubule is a spatially extended structure, and it presents both elastic properties and resistance to the fluid flow. The dynamic pressure and flow variations in such a structure can be represented by a set of coupled partial differential equations [11]. An approximate description in terms of ordinary differential equations (a lumped model) consists of an alternating sequence of elastic and resistive elements, and the simplest possible description, which we will adopt here, applies only a single pair of such elements. Hence our model [12] considers the proximal tubule as an elastic structure with little or no flow resistance. The pressure P, in the proximal tubule changes in response to differences between the in- and outgoing fluid flows ... [Pg.321]

Our experiments have shown effects of both pressure and flow on filtration rate. Figure k is a plot of flux versus pressure for an E. coli in AZ broth. Increasing pressure resulted in increasing permeate output. In addition, flux is also related to flow to about 1/3 power. The actual relationships of flux with pressure and flow, however, vary from one system to another and are dependent on the solution consistancy and fouling (which will be discussed). [Pg.63]

Nuvera will design, build, test, and deliver a 15 kilowatt electrical (kWe ) direct current (DC) fuel cell power module that will be specifically designed for stationary power operation using ethanol as a primary fuel. Two PEM fuel cell stacks in parallel will produce 250 amps and 60 volts at rated power. The power module will consist of a fuel processor, carbon monoxide (CO) clean-up, fuel cell, air, fuel, water, and anode exhaust gas management subsystems. A state-of-the-art control system will interface with the power system controller and will control the fuel cell power module under start-up, steady-state, transient, and shutdown operation. Temperature, pressure, and flow sensors will be incorporated in the power module to monitor and control the key system variables under these various operating modes. The power module subsystem will be tested at Nuvera and subsequently be delivered to the Williams Bio-Energy Pekin, Illinois site. [Pg.291]

The automatic control of the pressure and flow-rate of the carrier gas in gas chromatography can be accomplished by using an electronic flow controller such as the Hewlett-Packard HP 5880A. This module (Fig. 12.4) consists of three essential components ... [Pg.360]

The microwave reactor parameters are expected to affect the product distribution and thus, the conditions in Table I will be considered baseline reaction conditions. The absorbed energy is read directly from power monitors and this particular power level was the lowest that provided a consistently stable discharge over an acceptable range of pressures and flow rates. [Pg.298]

The intima consists of a thin monolayer of endothelial cells that line the inner surface of the blood vessel. The endothelial cells have little influence on blood vessel mechanics but do play an important role in hemodynamics and transport phenomena. Because of their anatomical location, these cells are subjected to large variations in stress and strain as a result of pulsatile changes in blood pressure and flow. [Pg.986]

Song and Psaltis [13] offered integrated optofluidic membrane interferometers (OMls) to measure pressure and flow rate by processing the captured images. The OMI consists of two layers of PDMS and flexible air gap between them... [Pg.2830]

The following derivations and calculations avoid any specific assumptions about units. Instead, the quantities have been described as having consistent units. The degree of separation and recovery, moreover, is independent of the units. If, however, numerical values for permeability, pressure, and flow rate are used, then specific units are required, which in turn determine membrane area, given the membrane thickness, or the overall membrane permeability. [Pg.19]

The quality of the water will be controlled by means of pressure and flow meters and by a hardness tester. The hardness tester consists of an automated titration apparatus. The reservoir, with combined titre and indicator solution, should be refilled regularly. [Pg.621]

Liquid chemical feed systems consist of storage tanks (with containment for hazardous chemicals), chemical piping, and metering pumps (with calibration equipment). Control systems monitor the level of chemical in the tanks, pressure and flow in the piping, and pump settings. A schematic of a typical liquid chemical feed system is shown in Figure 7-1. [Pg.76]


See other pages where Pressure and flow consistency is mentioned: [Pg.47]    [Pg.66]    [Pg.47]    [Pg.66]    [Pg.34]    [Pg.1595]    [Pg.45]    [Pg.447]    [Pg.41]    [Pg.198]    [Pg.677]    [Pg.158]    [Pg.476]    [Pg.710]    [Pg.1417]    [Pg.534]    [Pg.1909]    [Pg.2341]    [Pg.322]    [Pg.373]    [Pg.1899]    [Pg.211]    [Pg.109]    [Pg.1599]    [Pg.115]    [Pg.1486]    [Pg.331]    [Pg.55]    [Pg.644]    [Pg.3662]    [Pg.986]    [Pg.90]    [Pg.4]    [Pg.326]   
See also in sourсe #XX -- [ Pg.66 ]




SEARCH



Pressure flow and

© 2024 chempedia.info