Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pressing Apparatus

The hardness test sometimes is performed on the mud as well as the mud filtrate. The mud hardness indicates the amount of calcium suspended in the mud as well as the calcium in solution. This test usually is made on gypsum-treated muds to indicate the amount of excess CaSO present in suspension. To perform the hardness test on mud, a small sample of mud is first diluted to 50 times its original volume with distilled water so that any undissolved calcium or magnesium compounds can go into solution. The mixture then is filtered through hardened filter paper to obtain a clear filtrate. The total hardness of this filtrate then is obtained using the same procedure used for the filtrate from the low-temperature low-pressure API filter press apparatus. [Pg.657]

Piezoelectric measurements in bulk samples can also be made by applying an alternating stress and measuring the charge developed. Recent work in this area has been reported by Damjanovic and co-workers using a dynamic press apparatus [17]. In that work, the importance of measurement frequency and stress amplitude was also clearly pointed out. [Pg.46]

In practice, the high-pressure polycondensation of the salt monomers producing polyimides was carried out by using a piston-cylinder type hot-pressing apparatus with the use of a Teflon capsule as a reaction vessel (see Eq. 5) [34]. [Pg.11]

An intermediate form of isostatic pressure sintering, sometimes referred to as pseudo-isostatic hot-pressing, uses uniaxial hot-pressing apparatus but immerses the object to be sintered in a refractory non-interacting powder within the die and punches. This avoids the very considerable expense of building a furnace inside a thick-walled pressure vessel but the results are inferior to those achieved with true isostatic hot-pressing. [Pg.117]

Filter press Apparatus for filtering, consisting of a number of flat chambers enclosed between sheets of filter cloth (paper or metal) through which the hquids is forced by a pump, leaving the sohd matter in the chambers. [Pg.406]

Figure 4.10 Piston press apparatus for determining consolidation (and filtration) data. To aid correct force transmission to the solid/liquid mixture it is recommended to use a cylinder with a height/diameter aspect ratio of 4 1 or greater. Figure 4.10 Piston press apparatus for determining consolidation (and filtration) data. To aid correct force transmission to the solid/liquid mixture it is recommended to use a cylinder with a height/diameter aspect ratio of 4 1 or greater.
Figure 4.19 shows a schematic representation of state-of-the-art expression apparatus. The more conventional piston press apparatus described in Section 4.5.1 is augmented with the addition of a computer driven pressure regulator which allows the pressure applied to the piston to be carefully controlled and varied according to a preset pattern (e.g. ramp, sinusoidal etc.). The interfaced rotary or linear encoder, force transducer and electronic balance allow semi-continuous measurements of piston displacement, transmitted pressure and... [Pg.195]

This ingot is transformed into a viscous state of approximately 10 —10 Pa s in a special hot-press apparatus (EP 500, Ivoclar Vivadent AG, Liechtenstein). Thereafter, it is pressed at approximately 920°C for 5-15 min to form a glass-ceramic body. This glass-ceramic of the lithium disilicate type does not require additional heat treatment. The glass-ceramic end product contains main crystal phases of Li2Si205 and Li PO. ... [Pg.81]

Figure Bl.7.12. A schematic diagram of a typical selected-ion flow (SIFT) apparatus. (Smith D and Adams N G 1988 The selected ion flow tube (SIFT) studies of ion-neutral reactions Advances in Atomic and Molecular Physics vol 24, ed D Bates and B Bederson p 4. Copyright Academic Press, Inc. Reproduced with pennission.)... Figure Bl.7.12. A schematic diagram of a typical selected-ion flow (SIFT) apparatus. (Smith D and Adams N G 1988 The selected ion flow tube (SIFT) studies of ion-neutral reactions Advances in Atomic and Molecular Physics vol 24, ed D Bates and B Bederson p 4. Copyright Academic Press, Inc. Reproduced with pennission.)...
Figure C3.1.2. Stopped-flow apparatus with motor-driven syringes. Syringe plungers force tire reactants A and B tlirough a mixing chamber into a spectral cell. Kinetic data collection begins when tire effluent syringe plunger is pushed out to contact an activation switch, about a millisecond after tire initiation of mixing. (Adapted from Pilling M J and Seakins P W 1995 Reaction Kinetics (Oxford Oxford University Press)... Figure C3.1.2. Stopped-flow apparatus with motor-driven syringes. Syringe plungers force tire reactants A and B tlirough a mixing chamber into a spectral cell. Kinetic data collection begins when tire effluent syringe plunger is pushed out to contact an activation switch, about a millisecond after tire initiation of mixing. (Adapted from Pilling M J and Seakins P W 1995 Reaction Kinetics (Oxford Oxford University Press)...
Methods for determining fiber-to-fiber friction have been developed (29—31). The friction coefficient can also be measured in terms of the force required to pull entwined fibers apart (32—34) or the force necessary to remove a single fiber from a mass of fibers under pressure (35). Another test involves an apparatus wherein one or a series of parallel fibers are mounted across a small bridge similar to a violin bridge. This is then pressed against a surface that may be another fiber or some other material, and the fibers alternately sHp and stick as they sHde across each other (36,37). [Pg.454]

I. A Victor Meyer Apparatus as shown in Fig. 27. It consists of an elongated glass bulb with a narrow stem, and a capillaiy side-tube. It is provided with a wellfitting rubber cork, which can be pressed easily and tightly into the open end... [Pg.29]

Catalytic combustion experiments have been performed in a flow reactor operating below the lower explosion limits using HC/02/He mixtures. The product analysis was done by gas chromatography. FT-IR spectra have been recorded with a Nicolet Magna 750 instrument, using conventional IR cells connected with evacuation-gas manipulation apparatus. The powder was pressed into self-supporting disks, calcined in air at 773 K and outgassed at 773 K for 20 minutes before experiments. [Pg.484]


See other pages where Pressing Apparatus is mentioned: [Pg.611]    [Pg.100]    [Pg.799]    [Pg.34]    [Pg.262]    [Pg.619]    [Pg.611]    [Pg.416]    [Pg.416]    [Pg.611]    [Pg.100]    [Pg.799]    [Pg.34]    [Pg.262]    [Pg.619]    [Pg.611]    [Pg.416]    [Pg.416]    [Pg.260]    [Pg.438]    [Pg.550]    [Pg.551]    [Pg.552]    [Pg.568]    [Pg.568]    [Pg.1107]    [Pg.217]    [Pg.155]    [Pg.487]    [Pg.173]    [Pg.501]    [Pg.174]    [Pg.95]    [Pg.452]    [Pg.266]    [Pg.1057]    [Pg.48]    [Pg.489]    [Pg.125]    [Pg.475]    [Pg.60]    [Pg.100]    [Pg.550]   


SEARCH



© 2024 chempedia.info