Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polymer software

Several reviews and comparisons of varions models have been published. " hi their recent and more indnstrially oriented review, Bokis et al. mention the UNIFAC, UNIFAC-FV, FH, and SAFT models as the ones currently available in the ASPEN polymer software. Of these, the first... [Pg.706]

The PRDDO (partial retention of diatomic differential overlap) method is an attempt to get the optimal ratio of accuracy to CPU time. It has been parameterized for the periodic elements through Br, including the 3rd row transition metals. It was parameterized to reproduce ah initio results. PRDDO has been used primarily for inorganic compounds, organometallics, solid-state calculations, and polymer modeling. This method has seen less use than other methods of similar accuracy mostly due to the fact that it has not been incorporated into the most widely used semiempirical software. [Pg.36]

The assessment of the contribution of a product to the fire severity and the resulting hazard to people and property combines appropriate product flammabihty data, descriptions of the building and occupants, and computer software that includes the dynamics and chemistry of fires. This type of assessment offers benefits not available from stand-alone test methods quantitative appraisal of the incremental impact on fire safety of changes in a product appraisal of the use of a given material in a number of products and appraisal of the differing impacts of a product in different buildings and occupancies. One method, HAZARD I (11), has been used to determine that several commonly used fire-retardant—polymer systems reduced the overall fire hazard compared to similar nonfire retarded formulations (12). [Pg.451]

With the widespread use of software packages to assist with computational fluid dynamics (CFD) of polymer flow situations, other types of viscosity relationships are also used. For example, the regression equation of Klien takes the form... [Pg.353]

Calibrate the system. Use narrowly dispersed molecular weight standards of the polymer of interest to construct a calibration curve of log molecular weight versus elution volume (Eig. 3.2). If a more sophisticated software system is available, a broad molecular weight standard may be used to calibrate the system. [Pg.78]

Data in this chapter have been processed with CPCwin (Colloid and Polymer Characterization for Windows A.H group, Austria e-mail anton.huber kfuni), a software package that has been developed to handle SEC data. The... [Pg.460]

SEC measurements were made using a Waters Alliance 2690 separation module with a 410 differential refractometer. Typical chromatographic conditions were 30°C, a 0.5-ml/min flow rate, and a detector sensitivity at 4 with a sample injection volume of 80 fil, respectively, for a sample concentration of 0.075%. All or a combination of PEO standards at 0.05% concentration each were used to generate a linear first-order polynomial fit for each run throughout this work. Polymer Laboratories Caliber GPC/SEC software version 6.0 was used for all SEC collection, analysis, and molecular weight distribution overlays. [Pg.502]

The computer has become an accepted part of our daily lives. Computer applications in applied polymer science now are focussing on modelling, simulation, robotics, and expert systems rather than on the traditional subject of laboratory instrument automation and data reduction. The availability of inexpensive computing power and of package software for many applications has allowed the scientist to develop sophisticated applications in many areas without the need for extensive program development. [Pg.3]

Polymer and coating chemists use computer models to predict the properties of formulated products from the characteristics of the raw materials and processing conditions (1, 2). Usually, the chemist supplies the identification and amounts of the materials. The software retrieves raw material property data needed for the modelling calculations from a raw material database. However, the chemist often works with groups of materials that are used as a unit. For instance, intermediates used in multiple products or premixes are themselves formulated products, not raw materials in the sense of being purchased or basic chemical species. Also, some ingredients are often used in constant ratio. In these cases, experimentation and calculation are simplified if the chemist can refer to these sets of materials as a unit, even though the unit may not be part of the raw material database. [Pg.54]


See other pages where Polymer software is mentioned: [Pg.358]    [Pg.358]    [Pg.14]    [Pg.191]    [Pg.315]    [Pg.345]    [Pg.117]    [Pg.201]    [Pg.54]    [Pg.136]    [Pg.201]    [Pg.128]    [Pg.486]    [Pg.524]    [Pg.890]    [Pg.479]    [Pg.498]    [Pg.484]    [Pg.707]    [Pg.604]    [Pg.605]    [Pg.607]    [Pg.610]    [Pg.612]    [Pg.369]    [Pg.198]    [Pg.320]    [Pg.259]    [Pg.210]    [Pg.261]    [Pg.326]    [Pg.333]    [Pg.6]    [Pg.160]    [Pg.163]    [Pg.169]    [Pg.466]    [Pg.469]    [Pg.484]    [Pg.2]    [Pg.113]   
See also in sourсe #XX -- [ Pg.128 ]




SEARCH



© 2024 chempedia.info