Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Platinum detection

L. Rhenus, Rhine) Discovery of rhenium is generally attributed to Noddack, Tacke, and Berg, who announced in 1925 they had detected the element in platinum ore and columbite. They also found the element in gadolinite and molybdenite. By working up 660 kg of molybdenite in 1928 they were able to extract 1 g of rhenium. [Pg.134]

The tetroxide has been used to detect fingerprints and to stain fatty tissue for miscroscope slides. The metal is almost entirely used to produce very hard alloys, with other metals of the platinum group, for fountain pen tips, instrument pivots, phonograph needles, and electrical contacts. [Pg.141]

Fig. 9. Spectral sensitivity of detectors where the detector temperatures in K are in parentheses, and the dashed line represents the theoretical limit at 300 K for a 180° field of view, (a) Detectors from near uv to short wavelength infrared (b) lead salt family of detectors and platinum siUcide (c) detectors used for detection in the mid- and long wavelength infrared. The Hg CdTe, InSb, and PbSnTe operate intrinsically, the doped siUcon is photoconductive, and the GaAs/AlGaAs is a stmctured supedattice and (d) extrinsic germanium detectors showing the six most popular dopants. Fig. 9. Spectral sensitivity of detectors where the detector temperatures in K are in parentheses, and the dashed line represents the theoretical limit at 300 K for a 180° field of view, (a) Detectors from near uv to short wavelength infrared (b) lead salt family of detectors and platinum siUcide (c) detectors used for detection in the mid- and long wavelength infrared. The Hg CdTe, InSb, and PbSnTe operate intrinsically, the doped siUcon is photoconductive, and the GaAs/AlGaAs is a stmctured supedattice and (d) extrinsic germanium detectors showing the six most popular dopants.
Bromine and bromides can be detected quaUtatively by a number of methods. In higher concentrations bromine forms colored solutions in solvents such as carbon tetrachloride [56-23-5] and carbon disulfide [75-15-0]. Bromine reacts with yeUow disodium fluorescein [518-47-8] to form red disodium tetrabromofluorescein (eosin) [548-26-5] C2QH Br4Na20. As Httle as 0.3 p.g of bromide can be detected and chlorides do not interfere (56). Bromine reacts with platinum sulfate [7446-29-9] Pt(S0 2> solution to form red to brown crystals of potassium hexabromoplatinate [16920-93-7] K PtBr ( )-... [Pg.288]

Discussion. Iodine (or tri-iodide ion Ij" = I2 +1-) is readily generated with 100 per cent efficiency by the oxidation of iodide ion at a platinum anode, and can be used for the coulometric titration of antimony (III). The optimum pH is between 7.5 and 8.5, and a complexing agent (e.g. tartrate ion) must be present to prevent hydrolysis and precipitation of the antimony. In solutions more alkaline than pH of about 8.5, disproportionation of iodine to iodide and iodate(I) (hypoiodite) occurs. The reversible character of the iodine-iodide complex renders equivalence point detection easy by both potentiometric and amperometric techniques for macro titrations, the usual visual detection of the end point with starch is possible. [Pg.541]

Apparatus. Use the apparatus shown in Figs. 14.2(a) and (b). The generator cathode (isolated auxiliary electrode) consists of platinum foil (4 cm x 2.5 cm, bent into a half cylinder) and the generator anode (working electrode) is a rectangular platinum foil (4 cm x 2.5 cm). For potentiometric end point detection, use a platinum-foil electrode 1.25 cm x 1.25 cm (or a silver-rod electrode) in combination with an S.C.E. connected to the cell by a potassium chloride- or potassium nitrate-agar bridge. [Pg.541]

If it is desired to use the biamperometric method for detecting the end point, then the calomel electrode and also the silver rod (if used) must be removed and replaced by two platinum plates 1.25 cm x 1.25 cm. The potentiometer (or pH meter) used to measure the e.m.f. must also be removed, and one of the indicator electrodes is then joined to a sensitive galvanometer fitted with a variable shunt. The indicator circuit is completed through a potential divider... [Pg.541]

Apparatus. Set up the apparatus as in Section 14.10 with two small platinum plates connected to apparatus for the amperometric detection of the end point. [Pg.542]

Apparatus. Use the apparatus of Section 14.7. The generator anode is of pure silver foil (3 cm x 3 cm) the cathode in the isolated compartment is a platinum foil (3 cm x 3 cm) bent into a half-cylinder. For the potentiometric end point detection, use a short length of silver wire as the indicator electrode the electrical connection to the saturated calomel reference electrode is made by means of an agar-potassium nitrate bridge. [Pg.544]

In the galvanic detector, the electrochemical detector consists of a noble metal like silver (Ag) or platinum (Pt), and a base metal such as lead (Pb) or tin (Sn), which acts as anode. The well-defined galvanic detector is immersed in the electrolyte solution. Various electrolyte solutions can be used, but commonly they may be a buffered lead acetate, sodium acetate and acetic acid mixture. The chemical reaction in the cathode with electrons generated in the anode may generate a measurable electrical voltage, which is a detectable signal for measurements of DO. The lead is the anode in the electrolyte solution, which is oxidised. Therefore the probe life is dependent on the surface area of the anode. The series of chemical reactions occurring in the cathode and anode is ... [Pg.75]

L. Basini, C.A. Cavalca, and G.L. Haller, Electrochemical Promotion of Oxygen Atom Back-Spillover from Yttria-Stabilized Zirconia onto a Porous Platinum Electrode Detection of SERS Signals,/. Phys. Chem. 98, 10853-10856 (1994). [Pg.276]

Commonly used II-VI compounds include zinc sulfide, zinc selenide, zinc telluride, cadmium sulfide, cadmium telluride, and mercury cadmium telluride. These materials are not as widely used as the III-V compounds, one reason being that it is difficult to achieve p-type doping. Mercury cadmium telluride is used extensively in military night sights, which detect in the 8-13 im spectral band (a similar material, platinum silicide, is being developed for that purpose). The major applications ofCVD II-VI compounds are found in photovoltaic and electroluminescent displays. [Pg.387]

Hydrogenation catalysts,such as platinum, palladium, nickel, and so on. In this case the reaction is the reverse of double-bond hydrogenation (15-11 and 15-15), and presumably the mechanism is also the reverse, though not much is known. Cyclohexene has been detected as an intermediate in the... [Pg.1510]

This Study has shown that reasonably uniform platinum crystallites can be made on y-alumlna, and that platinum and palladium can be segregated and maintained In that form for the most part even after exposure to high temperature oxidation-reduction conditions. Highly dispersed clusters of palladium, nickel, cobalt, and Iron can be observed. Cluster size determination could not be accurately made because of the lack of contrast between the cluster and the support. The marginal detectability by EDS for these clusters enabled elemental Identification to be made, however, mass uniformity determinations could not be made. [Pg.384]

However, no such catalysis was detected. The reason was that even very small amounts of iodide adsorbed on the platinum electrode strongly inhibited the electrochemical reduction of oxygen. A less dramatic but more instructive example was provided by Xiao and Spiro s study of the reaction... [Pg.7]


See other pages where Platinum detection is mentioned: [Pg.433]    [Pg.2175]    [Pg.766]    [Pg.471]    [Pg.433]    [Pg.2175]    [Pg.766]    [Pg.471]    [Pg.439]    [Pg.473]    [Pg.487]    [Pg.365]    [Pg.174]    [Pg.48]    [Pg.103]    [Pg.103]    [Pg.223]    [Pg.212]    [Pg.490]    [Pg.20]    [Pg.141]    [Pg.216]    [Pg.56]    [Pg.200]    [Pg.190]    [Pg.370]    [Pg.151]    [Pg.81]    [Pg.93]    [Pg.117]    [Pg.190]    [Pg.305]    [Pg.486]    [Pg.176]    [Pg.377]    [Pg.377]    [Pg.536]    [Pg.536]   
See also in sourсe #XX -- [ Pg.357 ]




SEARCH



Electrochemical detection platinum-working electrode

© 2024 chempedia.info