Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Support pin

From engineering handbooks we know that a pin supported on one end only will... [Pg.187]

Force (Male Cavity) Guide Pin Bushing Rear Cav. Retainer PI. Push-back Pin Support Plete Ejector Pin Sprue Lock Pin Support Pillar Ejector RetBiner PI. Ejector Plate Clamp Slot Ejector Housing... [Pg.459]

If the product design permits, it can be supported by the mold halves or spider type pin supports that are used to have it floating ... [Pg.472]

S. Helf et al, "Development of an Inspection Method Using a Radioactive Tracer for Detecting the Firing Pin Support in PD Fuze M48A3 , PATR 2030 (June 1954)... [Pg.1058]

Munitions liring-pin support shells, buflci jackets, fuse caps, primers... [Pg.440]

Radioactive Tracer Method for Detecting the Presence of Firing-Pin Supports in Fuze Assemblies (Ref 2)... [Pg.136]

Inspection Method Using a Radioactive Tracer for Detecting the Firing Pin Support in PD Fuze... [Pg.136]

Ejector Pin Sprue Lock Pin Support Pillar Ejector Retainer PI. Ejector Plata Clamp Slot... [Pg.520]

By means of tweezers or long-nose pliers, insert the brass pin supporting the specimen into its receptacle, where it is held by friction. Carefully replace the collimator, being sure not to force it or to drop it. [Pg.511]

The original pin support was poly(acrylic acid) grafted onto inert polyethylene, where the carboxylic acid moieties were capped with mono Boc-protected ethyl-enediamine [79]. PS and the extremely hydrophilic polyhydroxyethyl methacrylate and poly(methacrylic add/dimethylacrylamide) were also grafted on [81]. The last grafted support in the Multipin concept is the so-called Lanterns [80], where the actual solid support is PS, which can be functionalized in a similar way to PS gel-type supports. [Pg.11]

This test method is based on the ASTM E399 [9] for metals but includes certain specific considerations such as a detailed procedure for the determination of for plastics, including specimen preparation details and the correction for the penetration of the loading-pin supports into the specimen. [Pg.536]

Where trunking is installed vertically, the installed conductors must be supported so that the maximum unsupported iength of non-sheathed cabie does not exceed 5 m. Figure 3.52(b) shows cabies woven through insuiated pin supports, which is one method of supporting verticai cabies. [Pg.223]

Ej clor Pin Bpfu Lock Pin Support Pilltr E ctor R i fn r PI. Cj clor Pl to CItmp Slot... [Pg.432]

In the FEM simulations, pinned support (Ux = 0, Uy = 0, and Uz = 0) was assumed at the base of the walls. The Plastic Damage model available in ABAQUS was also adopted in the simulations. The materials used in the walls were concrete (concrete brick tmits) and mortar (head/bed joints between bricks). Both materials have been considered as a continuum media and simulated using the continuum damage model. The only material properties available in (Li et al. 2005) were the concrete and mortar ultimate compression strengths. Other needed data was extracted using ACI formulas. Some of the parameters needed in the Plastic... [Pg.108]

Since there are no external moments applied at the pinned supports, the following reduced stiffness coefficients are used for the columns. [Pg.13]


See other pages where Support pin is mentioned: [Pg.888]    [Pg.893]    [Pg.899]    [Pg.903]    [Pg.229]    [Pg.136]    [Pg.216]    [Pg.637]    [Pg.137]    [Pg.210]    [Pg.505]    [Pg.624]    [Pg.87]    [Pg.102]    [Pg.292]    [Pg.819]    [Pg.322]    [Pg.251]    [Pg.58]    [Pg.2611]    [Pg.39]    [Pg.76]    [Pg.698]    [Pg.701]    [Pg.704]    [Pg.706]   
See also in sourсe #XX -- [ Pg.57 , Pg.617 , Pg.710 ]




SEARCH



Pin, pins

Pinning

© 2024 chempedia.info