Byrd CL, Schwartz SJ, Hedin N (1991) Intravascular techniques for extraction of permanent pacemaker leads. J Tho-rac Cardiovasc Surg 101(6) 989-997... [Pg.34]

Byrd CL, Wilkoff BL, Love CJ et al (1999) Intravascular extraction of problematic or infected permanent pacemaker leads 1994-1996. U.S. Extraction Database, MED Institute. Pacing Clin Electrophysiol 22 1348-1357... [Pg.47]

Kawanishi DT, Brinker JA, Reeves R et al (1998) Kaplan-Meier analysis of freedom from extraction or death in patients with an Accufix J retention wire atrial permanent pacemaker lead a potential management tool. Pacing Clin Electrophysiol 21 2318-2321... [Pg.47]

Kennergren C (1997) Initial European experience with excimer laser assisted extraction of permanent pacemaker leads. Pacing Clin Electrophysiol 20 ""4(Pt. II) 1111 [abstract]... [Pg.113]

Pace IN, Maquilan M, Hessen SE et al (1997) Extraction and replacement of permanent pacemaker leads through occluded vessels use of extraction sheaths as conduits- balloon venoplasty as an adjunct. J Interv Card Electrophysiol 1 271-279... [Pg.146]

Love CJ, Nelson SD, Schaal SF. Extraction of permanent pacemaker leads using the Cook extraction set initial chnical experience. (Abstract) J Am Coll Cardiol 1990 15(2) 50A. [Pg.314]

Byrd CL, Schwartz SJ, Sevina M, et al. Technique for surgical extraction of permanent pacemaker leads and electrodes. J Thorac Cardiovasc Surg 1985 89 142. [Pg.315]

Kennergren C (1999) Excimer laser assisted extraction of permanent pacemaker and ICD leads present experiences of a European multi-centre study. Eur J Cardiothorac Surg 15(6) 856-860... [Pg.80]

The monitoring requirements for endocardial lead extraction are somewhat more demanding than those for a permanent pacemaker procedure. In addition to reliable electrocardiographic monitoring, it is recommended that intra-arterial monitoring also be carried out. This helps to readily detect any sudden change or drop in blood pressure caused by a vascular tear or tamponade. [Pg.271]

The surgical instruments for endocardial lead extraction are identical to those for a permanent pacemaker procedure, which merely requires a minor surgical tray with a limited number of instruments. A standard thoracotomy tray should be readily available in addition to a minor surgical set. A pneumatic thoracotomy saw and/or sternotomy saw should be available in the operating room and even in the catheterization laboratory, in case a thoracotomy or sternotomy is required. Unlike the permanent pacemaker procedure, lead extraction should have a source of reliable suction readily available. [Pg.271]