Performing the Measurement

The next step is to perform the experiments according to the adjusted factor levels and their possible combinations and to record the response variable in which one is interested. [Pg.77]

Measurement no. Depth in cm Location in m Cd concentration (response) found in mg kg 1 [Pg.77]


A wide variety of particle size measurement methods have evolved to meet the almost endless variabiUty of iadustrial needs. For iastance, distinct technologies are requited if in situ analysis is requited, as opposed to sampling and performing the measurement at a later time and/or in a different location. In certain cases, it is necessary to perform the measurement in real time, such as in an on-line appHcation when size information is used for process control (qv), and in other cases, analysis following the completion of the finished product is satisfactory. Some methods rapidly count and measure particles individually other methods measure numerous particles simultaneously. Some methods have been developed or adapted to measure the size distribution of dry or airborne particles, or particles dispersed inhquids. [Pg.130]

Establish when to perform the measurements and what to do if they are not achieved. [Pg.189]

When carrying out quality planning you will be examining intended product characteristics and it is at this stage that you will need to consider how achievement is to be measured and what tool or technique is to be used to perform the measurement. When you have chosen the tool, you need to describe its use in the control plan. [Pg.550]

Returning to the debate over the identity of the carriers in polypyrrole, another major contribution was made by the epr studies of Genoud and colleagues (1985 Devreux et ai> 1987 Nechtschein et ai, 1986) who, in contrast to Scott and colleagues (1983), performed the measurements in situ. [Pg.347]

Fig. 23 a Image of a microfluidic chip used for IFT measurements filled with liquid dye to illuminate channels. To perform the measurement, drops are injected (fluid la and b) are injected into an immiscible stream (2). Additional immiscible matrix is added (3a and 3b) conveying the drops into channel 4 for analysis and measurement. Constrictions in channel 4 accelerate/stretch the drops. Multiple constrictions enable measurement at different interface age. The channel geometry is shown schematically in the inset (from [108]). b Interfacial tension (ct) of water/ethylene glycol mixtures (binary drops) in PDMS oil, as a function of composition ((j)). (Reproduced with permission from [109])... [Pg.99]

Acknowledgements The author would like to thank his former PhD students Th. Koenig, and N. Korner, who both left science long ago for other tasks, for performing the measurements and some of the model calculations presented here. [Pg.146]

The majority of extreme data were received from the universities. It was evident that the switch-on, inject, switch-off approach was applied (likely by the students) without critical evaluation of data produced by the computers software. The least scattered M values were obtained in the industrial laboratories, in which evidently the skilled operators performed the measurements. Better data accuracy was obtained for polyamides [154] and for oligomeric polyepoxides [155] than for the unproblematic poly(dimethyl siloxane)s and even for the most simple polymer, polystyrene likely because only experts measured the latter difficult samples. [Pg.476]

So far presented results are connected with so-called steady-state spectroscopy. Conventionally studied steady state or CW (continuous-wave) liuni-nescence is a process where the excitation sources pump the sample at constant intensity over a time necessary to perform the measurement. The end result is... [Pg.6]

When making a chemical measurement by taking a certain amount of the test material, working it up in a form that can be analyzed, calibrating the instrument, and performing the measurement, analysts understand that there will be some doubt about the result. Contributions to uncertainty derive from each step in the analysis, and even from the basis on which the analysis is carried out. An uncertainty budget documents the history of the assessment... [Pg.161]

To the coordination chemist who wishes to study the electrochemistry of any new complex, water should be the first choice of solvent since it is more convenient to use than any other solvent. The restrictions on the use of water are that the compound must be soluble in water to give a solution of concentration preferably 10-4-10-3 mol dm-3, and also it must not react with water during, at least, the time taken to perform the measurements. [Pg.479]

The variation of solar zenith angle during a spectral measurement may introduce errors in the determination of the calibration factor by altering the shape of the spectrum. This problem can be partly overcome by performing the measurements preferably near the local noon, when the change of solar zenith angle with time is much... [Pg.199]

Performance—The measure of the tower s ability to cool water. It is usually expressed in terms of cooling a quantity of water (gpm) from a specified hot water temperature to a specified cold water temperature at a stated wet-bulb temperature. [Pg.8]

The surface deformation could be reduced even further with intermittent contact SFM. Tapping mode imaging in liquids has been described by several groups [185-191]. The main focus has been put on biological systems such as DNA, cells, chromosomes and proteins. However, it turned out to be rather tricky to perform the measurements. The resonant frequencies were usually 2-5 times lower than in air and the resonant peak gets strongly dampened and broadened [ 192,193]. Because of acoustic excitation of the cantilever holder and the body of fluid, the spectrum can be superimposed by other resonance s which not sensitive to the surface approach and cannot be used for the feedback control [185]. [Pg.93]

Accurate measurement of the equilibrium modulus is extremely difficult because its value remains below the detection limit for a considerable time and, theoretically, an infinite time is required to perform the measurement. [Pg.198]

We acknowledge the assistance of M. Phillips, J. Forrest, and D. Spandau of our group and of Dr. R.W. Stoenner (Chemistry Department, BNL) in performing the measurements reported here. We also acknowledge the Office of Health and Environmental Research,... [Pg.279]

For each image, an oriented lineal analysis was performed. The measurement, P and L, was performed once, at a reference angle of 0 degrees, and an estimate of the porosity computed according to Equation (5). The grid of test lines was then rotated to a new angle and the measurement of PL repeated. By performing this same... [Pg.23]

Collect the field samples and perform the measurements in accordance with the site investigation sampling plan... [Pg.16]


See other pages where Performing the Measurement is mentioned: [Pg.3]    [Pg.410]    [Pg.413]    [Pg.73]    [Pg.22]    [Pg.29]    [Pg.420]    [Pg.379]    [Pg.350]    [Pg.113]    [Pg.133]    [Pg.208]    [Pg.72]    [Pg.291]    [Pg.280]    [Pg.300]    [Pg.64]    [Pg.31]    [Pg.204]    [Pg.115]    [Pg.164]    [Pg.650]    [Pg.150]    [Pg.65]    [Pg.245]    [Pg.193]    [Pg.726]    [Pg.1035]    [Pg.77]    [Pg.182]    [Pg.402]    [Pg.312]   


SEARCH



Measures performance

Performance measurement

Performance measures measurement

Performance, measuring

Performing measurements

The Performance Measurement Process

The problems of SHE performance measurement

The traditional approach to measuring health and safety performance

© 2024 chempedia.info