Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pendant drop method, interfacial surfactant

Interfacial Tension of Aqueous Surfactant Solutions by the Pendant Drop Method... [Pg.329]

The low interfacial tensions between two liquids have been measured for different systems by using the pendant drop method. In the case of the quaternary system Ci2ll25S 3 tNa+H20+n-Butanol+Toluene, the interfacial data as measured by pendant drop method are compared with reported literature data, using other methods (with varying NaCl concentration). In order to understand the role of co-surfactant, ternary systems were also investigated. The pendant drop method was also used for measuring the interfacial tension between surfactant-H20/n-alcohol (with number of carbon atoms in alcohol varying from 4-10). The interfacial tension variation was dependent on both the surfactant and alcohol. [Pg.329]

For each of the three surfactant systems, the interfacial tension values calculated from the I.D.T. traces are higher than their equilibrium counterparts as measured by the pendant drop method. This holds true even when the interface is subject only to displacement, rather than expansion or compression this is shown in Figures 6, 8 and 10, where steady state dynamical interfacial tension values are shown. These values are obtained from the constant linear parts of the I.D.T. traces, or from the last part of the central (small capillary) section of the trace in those cases where it is not certain that the trace had yet reached its plateau (steady state) value. [Pg.514]

Abstract The interfacial properties of tracheal aspirate from infants with untreated neonatal respiratory distress syndrome (NRDS), and NRDS infants after therapy with the exogenous surfactant Curosurf were assessed. The interfacial characteristics of the aspirate (equilibrium surface tension, maximal and minimal surface tension during lateral compression-decompression cycles) were determined with the pendant drop method. Our results show that the tracheal aspirate of infants with untreated NRDS had high equilibrium, maximal and minimal surface tension values. In contrast, the samples from infants, treated with Curosurf , showed lower surface tension values, suggesting that the application of Curosurf improves the composition and the properties of the pulmonary surfactant in the infant lung. [Pg.179]

As preliminary tests to show surfactant properties of asphaltenes were performed interfacial tension measures in a Kriiss Tensiometer DSAIOO using the pendant drop method. The analysis time was 90min and a needle with a diameter of 1.463 mm and a 500pL syringe used. [Pg.21]

The surface tension of the surfactant solutions was measured by the Wil-helmy plate method, whereas the surface tension of the oils was measured by the Du Nouy ring technique on a Krtiss KIOT digital tensiometer. The interfacial tension of the oil-solution interfaces was measured by the pendant drop method. [Pg.475]

The integrated DLS device provides an example of a measurement tool tailored to nano-scale structure determination in fluids, e.g., polymers induced to form specific assemblies in selective solvents. There is, however, a critical need to understand the behavior of polymers and other interfacial modifiers at the interface of immiscible fluids, such as surfactants in oil-water mixtures. Typical measurement methods used to determine the interfacial tension in such mixtures tend to be time-consuming and had been described as a major barrier to systematic surveys of variable space in libraries of interfacial modifiers. Critical information relating to the behavior of such mixtures, for example, in the effective removal of soil from clothing, would be available simply by measuring interfacial tension (ILT ) for immiscible solutions with different droplet sizes, a variable not accessible by drop-volume or pendant drop techniques [107]. [Pg.98]

In order to measure the surface tension of solutions containing surfactants, the maximum bubble pressure, pendant drop and Wilhelmy plate (immersed at a constant depth) methods are suitable capillary rise, ring, mobile Wilhelmy plate, sessile drop and drop weight methods are not very suitable. These methods are not recommended because surfactants preferably adsorb onto the solid surfaces of capillaries, substrates, rings, or plates used during the measurement. In a liquid-liquid system, if an interfacially active surfactant is present, the freshly created interface is not generally in equilibrium with the two immiscible liquids it separates. This interface will achieve its equilibrium state after the redistribution of solute molecules in both phases. Only then can dynamic methods be applied to measure the interfacial tension of these freshly created interfaces. [Pg.249]

In recent years, several theoretical and experimental attempts have been performed to develop methods based on oscillations of supported drops or bubbles. For example, Tian et al. used quadrupole shape oscillations in order to estimate the equilibrium surface tension, Gibbs elasticity, and surface dilational viscosity [203]. Pratt and Thoraval [204] used a pulsed drop rheometer for measurements of the interfacial tension relaxation process of some oil soluble surfactants. The pulsed drop rheometer is based on an instantaneous expansion of a pendant water drop formed at the tip of a capillary in oil. After perturbation an interfacial relaxation sets in. The interfacial pressure decay is followed as a function of time. The oscillating bubble system uses oscillations of a bubble formed at the tip of a capillary. The amplitudes of the bubble area and pressure oscillations are measured to determine the dilational elasticity while the frequency dependence of the phase shift yields the exchange of matter mechanism at the bubble surface [205,206]. [Pg.345]


See other pages where Pendant drop method, interfacial surfactant is mentioned: [Pg.388]    [Pg.340]    [Pg.35]    [Pg.405]   


SEARCH



Drop Method

Pendant drop

Pendant drop method

Pendant drop method, interfacial

Surfactant drop method

Surfactant drops

© 2024 chempedia.info