Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Drop methods

The Direct Current Potential Drop Method for Testing of Powder Metallurgical Parts. [Pg.381]

The Direct Current Potential Drop method (DCPD) has been evaluated for non destructive testing of uniaxially produced Powder Metallurgical (P/M) parts. The aim is to adapt DCPD to be functional as an ndt tool during production of parts. Defects can occur at different stages in the production cycle which means that DCPD has to be performed on components in different states and searching for different defects. [Pg.381]

The following values for the surface tension of a 10 Af solution of sodium oleate at 25°C are reported by various authors (a) by the capillary rise method, y - 43 mN/m (b) by the drop weight method, 7 = 50 mN/m and (c) by the sessile drop method, 7 = 40 mN/m. Explain how these discrepancies might arise. Which value should be the most reliable and why ... [Pg.41]

The principal methods for deterrnination of the deuterium content of hydrogen and water are based upon measurements of density, mass, or infrared spectra. Other methods are based on proton magnetic resonance techniques (77,78), F nuclear magnetic resonance (79), interferometry (80), osmometry (81), nuclear reaction (82), combustion (83), and falling drop methods (84). [Pg.8]

Pressure Drop Methods for estimating fluid-dynamic behavior of crossflow plates are analogous, whether the plates be bubble-cap, sieve, or valve. The total pressure drop across a plate is defined by the general equation (see Fig. 14-29)... [Pg.1376]

Figure 18.4 The hanging-drop method of protein crystallization, (a) About 10 pi of a 10 mg/ml protein solution in a buffer with added precipitant—such as ammonium sulfate, at a concentration below that at which it causes the protein to precipitate—is put on a thin glass plate that is sealed upside down on the top of a small container. In the container there is about 1 ml of concentrated precipitant solution. Equilibrium between the drop and the container is slowly reached through vapor diffusion, the precipitant concentration in the drop is increased by loss of water to the reservoir, and once the saturation point is reached the protein slowly comes out of solution. If other conditions such as pH and temperature are right, protein crystals will occur in the drop, (b) Crystals of recombinant enzyme RuBisCo from Anacystis nidulans formed by the hanging-drop method. (Courtesy of Janet Newman, Uppsala, who produced these crystals.)... Figure 18.4 The hanging-drop method of protein crystallization, (a) About 10 pi of a 10 mg/ml protein solution in a buffer with added precipitant—such as ammonium sulfate, at a concentration below that at which it causes the protein to precipitate—is put on a thin glass plate that is sealed upside down on the top of a small container. In the container there is about 1 ml of concentrated precipitant solution. Equilibrium between the drop and the container is slowly reached through vapor diffusion, the precipitant concentration in the drop is increased by loss of water to the reservoir, and once the saturation point is reached the protein slowly comes out of solution. If other conditions such as pH and temperature are right, protein crystals will occur in the drop, (b) Crystals of recombinant enzyme RuBisCo from Anacystis nidulans formed by the hanging-drop method. (Courtesy of Janet Newman, Uppsala, who produced these crystals.)...
Gaussian 94W provides another quick way of running a job. If an input file has already been prepared, then you can use the drag-and-drop method of running it. It involves these steps (in Windows 3.1) ... [Pg.335]

The most commonly used techniques for contact angle measurements are the sessile drop method and the Wil-helmy plate method. Results obtained from these two methods are in good agreement. [Pg.519]

The AOS and IOS surfactants discussed in this section are laboratory-prepared samples. The experiments were carried out by Borchardt [40] who used the spinning drop method throughout. Experimental details are given in the footnotes of the tables that follow. [Pg.384]

The moving-drop method [2] employs a column of one liquid phase through which drops of a second liquid either rise or fall. The drops are produced at a nozzle situated at one end of the column and collected at the other end. The contact time and size of the drop are measurable. Three regimes of mass transport need to be considered drop formation, free rise (or fall) and drop coalescence. The solution in the liquid column phase or drop phase (after contact) may be analyzed to determine the total mass transferred, which may be related to the interfacial reaction only after mass transfer rates have been determined. [Pg.342]

A growing-drop method has been reported [53] for measuring interfacial liquid-liquid reactions, in which mass transport to the growing drop was considered to be well-defined and calculable. This approach was applied to study the kinetics of the solvent extraction of cupric ions by complexing ligands. [Pg.343]

Recently, Samec et al. [38] have investigated the same system by the video-image pendant drop method. Surface tension data from the two studies are compared in Fig. 2, where the potential scale from the study [36] was shifted so that the positions of the electrocapillary maxima coincide. The systematic difference in the surface tension data of ca. 3%, cf. the dotted line in Fig. 2, was ascribed to the inaccurate determination of the drop volume, which was calculated from the shape of the drop image and used further in the evaluation of the surface tension [38]. A point of interest is the inner-layer potential difference A (pj, which can be evaluated relative to the zero-charge potential difference A cpp c by using Eq. [Pg.426]

For all degrees of peak overlap it is well established that peak height is a more accurate measure of sample size than peak area for symmetrical peaks (277,279). For either method the error increases for disproportionate peak sizes. For tailed peaks errors in either peak height or area can assume large proportions using perpendicular drop method (279,281). In general, the most... [Pg.50]

Figure 3 Protein crystallization diagrammatic representation of the hanging-drop method of vapor diffusion. Figure 3 Protein crystallization diagrammatic representation of the hanging-drop method of vapor diffusion.
The sessile drop method has several drawbacks. Several days elapse between each displacement, and total test times exceeding one month are not uncommon. It can be difficult to determine that the interface has actually advanced across the face of the crystal. Displacement frequency and distance are variable and dependent upon the operator. Tests are conducted on pure mineral surfaces, usually quartz, which does not adequately model the heterogeneous rock surfaces in reservoirs. There is a need for a simple technique that gives reproducible data and can be used to characterize various mineral surfaces. The dynamic Wilhelmy plate technique has such a potential. This paper discusses the dynamic Wilhelmy plate apparatus used to study wetting properties of liquid/liquid/solid systems important to the oil industry. [Pg.560]

Lewis, as already mentioned, used a solution of sodium glycocholate and determined the adsorption of the salt by a surface of paraffin oil. The interfacial tension solution—paraffin oil this was measured for a number of concentrations by the drop method just discussed, and the [Pg.42]

The sources of error indicated above were avoided in a series of experiments carried out by Donnan and Barker, which in principle resemble those made by Lewis, so that only a brief reference to them is necessary. The dissolved substance was nonylic acid, and a drop method. The results could be reproduced with very great accuracy, i.e., to a fraction of one drop in 300—500 drops. Adsorption was produced at a surface air-liquid, air being passed through the solution in bubbles of known size and number, so that the total active surface could be calculated. The bubbles, on reaching the surface, burst, hence the excess of solute carried by them remained in the surface very effective precautions were used to prevent diffusion backwards from this portion into... [Pg.49]


See other pages where Drop methods is mentioned: [Pg.721]    [Pg.27]    [Pg.29]    [Pg.31]    [Pg.238]    [Pg.270]    [Pg.665]    [Pg.375]    [Pg.455]    [Pg.274]    [Pg.1305]    [Pg.199]    [Pg.616]    [Pg.131]    [Pg.346]    [Pg.362]    [Pg.50]    [Pg.17]    [Pg.560]    [Pg.41]    [Pg.74]    [Pg.41]    [Pg.46]    [Pg.406]   
See also in sourсe #XX -- [ Pg.947 ]

See also in sourсe #XX -- [ Pg.22 , Pg.493 ]

See also in sourсe #XX -- [ Pg.493 ]

See also in sourсe #XX -- [ Pg.56 , Pg.57 ]




SEARCH



Advancing/receding contact angles drop method)

Alternative Pressure Drop Method

Bed Pressure Drop Method

Charging voltage drop method

Contact angle sessile drop method

Crystallization method, hanging drop

Drop Volume (Weight) Method

Drop calorimetry method

Drop dimensions method

Drop methods contact angle

Drop methods dynamic surface tension

Drop methods equilibrium surface tension

Drop number method

Drop pressure relaxation method

Drop shape method

Drop shape method and video-image digitization techniques

Drop volume method

Drop volume method accuracy

Drop volume method correction factors

Drop volume method dynamic

Drop weight and volume methods

Drop weight method, surface tension

Drop weight method, surface tension measurement

Drop-casting method

Drop-dry method

Drop-off method

Drop-weight method

Dropping Weight Method

Electrical potential drop method

Expanding drop methods

Falling drop method

Frozen-drop method

Granulation drop formation methods

Growing drop methods

Hanging-drop method

Interfacial tension pendant drop method

Liquid Drop Weight and Shape Method

Liquid drop-weight method

Measurement sessile drop method

Microemulsions spinning drop method

Moving-drop method

Needle-embedded sessile drop method

Ohmic drop method

Oil-drop method

Oscillating drop method

Pendant drop method

Pendant drop method tension

Pendant drop method, interfacial

Pendant drop method, interfacial surfactant

Pendant drop method, surface tension measurement

Pendent drop method

Potential drop method

Potential drop test method

Pressure drop, piplines chart method

Rotating drop method

Sessile Drop or Adhering Gas Bubble Method

Sessile Drop or Bubble Method

Sessile drop method

Sessile drop method, contact angle measurement

Single drop method

Sitting drop method

Softening Point Drop Method

Spherical Si Crystal Fabricated by Drop Tube Method

Spinning drop method

Spinning drop tensiometer method

Spreading drop method

Surface drop method

Surface drop shape methods

Surface force drop weight method

Surface force sessile drop method

Surface force spinning drop method

Surface spinning drop method

Surface tension drop volume method

Surface tension method drop pressure

Surface tension method sessile drop technique

Surface tension pendant drop method

Surface tension spinning drop method

Surfactant drop method

Suspended drop method

Temperature calibration dropping weight method

Test method drop-weight

The Drag and Drop Method

The Drop Volume (Weight) Method

The Drop Weight Method

The Pendant Drop Method

The Spinning Drop Method

The drop methods

The drop-volume method

Wettability sessile drop method

© 2024 chempedia.info