Now, the coupled mass and thermal energy balances can be combined and integrated analytically to obtain a linear relation between temperature and conversion under nonequilibrium (i.e., kinetic) conditions because it is not necessary to consider the temperature and conversion dependence of (Cp mixture)- At high-mass-transfer Peclet numbers, axial diffusion can be neglected relative to convective mass transfer, and the mass balance is expressed in terms of molar flow rate F, and differential volume dV for a gas-phase tubular reactor with one chemical reaction ... [Pg.51]

Dispersion Model An impulse input to a stream flowing through a vessel may spread axially because of a combination of molecular diffusion and eddy currents that together are called dispersion. Mathematically, the process can be represented by Fick s equation with a dispersion coefficient replacing the diffusion coefficient. The dispersion coefficient is associated with a linear dimension L and a linear velocity in the Peclet number, Pe = uL/D. In plug flow, = 0 and Pe oq and in a CSTR, oa and Pe = 0. [Pg.2089]

The dispersion coefficient is orders of magnitude larger than the molecular diffusion coefficient. Some rough correlations of the Peclet number are proposed by Wen (in Petho and Noble, eds.. Residence Time Distribution Theory in Chemical Tngineeiing, Verlag Chemie, 1982), including some for flmdized beds. Those for axial dispersion are ... [Pg.2089]

Axial Dispersion and the Peclet Number Peclet numbers are measures or deviation from phig flow. They may be calculated from residence time distributions found by tracer tests. Their values in trickle beds are fA to Ve, those of flow of liquid alone at the same Reynolds numbers. A correlation by Michell and Furzer (Chem. Eng. /., 4, 53 [1972]) is... [Pg.2121]

Equations 8-148 and 8-149 give the fraction unreacted C /C o for a first order reaction in a closed axial dispersion system. The solution contains the two dimensionless parameters, Np and kf. The Peclet number controls the level of mixing in the system. If Np —> 0 (either small u or large [), diffusion becomes so important that the system acts as a perfect mixer. Therefore,... [Pg.743]

A breakthrough curve with the nonretained compound was carried out to estimate the axial dispersion in the SMB column. A Peclet number of Pe = 000 was found by comparing experimental and simulated results from a model which includes axial dispersion in the interparticle fluid phase, accumulation in both interparticle and intraparticle fluid phases, and assuming that the average pore concentration is equal to the bulk fluid concentration this assumption is justified by the fact that the ratio of time constant for pore diffusion and space time in the column is of the order of 10. ... [Pg.244]

Naturally, there are two more Peclet numbers defined for the transverse direction dispersions. In these ranges of Reynolds number, the Peclet number for transverse mass transfer is 11, but the Peclet number for transverse heat transfer is not well agreed upon (121, 122). None of these dispersions numbers is known in the metal screen bed. A special problem is created in the monolith where transverse dispersion of mass must be zero, and the parallel dispersion of mass can be estimated by the Taylor axial dispersion theory (123). The dispersion of heat would depend principally on the properties of the monolith substrate. Often, these Peclet numbers for individual pellets are replaced by the Bodenstein numbers for the entire bed... [Pg.107]

Glaser and Litt (G4) have proposed, in an extension of the above study, a model for gas-liquid flow through a b d of porous particles. The bed is assumed to consist of two basic structures which influence the fluid flow patterns (1) Void channels external to the packing, with which are associated dead-ended pockets that can hold stagnant pools of liquid and (2) pore channels and pockets, i.e., continuous and dead-ended pockets in the interior of the particles. On this basis, a theoretical model of liquid-phase dispersion in mixed-phase flow is developed. The model uses three bed parameters for the description of axial dispersion (1) Dispersion due to the mixing of streams from various channels of different residence times (2) dispersion from axial diffusion in the void channels and (3) dispersion from diffusion into the pores. The model is not applicable to turbulent flow nor to such low flow rates that molecular diffusion is comparable to Taylor diffusion. The latter region is unlikely to be of practical interest. The model predicts that the reciprocal Peclet number should be directly proportional to nominal liquid velocity, a prediction that has been confirmed by a few determinations of residence-time distribution for a wax desulfurization pilot reactor of 1-in. diameter packed with 10-14 mesh particles. [Pg.99]

The dependence of the local Nusselt number on non-dimensional axial distance is shown in Fig. 4.3a. The dependence of the average Nusselt number on the Reynolds number is presented in Fig. 4.3b. The Nusselt number increased drastically with increasing Re at very low Reynolds numbers, 10 < Re < 100, but this increase became smaller for 100 < Re < 450. Such a behavior was attributed to the effect of axial heat conduction along the tube wall. Figure 4.3c shows the dependence of the relation N /N on the Peclet number Pe, where N- is the power conducted axially in the tube wall, and N is total electrical power supplied to the tube. Comparison between the results presented in Fig. 4.3b and those presented in Fig. 4.3c allows one to conclude that the effect of thermal conduction in the solid wall leads to a decrease in the Nusselt number. This effect decreases with an increase in the... [Pg.150]

The problem of axial conduction in the wall was considered by Petukhov (1967). The parameter used to characterize the effect of axial conduction is P = (l - dyd k2/k ). The numerical calculations performed for q = const, and neglecting the wall thermal resistance in radial direction, showed that axial thermal conduction in the wall does not affect the Nusselt number Nuco. Davis and Gill (1970) considered the problem of axial conduction in the wall with reference to laminar flow between parallel plates with finite conductivity. It was found that the Peclet number, the ratio of thickness of the plates to their length are important dimensionless groups that determine the process of heat transfer. [Pg.171]

The parameter D is known as the axial dispersion coefficient, and the dimensionless number, Pe = uL/D, is the axial Peclet number. It is different than the Peclet number used in Section 9.1. Also, recall that the tube diameter is denoted by df. At high Reynolds numbers, D depends solely on fluctuating velocities in the axial direction. These fluctuating axial velocities cause mixing by a random process that is conceptually similar to molecular diffusion, except that the fluid elements being mixed are much larger than molecules. The same value for D is used for each component in a multicomponent system. [Pg.329]

Water at room temperature is flowing through a 1.0-in i.d. tubular reactor at Re= 1000. What is the minimum tube length needed for the axial dispersion model to provide a reasonable estimate of reactor performance What is the Peclet number at this minimum tube length Why would anyone build such a reactor ... [Pg.346]

Pe, coj, and fio are dimensionless parametas relating to the opoating conditions Pe is Peclet number denoting the inverse of axial mixing intensity, coj denotes the inverse of volumetric loading rate per mass of granules, and ySo daiotes the dimensionless inlet substrate concentration as respectively defined as follows ... [Pg.663]

When a number of competing reactions are involved in a process, and/or when the desired product is obtained at an intermediate stage of a reaction, it is important to keep the residence-time distribution in a reactor as narrow as possible. Usually, a broadening of the residence-time distribution results in a decrease in selectivity for the desired product. Hence, in addition to the pressure drop, the width of the residence-time distribution is an important figure characterizing the performance of a reactor. In order to estimate the axial dispersion in the fixed-bed reactor, the model of Doraiswamy and Sharma was used [117]. This model proposes a relationship between the dispersive Peclet number ... [Pg.35]

The term Lu / D is known as the Peclet number, Pe, and its inverse as the dispersion number. The magnitude of the Peclet number defines the degree of axial mixing in the reactor. [Pg.411]

Use the program to assess the effects of differing degrees of axial dispersion, for values of Peclet number ranging from 0.005 to 0.25. Modify the program to account for zero axial dispersion. [Pg.582]

Data for the bulk fluid, line A, indicate that vz varies as a function of z but maintains a value near 0.75 of maximum velocity. The periodicity of vx and vy is clearly evident in the graph of line A and a 1800 out of phase coupling of the components is seen with one positive when the other is negative. This indicates a preferred orientation to the plane of the oscillatory flow and this feature was seen in all the biofilms grown throughout this study. The secondary flow components are 0.1-0.2 of the maximum axial velocity and are spatially oscillatory. The significant non-axial velocities indicate non-axial mass transport has gone from diffusion dominated, Pe = 0, in the clean capillary, to advection dominated, Pe 2 x 103, due to the impact of the biofilm. For comparison, the axial Peclet number is Pe L 2x 10s. Line B intersects areas covered by biomass and areas of only bulk... [Pg.521]

Equations (8) are based on the assumption of plug flow in each phase but one may take account of any axial mixing in each liquid phase by replacing the molecular thermal conductivities fc, and ku with the effective thermal conductivities /c, eff and kn eff in the definition of the Peclet numbers. The evaluation of these conductivity terms is discussed in Section II,B,1. The wall heat-transfer terms may be defined as... [Pg.24]

For gas-liquid flows in Regime I, the Lockhart and Martinelli analysis described in Section I,B can be used to calculate the pressure drop, phase holdups, hydraulic diameters, and phase Reynolds numbers. Once these quantities are known, the liquid phase may be treated as a single-phase fluid flowing in an open channel, and the liquid-phase wall heat-transfer coefficient and Peclet number may be calculated in the same manner as in Section lI,B,l,a. The gas-phase Reynolds number is always larger than the liquid-phase Reynolds number, and it is probable that the gas phase is well mixed at any axial position therefore, Pei is assumed to be infinite. The dimensionless group M is easily evaluated from the operating conditions and physical properties. [Pg.33]

If the right side of this equation is plotted versus dimensionless time for various values of the group Q)JuL (the reciprocal Peclet number), the types of curves shown in Figure 11.8 are obtained. The skewness of the curve increases with 3) JuL and, for small values of this parameter, the shape approaches that of a normal error curve. In physical terms this implies that when 3JuL is small, the shape of the axial concentration profile does not change... [Pg.399]

The Peclet number for axial dispersion is defined in a manner similar to the radial parameter... [Pg.494]


See other pages where Peclet number axial is mentioned: [Pg.573]    [Pg.285]    [Pg.573]    [Pg.285]    [Pg.34]    [Pg.68]    [Pg.69]    [Pg.618]    [Pg.1446]    [Pg.1652]    [Pg.2068]    [Pg.2121]    [Pg.748]    [Pg.92]    [Pg.107]    [Pg.320]    [Pg.333]    [Pg.336]    [Pg.611]    [Pg.35]    [Pg.42]    [Pg.222]    [Pg.228]    [Pg.243]    [Pg.514]    [Pg.515]    [Pg.32]    [Pg.520]   