Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Packings normal

Investigators of tower packings normally report kcCi values measured at very low inlet-gas concentrations, so that yBM = 1, and at total pressures close to 100 kPa (1 atm). Thus, the correct rate coefficient For use in packed-tower designs involving the use of the driving force y — y /yBM is obtained by multiplying the reported k co values oy the value of pf employed in the actual test unit (e.g., 100 kPa) and not the total pressure of the system to be designed. [Pg.607]

Amine strippers use heat and steam to reverse the chemical reactions with CO2 and H2S. The steam acts as a stripping gas to remove the COo and HjS from the liquid solution and to cairy these gases to the overhead. To promote mixing of the solution and the steam, the stripper is a trayed or packed tower with packing normally used for small diameter columns. [Pg.188]

Fig. 8.36. Per-pass-octanol-conversion for different packings, normalized to 100 g catalyst hold-up plotted over inlet octanol conversion (2 m katapak-S , 2 m monoliths, 1 m DX , 160 °C, 5 barabs, liquid flow 25 kg h-1, countercurrent operation). Fig. 8.36. Per-pass-octanol-conversion for different packings, normalized to 100 g catalyst hold-up plotted over inlet octanol conversion (2 m katapak-S , 2 m monoliths, 1 m DX , 160 °C, 5 barabs, liquid flow 25 kg h-1, countercurrent operation).
Recommendations All existing literature data on gas and liquid holdups for countercurrent flow systems are for packings normally used in absorption towers or gas -liquid reactors. The validity of these data for small packings that would normally be used in gas-liquid-solid catalytic reactions needs to be checked. [Pg.281]

Recommendations As in the case of the holdup, all the data for gas- and liquid-phase axial dispersion coefficients have been obtained for packings normally used for absorption or gas-liquid reaction processes. These packings are large and... [Pg.291]

Recommendations For large packing size, Eq. (8-23) can be used for the estimation of aw or reference can be made to the review by Charpenlier. Future study on this subject should be restricted to the packings normally encountered in gas-liquid-solid catalytic reactors. [Pg.292]

The calculated values are from treatments developed since Bernal and Fowler s qualitative description (199). Those authors gave a hypothetical picture of water as having one of three lattices, depending on the temperature. Below 4°C it is tetrahedrally H bonded in a somewhat irregular tridymite-like structure from 4°C to about 200 C it is tetrahedrally H bonded in an irregular quartz-like lattice, and above 200°C it is a close-packed, normal liquid without appreciable H bond-... [Pg.17]

The way in which these materials change their structures as the anion to cation ratio is varied is of interest. The structures are all variants of the hexagonal wurtzite structure of AIN in which we have alternate sheets of A1 and N atoms packed normal to the hexagonal c-axis. The stacking sequence can be represented by drawing the atom positions on the (110) planes, as all possible atom sites lie on such planes. In... [Pg.141]

A capillary column cannot be packed normally and, in fact, requires no solid support. A dilute solution of the stationary liquid in a volatile solvent is forced into the tube, and the solvent carefully pumped out, leaving a thin layer of liquid on the capillary walls. [Pg.302]

A prototype of a CamCorder equipped with a PEM fuel cell system made of a stack of 15 bipolar plates, as shown in Figure 8-15, was developed to deliver 9 W output power at 8 V. The stack described above was integrated into a housing which also includes the metal hydride reversible hydrogen storage, pressure control, fans, and electronics. This system replaces the Li-ion battery pack normally used as an energy source in the camera. [Pg.159]

As a rule of thumb for particle-packed normal-phase and reversed-phase cartridges, the capacity is approximately 5% of the mass of the packed material. This means that not more than 5 mg of analytes should be applied on a 100 mg packed SPE cartridge. [Pg.168]

Warnock (36) determined TPP in erythrocyte hemolysates by HPLC with precolumn derivatization using alkaline BrCN and fluorescence detection. The stationary phase was Bondapak-NHi and the mobile phase consisted of methanol-100 mM potassium phosphate buffer (pH 7.5) (50 50, v/v). A mean TPP value of 123 27 ng/niL packed normal human erythrocytes was obtained, which is consistent with results obtained previously using an enzymatic method. [Pg.393]

A further modification of the basic cylindrical shape involves installation of a helix inside the cylinder. The interior of this ring may contain a single, a double, or a triple helix. This spiral ring packing normally is made from ceramic and only should be installed by stacking. [Pg.5]


See other pages where Packings normal is mentioned: [Pg.413]    [Pg.119]    [Pg.46]    [Pg.256]    [Pg.119]    [Pg.115]    [Pg.119]    [Pg.81]    [Pg.119]    [Pg.329]    [Pg.135]    [Pg.239]    [Pg.82]    [Pg.14]    [Pg.16]    [Pg.41]    [Pg.69]    [Pg.96]    [Pg.100]    [Pg.133]    [Pg.300]    [Pg.736]    [Pg.47]    [Pg.415]   
See also in sourсe #XX -- [ Pg.134 ]




SEARCH



Normal-phase chromatography column packing

© 2024 chempedia.info